background image

Chapter 4: System Safety

4-3

4-3 ESD 

Precautions

Electrostatic discharge (ESD) is generated by two objects with different electrical 

charges coming into contact with each other.  An electrical discharge is created to 

neutralize this difference, which can damage electronic com ponents and printed 

circuit boards. The following measures are generally suffi cient to neutralize this 

difference before contact is made to protect your equipment from ESD:

Use a grounded wrist strap designed to prevent static discharge.

Keep all components and printed circuit boards (PCBs) in their antistatic bags 

until ready for use.

Touch a grounded metal object before removing the board from the antistatic 

bag.

Do not let components or PCBs come into contact with your clothing, which may 

retain a charge even if you are wearing a wrist strap.

Handle a board by its edges only; do not touch its components, peripheral chips, 

memory modules or contacts.

When handling chips or modules, avoid touching their pins.

Put the serverboard and peripherals back into their antistatic bags when not 

in use.

For grounding purposes, make sure your computer chassis provides excellent 

conductivity between the power supply, the case, the mounting fasteners and 

the serverboard.

!

After accessing the inside of the system, close the system back up and secure 

it to the rack unit after ensuring that all connections have been made.

Summary of Contents for SUPERSERVER 6025W-UR

Page 1: ...SUPERSERVER 6025W UR SUPER USER S MANUAL 1 0...

Page 2: ...r the resolution of any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to com...

Page 3: ...hapter 1 Introduction The rst chapter provides a checklist of the main components included with the server system and describes the main features of the X7DWU serverboard and the SC825TQ R700U chassis...

Page 4: ...to this chapter when adding or removing processors or main memory and when recon guring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed information on the SC825TQ R700...

Page 5: ...v Preface Notes...

Page 6: ...plane 1 5 Cooling System 1 5 1 4 Contacting Supermicro 1 6 Chapter 2 Server Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 Rack Pr...

Page 7: ...Safety Precautions 4 1 4 2 General Safety Precautions 4 2 4 3 ESD Precautions 4 3 4 4 Operating Precautions 4 4 Chapter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions 5 1 Un...

Page 8: ...e 6 3 6 4 Drive Bay Installation Removal 6 4 Accessing the Drive Bays 6 4 SAS SATA Drive Installation 6 5 Hard Drive Backplane 6 6 IDE and Floppy Drive Installation 6 6 Air Shroud 6 9 6 5 Power Supply...

Page 9: ...perServer 6025W UR as listed below Three 3 8 cm hot swap chassis fans FAN 0094L One 1 air shroud MCP 310 00022 00 Two 2 CPU passive heatsinks SNK P0025P One 1 DVD ROM drive DVM PNSC 824V Two 2 3 5 dum...

Page 10: ...airs Please refer to Chapter 5 for memory speed jumper settings UIO The X7DWU is a specially designed serverboard that features Supermicro s UIO Universal I O technology UIO serverboards have a PCI Ex...

Page 11: ...r onboard features that promote system health include onboard voltage moni tors a chassis intrusion header auto switching voltage regulators chassis and CPU overheat sensors virus protection and BIOS...

Page 12: ...support to enable the hot swap capability of the Serial ATA drives PCI Expansion Slots When con gured as a 6025W UR server the SC825TQ R700U suppports expan sion cards on both the left and right sides...

Page 13: ...VGA port two USB 2 0 ports PS 2 mouse and keyboard ports and two gigabit Ethernet ports Cooling System The SC825TQ R700U chassis has an innovative cooling design that includes three 8 cm hot plug syst...

Page 14: ...ress Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Te...

Page 15: ...e location for the rack unit that will hold the SuperServer 6025W UR It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic...

Page 16: ...ck installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or mor...

Page 17: ...hat the amount of air ow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a rack so that a hazardous condition does not arise due to uneven mechanical...

Page 18: ...ttached to the front of the chassis and which gets attached to the rear of the chassis The longer of the two is the front section The third rail section attaches to the rack Installing the Chassis Rai...

Page 19: ...Chapter 2 Server Installation 2 5 Figure 2 1 Installing Chassis Rails...

