Chapter 2: Server Installation
2-5
Installing the Chassis Rails
Position the fixed chassis rail sections you just removed along the side of
the 6024H-82R/6024H-82/6024H-i2 making sure the screw holes line up.
Note that these two rails are left/right specific. Screw the rail securely to
the side of the chassis (see Figure 2-2). Repeat this procedure for the
other rail on the other side of the chassis. You will also need to attach the
rail brackets when installng into a telco rack.
Locking Tabs:
As mentioned, both chassis rails have a locking tab, which
serves two functions. The first is to lock the server into place when
installed and pushed fully into the rack, which is its normal position. Sec-
ondly, these tabs also lock the server in place when fully extended from the
rack. This prevents the server from coming completely out of the rack
when you pull it out for servicing.
Figure 2-2. Installing Chassis Rails