134
SuperServer 2029BT-Hxxx User's Manual
System Cooling
Four 8-cm PWM fans; 16 air shrouds, eight CPU heatsinks
Power Supply
Model: PWS-2K22A-1R
AC Input Voltages: 100-240 VAC
Rated Input Current:
1800W: 200-220Vac
1980W: 220-230Vac
2090W: 230-240Vac
2090W: 180-220Vac (for UL/cUL only)
2200W: 220-240Vac (for UL/cUL only)
2090W: 230-240Vdc (for CCC only)
>
Rated Input Frequency: 50-60 Hz
Rated Output Power: +12 V
Max: 100A / Min: 0A (100-127Vac)
Max: 150A / Min: 0A (200-220Vac)
Max: 165A / Min: 0A (220-230Vac)
Max: 174.17A / Min: 0A (230-240Vac)
Max: 174.17A / Min: 0A (180-220Vac, UL/cUL only)
Max: 183.33A / Min: 0A (220-240Vac, UL/cUL only)
Max: 174.17A / Min: 0A (230-240Vdc, CCC only)
S12Vsb: Max: 2.1A / Min: 0A
Operating Environment
Operating Temperature: 10º to 35º C (50º to 95º F)
Non-operating Temperature: -40º to 60º C (-40º to 140º F)
Operating Relative Humidity: 8% to 90% (non-condensing)
Non-operating Relative Humidity: 5% to 95% (non-condensing)
Regulatory Compliance
Electromagnetic Emissions: FCC Class A, EN 55032 Class A, EN 61000-3-2/3-3, CISPR 32 Class A
Electromagnetic Immunity: EN 55024/CISPR 24, (EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6,
EN 61000-4-8, EN 61000-4-11)
Other: VCCI-CISPR 32 and AS/NZS CISPR 32
Environmental: Directive 2011/65/EU and Delegated Directive (EU) 2015/863 and Directive 2012/19/EU
Safety: CSA/EN/IEC/UL 60950-1 Compliant, UL or CSA Listed (USA and Canada), CE Marking (Europe)
Perchlorate Warning
California Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only to products
containing CR (Manganese Dioxide) Lithium coin cells. “Perchlorate Material-special handling may apply. See