background image

3

BEFORE FIRST USE

CHARGE & CALIBRATE BATTERY

MOUNTING

Before first use, the battery must be charged completely.
We also highly recommend that you calibrate it (see page five).

IMPORTANT SECURITY INFORMATION

!

The remote -
charge status display

CHARGER

Slide the mount over the handlebar with the quick-turn-screw facing the rear of the bike and pointing
upwards. Use the rubber shims included if necessary to ensure a tight fit. Tighten the screw enough
that the mount and lamp will sit firmly under vibrations from riding, yet loose enough that the lamp can
be adjusted to shine where intended. Slide the lamp forward onto the mount until you hear a “click” and
the lamp is locked into place. To remove the lamp, push the lever on the mount (below the rear of the
lamp), to the side while pulling the lamp to the rear. For oversize handlebars please use the Supernova
oversize handlebar mount ( article #E778)

The SUPERNOVA charger is integrated in the battery lid. Current is supplied via the adapter or car
adapter (optional). The adapter can be used world-wide between 100 and 240 volts. The car
adapter can only be used with 12 volts (not in trucks with 24 volt batteries!). The charger has a built
in temperature gauge that prohibits charging below 0 degrees Celsius (32F) and above 45
degrees Celsius (113F). When the charger is within the allowed charging temperature range,
charging will occur automatically. Charging is done in two stages. In the first stage, the battery is
charged with maximum current. To prevent damage and ensure a longer life for the battery, the
current intake is reduced while charging the last 15% of the battery. Stage one therefore takes
approximately 2.25 hours to charge the battery to 85% capacity. Stage two takes another 2 hours
to charge the remaining 15%. Basic rule: As long as the battery lid is warm, the battery is still in
charging mode. To get an accurate charge status, connect the battery to the headlight. The
remote lights up in different colors to indicate battery status.

XENON P99-D

SUPERNOVA P99-D

Steady blue light:

Charge status

100%

Flashing blue light:

Charge status 75 - 99%

Flashing green light: Charge status 50 - 75%
Flashing yellow light: Charge status 25 - 50%
Flashing red light:

Charge status

0 - 25%

1. Always pull on the plug directly, never pull the cable.

2. The aluminum lid and adapter can get very warm while charging.

Make sure that the cooling vents are never covered.

3. A temperature gauge prohibits charging outside of a temperature range between

0 degrees Celsius (32F) and 45 degrees Celsius (113F).

4. Unplug lamp when not in use.

5. Do not use lighting system when plug is damaged.

6. Do not tamper with the lighting system. Only SUPERNOVA authorized personnel may open the

lighting system casing.

7. Only use 12 volts with the optional car adapter - never 24 volts (trucks for example).

6

4

REMOTE CONTROL

STROBOSKOPFUNKTION / SOS - ZEICHEN

SWITCHOFF

2s

=ON

S

+

A key-lock ensures that the lighting system is not
turned on involuntarily.

Press button # 2 and then button # 1 in quick
succession to make lamp 1 light up at the
highest energy level. Press button #1
and then button #2 to light up lamp 2 first.

Please note! You need to wait for approx.
5 seconds before switching on the second lamp.
Only press the second button shortly!
If lamp 2 does not ignite, press again (shortly).

To turn off lamp 1, please press button
# 1 for about 2 seconds.
To turn off lamp 2, please press button
# 2 for about 2 seconds. K

o turn off the other lamp as well.

eep pressing

any of the buttons t

SWITCHON

S

BULB #1

OFF

S

Both bulbs can be dimmed:

Bulb #1 with button #1

Bulb #2 with button #2

When both bulbs are on,
the lights will be dimmed together.

LIGHTINGLEVELS

Explanations:

S

=

PRESS SHORTLY

2s

=

PRESS BUTTON FOR 2 SECONDS

The life span of your Xenon bulbs will be shortened by frequent lightings, not by the overall burn time!
We do not recommend turning your lamp on and off very frequently.
The switch to energy saving mode does not effect the lifespan of the bulb.

ADDITIONAL INFORMATION

2s

BULB #2

OFF

S

BULB #1

OFF

Dim
BULB #1

Dim
BULB #2

XENON P99-D

SUPERNOVA P99-D

Summary of Contents for P99-D

Page 1: ... battery 85 in 1 5 h 100 in 2 25 h XENON P99 D 2 IMPORTANT SAFETY FEATURES EXTREMELY BRIGHT OTHER IMPORTANT SAFETY INFORMATION SUPERNOVA P99 D Reduce your speed when the red LED starts flashing Be prepared that the light will automatically turn off Lighting periods listed here are approximations and may vary with the age and temperature of the battery This lighting system is completely sealed and ...

Page 2: ...t The remotelightsup indifferentcolorstoindicatebatterystatus XENON P99 D SUPERNOVA P99 D Steady blue light Charge status 100 Flashing blue light Charge status 75 99 Flashing green light Charge status 50 75 Flashing yellow light Charge status 25 50 Flashing red light Charge status 0 25 1 Always pull on the plug directly never pull the cable 2 The aluminum lid and adapter can get very warm while ch...

Page 3: ...eryissealedandshouldneverbeopened Moreatwww supernova lights com 6 5 1s BURN TIME INDICATOR BATTERY FUEL GAUGE Time remaining at a particular power setting can be displayed by pushing button 2 for one whole second Example Flashing white light displays hours flashing green light displays minutes in 15 minute increments The light flashes white twice then green three times Time remaining is 2 hours 4...

Page 4: ...onal Article E808 LAMP CANNOT BE TURNED ON SUPERNOVA P99 D The Supernova lithium ion battery is extremely low maintenance The revolutionary charging technology with its intelligent temperature monitoring system always charges the battery perfectly Two electronic safety systems ensure an excellent deep discharge protection There are however some additional points toconsiderif youwanttooptimizetheli...

Reviews: