Chapter 2: Server Installation
19
Note:
Figure is for illustrative purposes only. Always install servers to the bottom of a rack first.
Figure 2-2. Installing the Server into a Telco Rack
Installing the Server into a Telco Rack
The SuperServer 5019S-TN4 supports Telco Rack installation. The compact design of the
SC504 chassis allows it to be installed into a Telco rack without the use of rails.
1. To install the chassis into a Telco style two-post rack, use two L-shaped brackets on
either side of the chassis (four total).
2. First, determine how far follow the server will extend out the front of the rack. Larger
chassis should be positioned to balance the weight between front and back.
3. If a bezel is included on your chassis, remove it. Then attach the two front brackets to
each side of the chassis, then the two rear brackets positioned with just enough space
to accommodate the width of the Telco rack.
4. Finish by sliding the chassis into the rack and tightening the brackets to the rack.