Chapter 3: Maintenance and Component Installation
Air Shroud for Power
One additional air shroud is used to cool the power supply connection area in the system
(see figure below).
Caution:
DO NOT perform this service with the system mounted inside the rack.
1. Power down the system as described in Section 3.1.
2. Remove the system from the rack and place it on a bench, then remove the cover as
described
3. Place the air shroud over the power supply connectors and secure with the screws and
double-sided tape included with the air shroud, as illustrated below.
4. Close the cover and push the system back into the rack.
Figure 3-10. Installing Air Shrouds for the Power Connections
Caution:
The handles used for pulling the system from the rack are not intended to be used
to pick up or lift the system.