Page 20: ...on both sides you may have to depress the locking tabs when inserting See Figure 2 2 When the server has been pushed completely into the rack you should hear the locking tabs click 2 5 Checking the S...

Page 21: ...Chapter 2 Server Installation 2 7 Figure 2 2 Installing the Server into a Rack...

Page 22: ...op chassis cover A slim DVD ROM drive should be preinstalled in your server Refer to Chapter 6 if you need to install an optional slim oppy disk drive to the system Depending upon your system s con gu...

Page 23: ...Chapter 2 Server Installation 2 9 Figure 2 3 Accessing the Inside of the System...

Page 24: ...2 10 SUPERSERVER 6025W UR User s Manual Notes...

Page 25: ...of speci c components There are also two buttons on the chassis control panel 3 2 Control Panel Buttons The two push buttons located on the front of the chassis are a reset button and a power on off b...

Page 26: ...placing the power supply This LED should be off when the system is operating normally Overheat Fan Fail When this LED ashes it indicates a fan failure When on continuously it indicates an overheat con...

Page 27: ...ives Green Each drive carrier has a green LED When illuminated this green LED on the front of the drive carrier indicates drive activity A connection to the SAS SATA backplane enables this LED to blin...

Page 28: ...SUPERSERVER 6025W UR User s Manual 3 4 Notes...

Page 29: ...ower you should rst power down the system with the operating system rst and then unplug the power cords of all the power supply units in the system When working around exposed electrical circuits anot...

Page 30: ...body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Serverboard Battery CAUTION...

Page 31: ...l ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a charge even if you...

Page 32: ...ure that the chassis cover is in place when the 6025W UR is operating to assure proper cooling Out of warranty damage to the system can occur if this practice is not strictly followed Figure 4 1 Insta...

Page 33: ...t the size and weight of the serverboard can cause it to bend if handled improperly which may result in damage To prevent the serverboard from bending keep one hand under the center of the board to su...

Page 34: ...2 When purchasing a Xeon CPU or when receiving a serverboard with a CPU pre installed make sure that the CPU plastic cap is in place and none of the CPU pins are bent otherwise contact the retailer i...

Page 35: ...wn into the socket Do not drop the CPU on the socket do not move the CPU horizontally or vertically and do not rub the CPU against any sur face or any of the contacts which may damage the CPU and or i...

Page 36: ...re installed heatsink reten tion mechanism Screw in two diagonal screws i e the 1 and the 2 screws until just snug Do not fully tighten the screws or you may damage the CPU 1 2 3 Removing the Heatsink...

Page 37: ...hould be connected See the serverboard layout diagram in this chapter for connector locations DVD ROM Drive cable IDE 1 Control Panel cable JF1 see next page SAS cables CBL 0188L one side connects to...

Page 38: ...tus LEDs in the chassis See the Connector De nitions section in this chapter for details and pin descrip tions of JF1 NMI x key Vcc Vcc Vcc Vcc Vcc Vcc Reset Power Ground x key Power LED HDD LED NIC1...

Page 39: ...ss down on the DIMM module until it snaps into place in the slot Repeat for all modules see step 1 above Memory Support The X7DWU supports up to 64 GB of ECC FBD Fully Buffered DIMM DDR2 800 667 533 S...

Page 40: ...em BIOS 1 MB 3 99 Local APIC 4 KB 3 99 Area Reserved for the chipset 2 MB 3 99 I O APIC 4 Kbytes 4 KB 3 99 PCI Enumeration Area 1 256 MB 3 76 PCI Express 256 MB 256 MB 3 51 PCI Enumeration Area 2 if n...

Page 41: ...nstalled to the system An additional two riser cards are included to support PCI E add on cards See con guration list below PCI Card Installation Before installing a PCI add on card make sure you inst...

Page 42: ...xpress x8 PCI Express x8 SXB1 PCI E x16 DIMM 4B JPW3 JPW1 North Bridge 5400 DIMM 4A DIMM 3B DIMM 3A DIMM 2B DIMM 2A DIMM 1B DIMM 1A SATA0 SATA1 SATA2 SATA3 SATA4 SATA5 IDE 1 BIOS Floppy ATI ES1000 COM...

