MAINTENANCE OF THE SYSTEM

Under normal use, this appliance will require only limited cleaning. Constant air flow through this appliance will cause
dust to collect on the burners, base and logs. An excessive build-up of dust can cause the pilot and burners to operate
incorrectly and produce high levels of carbon monoxide, a poisonous gas. This unit should be cleaned about once a
month.

To clean the burner and base, turn the heater OFF and allow the system to cool down. Remove top logs and bottom logs
very carefully. Vacuum or brush away all dust and lint from the system. Do not use any cleaning fluids to clean the logs
or any other part of the appliance.

Replace the logs in their proper position and relight the pilot. At least once a year, the log set and all gas piping should
be checked by a qualified service person.

WARNING

When used without fresh air, appliance may give off 

carbon monoxide

, an odorless, poisonous gas.

OPEN WINDOW AN INCH OR TWO FOR FRESH AIR WHEN USING APPLIANCE

This appliance has a Pilot Light Safety System that turns the appliance off if there is not enough fresh air available.

DO NOT TAMPER WITH THE PILOT LIGHT SAFETY SYSTEM

If appliance shuts off, do not relight until you provide fresh air. If appliance continues to shut off, have it serviced by a
qualified technician. Keep burner and control compartment clean.

CARBON MONOXIDE POISONING MAY LEAD TO DEATH

Early signs of carbon monoxide poisoning resemble the flue, with headache, dizziness and/or nausea. If you experience
any of these symptoms, appliance may not be working properly.

Get fresh air at once!

Have appliance serviced by a

qualified service technician.

Some individuals, pregnant woman, persons with heart or lung disorders, anemia, those under the influence of alcohol
or those at high altitudes are more likely to be affected by carbon monoxide than others.

Due to high temperatures, this appliance must be located out of traffic and away from furniture and draperies.

Adults and especially children should be alerted to the hazard of high surface temperatures and should be kept away to
avoid burns or clothing ignition.

Young children should be carefully supervised when in the same room as the appliance.

Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance.

Do not place clothing or other flammable material on or near the appliance.

Installation and repair should only be performed by a qualified service technician.

The appliance should be inspected before use and at least once a year by a qualified service technician.

More frequent cleaning may be required due to excessive lint from some carpeting, bedding or other materials. It is
imperative that control compartments, burners and circulating air passageways of this appliance be kept clean.

WARNING:

Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns.

WARNING:

Do not use a blower insert, heat exchanger insert of other accessories not approved for use with this heater.

WARNING:

Any change to this appliance or its controls can be dangerous.

Summary of Contents for SCVFMR18

Page 1: ...light any appliance Do not touch any electrical switch Do not use any telephone in your building Immediately call your gas supplier from a neighbor s telephone Follow the gas suppliers instructions If...

Page 2: ...g guide and BTU information BTU Information Set Opening Front Rear Fireplace Natural Gas L P Gas Size Height Width Width Depth Max Min Max Min 18 18 22 18 12 34 000 22 000 34 000 22 000 24 21 18 28 23...

Page 3: ...must be in place when the appliance is operating unless other provisions for combustion air are provided IMPORTANT During the manufacturing process this appliance is treated with certain coloring agen...

Page 4: ...uring any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 PSIG Pressures in excess of 1 2 PSIG will cause damage to the unit FIREPLACE CLEARANCES To guaran...

Page 5: ...olution for leaks Bubbles indicate a leak Repair any leaks and recheck before proceeding DANGER DO NOT USE OPEN FLAME TO TEST FOR LEAKS 2 We suggest you do a test lighting of the burner assembly befor...

Page 6: ...placement can lead to the production of harmful carbon monoxide while the unit is in operation Be sure that the logs are correctly placed in the notches provided for them There should be no direct imp...

Page 7: ...ot use any telephone in your building Immediately call your gas supplier from a neighbors telephone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire departmen...

Page 8: ...may take several attempts and up to 5 minutes to light the pilot the first time since there will be air in the gas line 5 Wait fifteen 15 seconds after pilot is lit before adjusting the flame height 6...

Page 9: ...ears while the hand held unit is learning the code See Fig 13 Remote will return to the off position MANUAL MODE 3 To light the pilot press the following buttons See Fig 14 On Off button ON will start...

Page 10: ...re will start blinking each press lowers the temperature one degree Set button while temperature is still blinking The number of flames automatically adjusts to the correct setting in order to reach t...

Page 11: ...d fuel 6 Use pipe dope on threaded joints of gas piping that is resistant to the action of LP gas 7 Install a manual shut off valve union and 1 8 NPT plugged pressure tap ahead of controls 8 Use soap...

Page 12: ...ith headache dizziness and or nausea If you experience any of these symptoms appliance may not be working properly Get fresh air at once Have appliance serviced by a qualified service technician Some...

Page 13: ...open gas supply valve fully gas line obstruction burner inspection for tube kinks or obstructions inspect burner for dust or debris inspect supply lines for tube kinks or obstructions PARTS LIST Ref P...

Page 14: ...tallation are the expressed responsibility of the purchaser For repair or replacement of a defective part or parts contact our customer service department at 1 800 229 5647 You will be asked to provid...

Page 15: ...15 N NO OT TE ES S...

Reviews: