System Fans
Four fans provide cooling. Fan speed is controlled by a system temperature setting in IPMI.
If a fan fails, the remaining fans will ramp up to full speed. The system can continue to run
with a failed fan. Replace any failed fan at your earliest convenience with the same type and
model.
Figure 3-15. Fan Housing Placement
Changing a System Fan
1. Determine which fan is failing. If possible, use IPMI. If not, remove the chassis cover
while the power is on, and examine the fans to determine which one has failed.
2. Remove power from the system as described in Section 3.1.
3.
Remove the fan cable from the backplane for the failed fan and the adjacent fan.
4. Lift the fan housing up and out of the chassis.
5. Push the fan up from the bottom and out of the top of the housing.
Two Fans Cooling
Node A and B
Two Fans Cooling
Node C and D