Page 43: ...rive Connector IDE 1 IDE HDD Connector JD1 Speaker Header JF1 Front Panel Connector JK1 Chassis Intrusion Header JOH1 Overheat Warning Header JPW1 20 pin Main ATX Power Connector JPW2 4 pin Auxilliary...

Page 44: ...r connector above the Auxiliary 4 pin connector at JPW2 must also be con nected to your power supply See the table on the right for pin de nitions NMI Button Pin De nitions JF1 Pin De nition 19 Contro...

Page 45: ...on pins 13 and 14 of JF1 Attach the IDE hard drive LED cable to display disk activity Refer to the table on the right for pin de nitions HDD LED Pin De nitions JF1 Pin De nition 13 Vcc 14 HD Active Un...

Page 46: ...ton for at least 4 seconds Refer to the table on the right for pin de nitions Universal Serial Bus USB0 1 Two Universal Serial Bus ports are located on the I O backplane USB0 is the bottom connector a...

Page 47: ...e Pin 10 is included on the header but not on the port NC indicates no connection Serial Port Pin De nitions COM1 COM2 Pin De nition Pin De nition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Grou...

Page 48: ...rts Pin De nitions Pin De nition 1 Data 2 NC 3 Ground 4 VCC 5 Clock 6 NC Speaker Connector Pin De nitions JD1 Pin Function De nition 4 Speaker data red wire 5 Key No connection 6 Key 7 Speaker data Ov...

Page 49: ...e here to utilize SMB on your system See the table on the right for pin de nitions Wake On Ring Pin De nitions JWOR Pin De nition 1 Ground Black 2 Wake up SMBUS_PS This header is for I2 C which may be...

Page 50: ...controller and the SATA drive backplane to provide SATA enclosure management functions Connect the appropriate cables from the backplane to the SGPIO1 and SGPIO2 headers to utilize SATA management fu...

Page 51: ...clear CMOS and will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS First power down the system and u...

Page 52: ...Watch Dog Timer LAN Enable Disable Jumper Settings JPL1 Jumper Setting De nition Pins 1 2 Enabled Pins 2 3 Disabled Watch Dog Jumper Settings JWD Jumper Setting De nition Pins 1 2 Reset Pins 2 3 NMI...

Page 53: ...ated with the connection speed LED LAN LED Connection Speed Indicator LED Color De nition Off 10 MHz Green 100 MHz Amber 1 GHz LE1 The LE1 LED located near JD1 is the power LED LE1 illuminates when th...

Page 54: ...A and the connector that does not have twisted wires always connects to drive B Floppy Connector The oppy connector is designated Floppy See the table below for pin de nitions Floppy Drive Connector...

Page 55: ...0 Host Data 11 11 Host Data 3 12 Host Data 12 13 Host Data 2 14 Host Data 13 15 Host Data 1 16 Host Data 14 17 Host Data 0 18 Host Data 15 19 Ground 20 Key 21 DRQ3 22 Ground 23 I O Write 24 Ground 25...

Page 56: ...omputer icon and then on the icon representing your CD ROM drive Finally double click on the S Setup icon Click the icons showing a hand writing on paper to view the readme les for each item Click the...

Page 57: ...very carefully The following measures are generally suf cient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded me...

Page 58: ...Connect the cable from JF1 on the serverboard to the Control Panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out of the air ow path...

Page 59: ...an continue to run with a failed fan Remove the top chassis cover while the system is still running to determine which of the fans has failed Replacing System Fans Remove the chassis cover Press the t...

Page 60: ...need to access the inside of the chassis or remove power to replace or swap SAS SATA drives Proceed to the next step for instruc tions Note You must use standard 1 high SAS SATA drives in the SuperSer...

Page 61: ...holes align with those in the carrier Secure the drive to the carrier with four screws as shown in Figure 6 3 Installing Removing Hot swap SAS SATA drives Push the release button located beside the dr...

Page 62: ...operating system you use must have RAID support to enable the hot swap capability of the drives The backplane is already precon gured so there are no jumpers or switches present on it IDE and Floppy...

Page 63: ...included in the accessory box see Figure 6 5 To install an optional oppy drive remove the solid dummy bezel that covers either of the drive bays held to the tray with two side screws and replace with...

