Superpro User Manual

Instruction manual

Bedienungsanleitung

Notice d’utilisation

Manuale di Istruzioni

Gebruiksaanwijzing

Bruksanvisning

Instrucciones de uso

Instrukcja obsługi

Ver 1.1.0

GB

Page 1/13

Summary of Contents for Superpro

Page 1: ...Superpro User Manual Instruction manual Bedienungsanleitung Notice d utilisation Manuale di Istruzioni Gebruiksaanwijzing Bruksanvisning Instrucciones de uso Instrukcja obs ugi Ver 1 1 0 GB Page 1 13...

Page 2: ...the Meter 8 Superpro Settings and Menu s 9 MEASURE 9 BATTERY 9 CLEAR AVERAGE 9 CALIBRATION 9 Some more valuable information about the moisture meter 9 Using the averaging facility 9 Battery 10 Storag...

Page 3: ...omplies with EU Directives and standards among other regulations for electrical safety and electromagnetic compatibility Inaccurate usage or handling may however result in damage to the product and sm...

Page 4: ...of ABS plastic Supplied in shockproof carrying case Introduction Thank you for choosing Supertech s Superpro Grain Moisture Analyser This moisture meter is a ground grain meter with built in grinder w...

Page 5: ...9 and 11ml measuring cups Battery Operator s manual Brush for cleaning grinder Shockproof carrying case Part Locator 1 Grinder handle with 9 11ml measuring cups 2 Grinder housing lower grinder cell 3...

Page 6: ...TEST button Select the crop to be tested by using the arrow keys or To select a different crop press the ESC OFF button to return to MEASURE and use arrow keys or to cycle through the options 3 Fill t...

Page 7: ...nt Remnants of sticky or moist material can be removed by grinding a dry grain sample Note When grinding crops with high water content there may be a risk of the two grinder discs touching one another...

Page 8: ...ing grain from the same sample in both cases and adjusted as required Each crop calibration in the meter can if necessary be adjusted individually up or down by up to 3 9 in increments of 0 1 This is...

Page 9: ...pear in the display followed by an automatic return to MEASURE CALIBRATION The calibration menu is used to recalibrate the meter Differing growth factors between years and between varieties can have a...

Page 10: ...the grinder mechanism and lubricate the spindle with a thin layer of non corrosive oil Auto Turn OFF time Setting Our Superpro is pre programmed to Turn OFF after approximately 90 seconds of inactivit...

Page 11: ...ications Measuring range Moisture 5 to 50 Depending on crop type Operating range Temperature 0 to 50 C Resolution 0 1 moisture Temperature compensation Automatic Weight including case 2 kg Dimension 1...

Page 12: ...Failing to meet this requirement can result in heavy metals accumulating in the environment and potentially be damaging towards humans animals and natural resources EU Declaration of Conformity Accor...