background image

Specifications

5

VFBC 32, VFBC 36, VFBC 42

Certified To

Design Certified 

Certified To IAS 2-97 Ventless Firebox Enclosures For

Gas Fired Decorative Type Unvented Room Heaters

For use with 

Any ANSI Z21.11.2

Unvented Room Heaters

MODEL

Front Width

(Brick to Brick)

A

Back Width

(Back to Brick)

B

Hearth

Depth

C

VFBC32

26"

(660 mm)

16"

(406 mm)

17"

(432mm)

VFBC36

30"

(762 mm)

20"

(507 mm)

17"

(432mm)

VFBC42 

36"

(915 mm)

26"

(660 mm)

17"

(432mm)

A

B

C

Hearth Dimensions

Fig. 1: Firebox

Internal 
Dimensions

Summary of Contents for CHARLESTON VFBC32

Page 1: ...THIS FIREBOX UNLESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS REQUIRED FOR THE INSTALLATION Homeowner s Installation and Operating Manual Vent Free Universal Firebox model numbers VFBC32 VFBC36 VFBC4...

Page 2: ...onal clearances for firebox size must be followed Refer to the manual that is packed with the log set for operating instructions Table of Contents Safety Information 3 Product Features 4 Hearth Dimens...

Page 3: ...alled Provisions for adequate combustion and ventilation air must be provided See installation guidelines 16 Keep room area clear and free from combustible materials gasoline and other flammable vapor...

Page 4: ...he appliance Do not attempt to install any art of the appliance unless you have all the parts in good condition Make Sure That You Have Received All Parts Check your packing list to verify that all li...

Page 5: ...Decorative Type Unvented Room Heaters For use with Any ANSI Z21 11 2 Unvented Room Heaters MODEL Front Width Brick to Brick A Back Width Back to Brick B Hearth Depth C VFBC32 26 660 mm 16 406 mm 17 4...

Page 6: ...75 43 75 B 24 24 24 C 37 25 41 25 47 25 D 8 5 8 5 8 75 E 38 25 38 25 38 25 F 40 25 40 25 40 25 G 11 11 11 H 20 20 20 I 10 5 10 5 10 5 J 20 24 30 K 21 125 21 125 21 125 L 60 65 625 73 25 M 30 32 875 3...

Page 7: ...line connects to a gas shut off valve recessed flush into the wall or floor The valve should be controlled by a removable valve key for safety An ANSI approved manual shut off valve union and plugged...

Page 8: ...e following instructions must be carefully observed 1 Sidewall Clearances Clearances from the side of the fireplace opening to any combustible wall should not be less that 9 2 Ceiling Clearances The c...

Page 9: ...on operation is done correctly Complete the installation steps in the sequence shown LOCAL BUILDING CODES SHOULD BE CONSULTED IN ALL CASES AS TO THE PARTICULAR REQUIREMENTS CONCERNING THE INSTALLATION...

Page 10: ...ure is insulated and sealed properly you can avoid future cold air problems The time taken to install the firebox correctly is well worthwhile The following steps are to stop potential cold air proble...

Page 11: ...are not to be used with any TYPE or MODEL of glass doors Fireplace screens must be in the closed position across the entire hearth opening prior to the operation of the decorative room heater NOTE Inf...

Page 12: ...t provided 3 Slide the duct over the collar and attach the duct to the collar using the plastic tie straps or three 3 screws screws not provided Continue attaching the ducting together using three 3 s...

Page 13: ...are using wearing proper personal safety devices such as but not limited to gloves safety eye glasses eye protection 3 Check local building codes before installation of the firebox and blower kit 4 Al...

Page 14: ...prices and policies covering replacement parts Parts may be ordered through your Sureheat distributor or dealer You will need the correct name part number and model number of the appliance when order...

Page 15: ...ability of fitness for the purpose and of all other obligations or liabilities Sure Heat Mfg Co does not assume for it any otter obligations or liabilities in connection with the sale or use of the ap...