Page 64: ...oles provided Slide the drive into the bay and secure it to the chassis with the drive carrier screws you rst removed Attach the power and data cables to the drive Replace the top chassis cover before...

Page 65: ...the system However if you wish to temporarily remove it the air shroud should always be in place when the system is operating please follow this procedure Removing the Air Shroud Depress the tabs at...

Page 66: ...e power supply units have a hot swap capability meaning you can replace the failed unit without powering down the system Removing Replacing the Power Supply You do not need to shut down the system to...

Page 67: ...backup battery pro vides power to the CMOS Logic enabling it to retain system parameters Each time the computer is powered on the computer is con gured with the values stored in the CMOS Logic by the...

Page 68: ...ressing Delete immediately after turning the system on or When the message shown below appears brie y at the bottom of the screen during the POST Power On Self Test press the Delete key to activate th...

Page 69: ...ate Using the arrow keys highlight the month day and year elds and enter the correct data Press the Enter key to save the data BIOS Date This eld displays the date when this version of BIOS was built...

Page 70: ...yed in the submenu Type Selects the type of IDE hard drive The option Auto will allow the BIOS to auto matically con gure the parameters of the HDD installed at the connection Enter a number between 1...

Page 71: ...n multi sector transfer The options are Disabled 4 Sectors 8 Sectors and 16 Sectors LBA Mode Control This item determines whether the Phoenix BIOS will access the IDE Channel 0 Master Device via the L...

Page 72: ...le for you to select either Intel or Adaptec Host RAID rmware If this item is set to Disabled the item SATA AHCI Enable will be available The options are Enabled and Disabled ICH RAID Code Base Availa...

Page 73: ...ST Power On Self Test routine by skipping certain tests after the computer is turned on The settings are Enabled and Disabled If Disabled the POST routine will run at normal speed QuietBoot Mode This...

Page 74: ...n This feature allows the user to determine how to use the keyboard to power on the system from S3 S5 States Select Space to allow the user to power on the system by pressing the space bar Select Pass...

Page 75: ...and written into the system memory at the same time Select Write Protect to prevent data from being written into the base memory area of Block 0 512K Select Write Back to allow CPU to write data back...

Page 76: ...he options are Enabled and Disabled PCI Con guration Access the submenu to make changes to the following settings for PCI devices Onboard GLAN1 Onboard GLAN2 Gigabit LAN OPROM Con gure Enabling this o...

Page 77: ...rent Bus Master clock rate Large Disk Access Mode This setting determines how large hard drives are to be accessed The options are DOS or Other for Unix Novelle NetWare and other operating systems Adv...

Page 78: ...nly support 1 5V 4GB PCI Hole Granularity This feature allows you to select the granularity of PCI hole for PCI slots If MTRRs are not enough this option may be used to reduce MTRR occupation The opti...

Page 79: ...Sensor Select Enabled to activate the thermal sensor embedded in the Advanced Memory Buffer on a fully buffered memory module for thermal monitoring The options are Disabled and Enabled Thermal Thrott...

Page 80: ...Options Access the submenu to make changes to the following settings CPU Speed This is a display that indicates the speed of the installed processor Frequency Ratio Available when supported by the CPU...

Page 81: ...mation regarding hardware software support for this function please refer to Intel s and Microsoft s web sites Adjacent Cache Line Prefetch Available when supported by the CPU The CPU fetches the cach...

Page 82: ...y in an effort to reduce power consumption and heat dissipation The options are Enabled and Disabled Please refer to Intel s web site for detailed information C State Supported Available if supported...

Page 83: ...e Primary and Secondary DMI Event Logging Access the submenu to make changes to the following settings Event Log Validity This is a display to inform you of the event log validity It is not a setting...

Page 84: ...VT UTF8 and ASCII Flow Control This item allows you to select the ow control option for console redirection The options are None XON XOFF and CTS RTS Console Connection This item allows you to decide...

Page 85: ...Modulation PWM Select 3 pin if your chassis came with 3 pin fan headers Select 4 pin if your chas sis came with 4 pin fan headers Select Workstation if your system is used as a Workstation Select Serv...

Page 86: ...ystem Firmware Progress Enable this function to log POST progress The options are Enabled and Dis abled BIOS POST Errors Enabling this function to log POST errors The options are Enabled and Dis abled...

