background image

 

3.  Press or hold 

UP/DOWN

 to change value 

4.  Press 

SELECT

 again or wait 3 seconds to exit this setting 

 

Note 

If  during  the  summer  period  you  find  the  unit  running  late  or  early,  increasing  this  value  will 

prevent the unit from sampling at these times. The default value is 20°C. 
 
 

HEATING AND COOLING 
 

To  provide  cooling  ability  for  those  living  in  tropical  areas,  a  cooling  mode  has  been  provided.  To 
change the controller from heating only to heating and cooling: 
 
1.  Press the 

SELECT

 button until the roof temperature is displayed 

2.  Hold the 

SELECT

 button for 5 seconds until a flashing “H  “ or “HC” is displayed 

3.  “H“ = Heating only. “HC” = heating and cooling. 
4.  Use the 

UP/DOWN

 to change value 

5.  Press 

SELECT

 to exit 

 
Note

  With  cooling  mode  activated,  the  unit  will  operate  at  night  and  the  minimum  roof  setting  is  no 

longer available. 
 
 

CALIBRATION 
 

To adjust the displayed temperature: 
 
1.  While displaying the pool temperature hold the SELECT for 5 seconds 
2.  The display will flash the current temperature. 
3.  Use the 

UP/DOWN

 to adjust the value 

4.  Press the 

SELECT

 button to exit the setting 

 

Note

 The adjustment will not /- 3 degrees 

 

TEMPERATURE SENSOR ERROR INDICATION 
 

If one of the sensor leads is damaged or the sensor is faulty, the appropriate light will flash to indicate 
there is a fault. 
 
      POOL sensor fault 

Pool

 light (green) will flash. 

      ROOF sensor fault 

Roof

 light (red) will flash. 

 
The display will flash (If selected): 
 
“OC”  = Open circuit (Broken wire) 
“SC”  = Short Circuit 
 
 
 
 