6-4
SUPERSERVER 8048B-TR4F/C0R4FT User's Manual
Figure 6-4: Chassis Storage Module
Rotating the Storage Module for Rack Mounting
1. Open the chassis cover.
2. Locate the storage module and disconnect any cables from the storage
module to any component in the chassis.
3. Push the storage module release lever. This lever unlocks the storage
module.
4. Grasp the external edges of the storage module and pull the unit from the
chassis.
5. Rotate the storage module 90 degrees (as illustrated in Figure 6-5).
6. Reinsert the module into the chassis and reconnect the cords.
Caution:
All of the drive carriers must remain in the drive bays to maintain proper
cooling air
fl
ow.