Page 87: ...ons display the System Event SEL Log and System Event SEL Log in List Mode Items included are shown in the screen shot below Realtime Sensor Data This feature display information from motherboard sens...

Page 88: ...ates if a supervisor password has been entered to the system Clear means such a password has not been used and Set means a supervisor password has been entered User Password Is This feature indicates...

Page 89: ...allow the BIOS to automatically download the drivers needed to provide support for the platforms speci ed The options are Enabled and Disabled If set to Enabled the TPM State screen displays Current...

Page 90: ...unctions for the devices included in the candidate list above are currently disabled Use a key or a key to move the device up or down Use the f key or the r key to specify the type of an USB device ei...

Page 91: ...iscarding Changes Highlight this item and hit Enter to exit the BIOS Setup utility without saving any changes you may have made Load Setup Defaults Highlight this item and hit Enter to load the defaul...

Page 92: ...7 26 SUPERSERVER 6025W UR User s Manual Notes...

Page 93: ...Keyboard controller failed test May require replacing keyboard controller Keyboard locked Unlock key switch Unlock the system to proceed Monitor type does not match CMOS Run SETUP Monitor type not co...

Page 94: ...evious POST did not complete successfully POST loads default values and offers to run Setup If the failure was caused by incorrect values and they are not corrected the next boot will likely fail On s...

Page 95: ...Software NMI Failed ServerBIOS2 test error Cannot generate software NMI Non Maskable Interrupt Fail Safe Timer NMI Failed ServerBIOS2 test error Fail Safe Timer takes too long device Address Con ict A...

Page 96: ...kilobytes successfully tested One or more I2O Block Storage Devices were excluded from the Setup Boot Menu There was not enough room in the IPL table to display all installed I2O block storage devices...

Page 97: ...p Optional message displayed during POST Can be turned off in Setup PS 2 Mouse PS 2 mouse identi ed Run the I2O Con guration Utility One or more unclaimed block storage devices have the Con guration R...

Page 98: ...A 6 SUPERSERVER 6025W UR User s Manual Not es...

Page 99: ...error in the top left corner of the screen The following is a list of codes that may be written to port 80h Appendix B BIOS POST Codes POST Code Description 01h IPMI Initialization 02h Verify Real Mod...

Page 100: ...n 38h Shadow system BIOS ROM 3Ah Auto size cache 3Ch Advanced con guration of chipset registers 3Dh Load alternate registers with CMOS values 41h Initialize extended memory for RomPilot optional 42h I...

Page 101: ...and IRQs optional 81h Late POST device initialization 82h Detect and install external RS232 ports 83h Con gure non MCD IDE controllers 84h Detect and install external parallel ports 85h Initialize PC...

Page 102: ...one prepare to boot operating system B4h 1 One short beep before boot B5h Terminate QuietBoot optional B6h Check password optional B7h Initialize ACPI BIOS and PPM Structures B9h Prepare Boot BAh Init...

Page 103: ...ory type EDh Initialize Memory size EEh Shadow Boot Block EFh System memory test F0h Initialize interrupt vectors F1h Initialize Run Time Clock F2h Initialize video F3h Initialize System Management Ma...

Page 104: ...B 6 SUPERSERVER 6025W UR User s Manual Notes...

Page 105: ...64 GB of ECC FBD Fully Buffered DIMM DDR2 800 667 533 SDRAM See the memory section in Chapter 5 for details SATA Controller Intel ESB2 on chip controller for six port Serial ATA RAID 0 1 5 and 10 sup...

Page 106: ...Frequency 50 to 60 Hz Power Supply Rated Output Power 700W Part PWS 702A 1R Rated Output Voltages 12V 57A 5V 30A 3 3V 24A 12V 0 6A 5Vsb 4A Operating Environment Operating Temperature 10 to 35 C 50 to...

Page 107: ...C 3 Appendix C System Speci cations Safety EN 60950 IEC 60950 Compliant UL Listed USA CUL Listed Canada TUV Certi ed Germany CE Marking Europe...

Page 108: ...C 4 SUPERSERVER 6025W UR User s Manual Notes...

Reviews: