Chapter 7: BIOS
7-11
Hardware Health Confi guration
This feature allows the AMI BIOS to automatically display the status of the follow-
ing items:
Temperatures
CPU Overheat Temperature
This feature allows the user to set the CPU Overheat temperature threshold. The
options range from 65
o
C to 90
o
C. Use the <+> and <-> keys to set the desired
setting. The default setting is
78
o
C
.
The AMI BIOS will automatically monitor and display the following information:
CPU1 Temperature, CPU2 Temperature, CPU3 Temperature, CPU4 Tempera-
ture and System Temperature
Fan Speed
Fan Speed Control:
This feature allows the user to decide how the system controls the speeds of the
onboard fans. The CPU temperature and the fan speed are correlative. When the
CPU on-die temperature increases, the fan speed will also increase, and vice versa.
Select “Workstation” if your system is used as a workstation. Select “Server” if your
system is used as a server. Select “Disable” to disable the fan speed control func-
tion to allow the onboard fans to constantly run at full speed (12V). The options
are
Disable
, 3-pin (Server), and 3-pin (Workstation).
Fan1-Fan9 Speeds
Voltage
Voltage Monitoring
CPU1-CPU4 Vcore
+3.3V,
+5V,
+12Vcc,
-12Vcc,
+3.3V Standby
Summary of Contents for SUPERSERVER 8044T-8R
Page 1: ...SUPERSERVER 8044T 8R SUPER USER S MANUAL 1 0...
Page 5: ...v Preface Notes...
Page 10: ...Notes x SUPERSERVER 8044T 8R User s Manual...
Page 26: ...2 10 SUPERSERVER 8044T 8R User s Manual Figure 2 5 Accessing the Inside of the System...
Page 30: ...3 4 8044T 8R User s Manual Notes...
Page 58: ...5 24 SUPERSERVER 8044T 8R User s Manual Notes...
Page 68: ...6 10 SUPERSERVER 8044T 8R User s Manual Figure 6 8 Removing a Power Supply Module...
Page 90: ...A 2 SUPERSERVER 8044T 8R User s Manual Notes...
Page 98: ...B 8 SUPERSERVER 8044T 8R User s Manual Notes...
Page 102: ...C 4 SUPERSERVER 8044T 8R User s Manual Notes...