213-00-3417Y2
11/22/2017
Mark Wolters
213-00-3417Y2
ECU to Liquid Single Product_6 sections
Part No:
Description:
Drawn By:
Last Edit
Date:
31
Copyright 2016-2017 SureFire Ag Systems,
Reproduction or other use of drawing
without express written permission from SureFire Ag Systems is forbidden
Revision
A-03
ECU to Liquid Single Product_6 sections
Wire 18AWG
unless otherwise
specified
Ground
12V Sensor Power
BLK 8 AWG
RED 8 AWG
RED
A
Imp Sw
WP TOWER 3-PIN
B
+12V
Imp Height Switch
BLK
RED 14 AWG
BLK 14 AWG
RED 14 AWG
RED 14 AWG
RED 14 AWG
RED 14AWG
25A Fuse
15A Fuse
15A Fuse
RED 14 AWG
RED 14 AWG
RED 14 AWG
BLU
GRN
RED
BLK 14 AWG
RED 14 AWG
BLK
1
2
HC GND
HC PWR
BLK 8 AWG
RED 8 AWG
12 Pin ISO Connector
RED 14 AWG
D-1
C-1
B-1
A-1
BLK 14 AWG
BLK 14 AWG
BLK 14 AWG
BLK 14 AWG
BLK 14 AWG
3
ECU GND
GND
1
2
YEL
4
5
6
7
8
9
10
12
11
ECU Power
ISO CAN Hi
Master Switch
12 V Batt
Power
ISO CAN Lo
Ampseal 16 (Female)
12 Pin, Part# 776437-1
1
2
HC GND
HC PWR
Molex MX (Female), 2 PIN
Part# 19432-0014
POWER CONNECTOR
Molex MX (Male), 2 PIN
Part# 19433-0014
POWER CONNECTOR
1
2
3
4
5
6
7
8
9
10
12
13
14
15
16
17
18
19
20
21
11
Hi GND
Hi GND
Hi Power
15A
Hi Power
15A
ECU Power
Master Switch
Imp Height Switch
ECU Ground
ISO CAN HI
22
23
ISO CAN LO
Hi Power
15A
Hi GND
XA7000-1
GRN
YEL
GRN
BLU
Ampseal 23 Pin
Female Gray
Part# 770680-4
3
ECU GND
GND
1
BLU
2
YEL
4
5
6
7
8
9
10
12
GRN
RED
BLK 14 AWG
RED 14 AWG
BLK
11
ECU Power
ISO CAN Hi
Master Switch
12 V Batt
Power
ISO CAN Lo
Ampseal 16 (Male)
12 Pin, Part# 776438-1
RED 14 AWG
Provide dust cap for Imp Height Switch
C
GND
GRN
RED
BLK
Sensor Return (Gnd)
12 Pin ISO Connector
+12V Sensor
SureFire
Ag
Systems