Preface

About this User's Guide

This user's guide is written for system integrators, PC technicians and  
knowledgeable PC users. It provides information for the installation and use of the 
AOC-CTG-i1S add-on card. 

About this Add-on Card

The AOC-CTG-i1S 10 Gigabit Ethernet Adapter is a flexible and scalable Ethernet 

adapter designed for today's demanding data center environments. Based on Intel's 
82599EN 10GbE network controller, the AOC-CTG-i1S addresses the demanding 
needs of next-generation data centers by providing virtualization features, LAN and 

SAN networking flexibility, and proven reliable performance. The AOC-CTG-i1S is 
designed in a small microLP form factor to fit within Supermicro Twin server systems. 

An Important Note to the User

All images and layouts shown in this user's guide are based upon the latest PCB 
Revision available at the time of publishing. The card you have received may or 
may not look exactly the same as the graphics shown in this user's guide.

Returning Merchandise for Service

A receipt or copy of your invoice marked with the date of purchase is required before 
any warranty service will be rendered. You can obtain service by calling your ven-
dor for a Returned Merchandise Authorization (RMA) number. When returning the 
motherboard to the manufacturer, the RMA number should be prominently displayed 
on the outside of the shipping carton, and the shipping package is mailed prepaid 
or hand-carried. Shipping and handling charges will be applied for all orders that 
must be mailed when service is complete. For faster service, You can also request 
a RMA authorization online (http://

www.supermicro.com

). 

This warranty only covers normal consumer use and does not cover damages in-
curred in shipping or from failure due to the alternation, misuse, abuse or improper 
maintenance of products. 

During the warranty period, contact your distributor first for any product problems.  

Preface

iii

Summary of Contents for AOC-CTG-i1S

Page 1: ...User s Guide Revision 1 0 AOC CTG i1S ...

Page 2: ...ILITY OF SUCH DAMAGES IN PARTICULAR SUPER MICRO COMPUTER INC SHALL NOT HAVE LIABILITY FOR ANY HARDWARE SOFTWARE OR DATA STORED OR USED WITH THE PRODUCT INCLUDING THE COSTS OF REPAIRING REPLACING INTEGRATING INSTALLING OR RECOVERING SUCH HARDWARE SOFTWARE OR DATA Any disputes arising between the manufacturer and the customer shall be governed by the laws of Santa Clara County in the State of Califo...

Page 3: ...ime of publishing The card you have received may or may not look exactly the same as the graphics shown in this user s guide Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty service will be rendered You can obtain service by calling your ven dor for a Returned Merchandise Authorization RMA number When returning the...

Page 4: ...d to prevent damage to the system or injury to yourself Warning Important information given to ensure proper system installation or to prevent damage to the components or injury to yourself Note Additional information given to differentiate between various models or provides information for correct system setup Naming Convention SMC Networking Add on Cards ...

Page 5: ...uter B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Asia Pacific Address Super Micro Computer Inc 4F No 232 1 Liancheng Rd Chung Ho Dist New Taipei City 235 Taiwan R O C Tel 886 2 8226 3990 Fax 886 2 8226 3991 Website www ...

Page 6: ...2 2 USB Ports 2 2 SFP Port 2 2 SFP PCB LEDs 2 2 Chapter 3 Installation 3 1 Static Sensitive Devices 3 1 Precautions 3 1 Unpacking 3 1 3 2 Add On Card Brackets 3 2 3 3 Before Installation 3 2 3 4 Installing the Add on Card 3 3 3 5 Installing the Windows Operating System 3 3 3 6 Installing the Linux Operating System 3 4 Build a Binary RPM Package 3 4 3 7 Building the Driver Manually 3 4 AOC CTG i1S ...

Page 7: ...apter 1 2 Key Features The key features of this add on card include the following Single SFP Connector MicroLP form factor PCI Express 2 0 up to 5GT s Intel QuickData Technology VMDq Next Generation VMDq and PC SIG SR IOV for Virtualized Environments Load Balancing on Multiple CPUs iSCSI Remote Boot Support Fibre Channel over Ethernet FCoE Support Support for most Network Operating Systems NOS Sup...

