The Aqua-Gen 3D is a micro-processor based solar controller used to heat your pool/spa from your 
solar collector. The controller does this by sensing the temperature on the roof and the temperature of 
the  pool.  If  the  roof  temperature  rises  7°C  above  the  pool  temperature  and  the  pool  temperature  is 
below the set point then the controller will switch power to the solar pump which in turn will cycle the 
pool water through the collector to heat the water and then return it to the pool. If the pool temperature 
rises  to  the  set  point  or  the  roof  temperature  falls  to  within  2°C  of  the  pool  water  the  controller  will 
switch power off to the solar pump. 
 

FEATURES 
 

  Sample and hold temperature display 

  Simple one touch control buttons 

  Pool, set point and roof temperature display 

  Winter mode 

  Manual mode 

  Heating and Heating/Cooling Mode 

  Temperature sensor error indication 

 
 
OPERATION 

 

For normal operation

 the controller should be in AUTO mode (indicated by green light). 

 
To test pump

 press the MODE button once (manual is indicated by light). 

 

To change desired pool temperature

 press the SELECT button once. The set (yellow) light should 

be  on  and  the  display  will  indicate  the  set  point,  The  UP/DOWN  buttons  may  now  be  pressed  to 
change the set point. The display will revert back to the pool temperature about 8 seconds after the 
last button was pressed. 

 
To display roof temperature

 press the SELECT button twice. The roof (red) light should be on and 

the  display  will  indicate  the  roof  temperature.  The  display  will  revert  back  to  the  pool  temperature 
about 8 seconds after the last button was pressed. 

 
To activate winter mode

 press the MODE button twice if in AUTO or once if in MANUAL (indicated 

by red light). In this mode the pump will turn on for approximately 10 minutes every day at the time the 
winter mode was activated. If there is a power failure this will reset the 24 hour timer so the pump will 
come on at the time the power is restored. 
 

MINIMUM ROOF SETTING (SAMPLING) 

 
To  prevent  the  unit  from  sampling  at  night  an  adjustable  setting  has  been  provided.  The 

roof

 

temperature needs to be above this value for the unit to sample. To adjust this value: 
 
1.  Press the 

SELECT

 button until the roof temperature is displayed 

2.  Press the 

UP/DOWN 

once to see the value 