7-20
S
UPER
S
ERVER 6015T-T/6015T-INF User's Manual
Hardware Monitor Logic
(See note on page 7-18.)
CPU Temperature Threshold
This option allows the user to set a CPU temperature threshold that will activate
the alarm system when the CPU temperature reaches this pre-set temperature
threshold. The hardcode default setting is
80
o
C
.
Temperature Monitoring
Highlight this and hit <Enter> to see monitor data for the following items:
CPU1 Temperature/CPU1 Second Core Temperature
CPU2 Temperature/CPU2 Second Core Temperature
PECI Agent 1 Temperature/PECI Agent 2 Temperature/PECI Agent 3 Temperature/
PECI Agent 4 Temperature
System Temperature
Fan1-Fan8 Speeds
: If the feature of Auto Fan Control is enabled, the BIOS will
automatically display the status of the fans indicated in this item.
Fan Speed Control Modes
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase, and vice versa.
Select Workstation if your system is used as a Workstation. Select Server if your
system is used as a Server. Select 3-pin if your chassis uses 3-pin fans. Select
4-pin if your chassis uses 4-pin fans. Select “Disable” to disable the fan speed
control function and allow the onboard fans to constantly run at the full speed (12V).
The Options are:
1. Disable
, 2. Optimized Server w/3-pin, 3. Optimized Workstation
w/3-pin, 4. Optimized Server w/4-pin, and 5. Optimized Workstation w/4-pin.
Voltage Monitoring
The following items will be monitored and displayed:
Vcore A:
Vcore B:
-12V
P1V2_NIC_SEN
+3.3V
+12V
5Vsb
5VDD
P_VTT
Vbat
Summary of Contents for SUPERSERVER 6015T-INF
Page 1: ...SUPER SUPERSERVER 6015T T SUPERSERVER 6015T INF USER S MANUAL Revision 1 0b ...
Page 5: ...v Preface Notes ...
Page 10: ...x Notes SUPERSERVER 6015T T 6015T INF User s Manual ...
Page 18: ...1 8 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...
Page 25: ...Chapter 2 Server Installation 2 7 Figure 2 3 Installing the Server into a Rack ...
Page 27: ...Chapter 2 Server Installation 2 9 Figure 2 4 Accessing the Inside of the System ...
Page 32: ...3 4 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...
Page 62: ...6 6 SUPERSERVER 6015T T 6015T INF User s Manual Figure 6 4 Removing the Power Supply ...
Page 94: ...A 6 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...
Page 100: ...B 6 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...
Page 114: ...D 4 SUPERSERVER 6015T T 6015T INF User s Manual Notes ...