
Chapter 2: Server Installation
2-5
Figure 2-3. Installing the Server into a Rack
Installing the Server into the Rack:
You should now have rails attached to both the chassis and the rack
unit. The next step is to install the server into the rack. Do this by
lining up the rear of the chassis rails with the front of the rack rails.
Slide the chassis rails into the rack rails, keeping the pressure even on
both sides (you may have to depress the locking tabs when inserting).
See Figure 2-3.
When the server has been pushed completely into the rack, you should
hear the locking tabs "click". Finish by inserting and tightening the
thumbscrews that hold the front of the server to the rack.
bly to the other side of the rack, making sure both are at the exact same
height and with the rail guides facing inward.
Summary of Contents for SUPERSERVER 6022P-i
Page 1: ...SUPERSERVER 6022P i USER SMANUAL 1 0a SUPER...
Page 5: ...v Preface Notes...
Page 10: ...SUPERSERVER 6022P i User s Manual x Notes...
Page 16: ...SUPERSERVER 6022P i Manual 1 6 Notes...
Page 26: ...2 10 SUPERSERVER 6022P i Manual Notes...
Page 30: ...SUPERSERVER 6022P i User s Manual 3 4 Notes...
Page 38: ...5 4 SUPERSERVER 6022P i User s Manual Figure 5 2 Heatsink Installation...
Page 58: ...5 24 SUPERSERVER 6022P i User s Manual Notes...
Page 64: ...6 6 SUPERSERVER 6022P i Manual Figure 6 3 Mounting a Drive in a Carrier...
Page 94: ...A 6 SUPERSERVER 6022P i Manual Notes...