Appendix B: Software Installation Instructions
B-11
Adding/Deleting Hotspares
(*Note: In order to rebuild a RAID (RAID 0 or RAID 1), you would need to
add a new HDD as a hotspare.)
1.
Turn on your computer and press Ctrl+A as prompted to access the ARC
Utility.
2. From the ARC menu, select Array Configuration Utility (ACU).
3. From the ACU menu, select Add/Delete Hotspares.
4. Use the up and down arrow keys to highlight and select the disk you
want to designate as a hotspare, and press <Insert>, and then, press
<Enter>.
5. Press yes when the following prompt is displayed:
"Do you want to create spare?" (Yes/No?)
The spare you have selected will appear in the Select Drive Menu.