Chapter 7: BIOS
7-15
regulated via CPU Internal Clock modulation when the CPU temperature reaches
the overheat threshold.
C1/C2 Enhanced Mode (Available when supported by the CPU)
Set to Enabled to enable Enhanced Halt State (C1) and Stop Clock State (C2) to
lower CPU voltage/frequency to prevent overheat. The options are Enabled and
Disabled
. Note: please refer to Intel’s web site for detailed information.
Execute Disable Bit (Available when supported by the CPU)
Set to Enabled to allow the processor to classify areas in memory where an ap-
plication code can execute and where it cannot, and thus preventing a worm or a
virus from inserting and creating a fl ood of codes to overwhelm the processor or
damage the system during an attack.
Note: this feature is available when your OS and your CPU support the Execute
Disable Bit function. The options are
Disabled
and Enabled. (For more information
regarding hardware/software support for this function, please refer to Intel's and
Microsoft's web sites.)
Adjacent Cache Line Prefetch (Available when supported by the CPU)
The CPU fetches the cache line for 64 bytes if this option is set to Disabled. The
CPU fetches both cache lines for 128 bytes as comprised if Enabled. The default
settings are
Disabled
for Intel 5100 Series Processors and
Enabled
for 5000
Series Processors.
Hardware Prefetcher (Available when supported by the CPU)
Set to Enabled to activate the hardware components that are used in conjunction
with software programs to prefetch data in order to shorten execution cycles and
maximize data processing effi ciency. The options are Disabled and
Enabled
.
Set Maximum Ext. CPUID=3
When set to Enabled, the Maximum Extended CPUID will be set to 3. The options
are
Disabled
and Enabled.
Direct Cache Access (Available when supported by the CPU)
Set to Enable to route inbound network IO traffi c directly into processor caches
to reduce memory latency and improve network performance. The options are
Disabled
and Enabled.
Summary of Contents for SUPERSERVER 6015W-NT
Page 5: ...v Preface Notes...
Page 67: ...Chapter 6 Advanced Chassis Setup 6 11 Figure 6 6 Removing Replacing the Power Supply...
Page 68: ...6 12 SUPERSERVER 6015W UR 6015W U 6015W NTR 6015W NT User s Manual Notes...
Page 94: ...7 26 SUPERSERVER 6015W UR 6015W U 6015W NTR 6015W NT User s Manual Notes...
Page 100: ...A 6 SUPERSERVER 6015W UR 6015W U 6015W NTR 6015W NT User s Manual Notes...
Page 106: ...B 6 SUPERSERVER 6015W UR 6015W U 6015W NTR 6015W NT User s Manual Notes...