Page 8: ...lowing load balancing between multiple cores CPUs Tx Rx IP SCTP TCP and UDP checksum offloading capabilities IPv4 IPv6 Receive and transmit side scaling for Windows environments and scalable I O for Linux environments Virtualization Features Supports virtualization features such as VMDq Next Generation VMDq 64 queues per port and PC SIG SR IOV implementation IPv6 Offloading Flexible Port Partition...

Page 9: ...l LC fiber optic SR cables up to 300 meters optional SFP transceiver is required Operating Conditions Operating temperature 0 C to 55 C 32 F to 131 F Physical Dimensions Card PCB dimensions without end brackets 12 32cm 4 85in x 3 9cm 1 54in L x W Optional Accessories AOC E10GSFPSR SFP transceiver module for short range fiber cables up to 300m CBL 0347L 1m Twinax copper cable CBL 0348L 3m Twinax co...

Page 10: ...is only available as an integrated solution with Supermicro server systems For the most current product information visit www supermicro com Compliance Environmental RoHS Compliant 6 6 Pb Free Supported Platforms Supermicro Twin Server Systems with microLP expansion slot see table below ...

Page 11: ...1 Add On Card Image and Layout The AOC CTG i1S Image The AOC CTG i1S Layout 1 2 2 Major Components The following major components are installed on the AOC CTG i1S 1 Intel 82599EN 10GbE Controller 2 SFP Port 3 Dual USB 2 0 Ports Intel 82599EN 10GbE Controller 1 2 3 2 3 ...

Page 12: ...layout on Page 2 1 for the location of the SFP port USB Ports Two USB 2 0 ports are located on the add on card Refer to the add on card layout on page 2 1 for the location of the USB ports SFP PCB LEDs There are two link LEDs located on the PCB between the SFP port and the USB ports refer to the add on card layout on Page 2 1 for the location of the LEDs A solid green LED color indicates a connect...

Page 13: ...d by its edges only do not touch its components or peripheral chips Put the add on card back into the antistatic bags when not in use For grounding purposes make sure that your system chassis provides excellent conductivity between the power supply the case the mounting fasteners and the add on card Unpacking The add on card is shipped in antistatic packaging to avoid static damage When unpacking ...

Page 14: ...057L Factory installed I O bracket BKT 0058L Customer installed I O bracket for 2U system For 2U System For 1U System 3 3 Before Installation To install the add on card properly be sure to follow the instructions below 1 Power down the system 2 Remove the power cord from the wall socket 3 Use industry standard anti static equipment such as gloves or wrist strap and follow the instructions listed o...

Page 15: ...required use the screw that you previously removed 5 Attach any necessary external cables to the add on card 6 Replace the chassis cover 7 Plug the power cord into the wall socket and power up the system 3 5 Installing the Windows Operating System Follow the steps below to install the drivers needed for your Windows OS support The controller comes with a driver on the CD ROM CDR NIC 1 Run the CDR ...

Page 16: ...ly the current running kernel MUST match the version and configuration of the installed kernel sources If you have just recompiled the kernel reboot the system at this time 3 7 Building the Driver Manually Follow the instructions below to build the driver manually 1 Move the base driver tar file to the directory of your choice For example home username ixgbe or usr local src ixgbe 2 Untar unzip ar...

Page 17: ...RA DIXGBE_NO_LRO install 5 Load the module For kernel 2 6 x use the modprobe command modprobe ixgbe parameter value For 2 6 kernels the insmod command can be used if the full path to the driver module is specified For example insmod lib modules KERNEL VERSION kernel drivers net ixgbe ixgbe ko In addition when using 2 6 based kernels make sure that older ixgbe drivers are removed from the kernel be...

Page 18: ...3 6 AOC CTG i1S Add on Card User s Guide Notes ...

Page 19: ... expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions ...