3-14
AOC-SIMLP-B(+)/AOC-SIMLP-3(+) User's Guide
Health Monitoring Sensor Information on the Remote Host
Temperature Monitoring
CPU1 Temperature
(Temp A, Temp B)
Temp A: CPU1 Core1 Temperature, Temp B: CPU1
Core2 Temperature,
CPU2 Temperature
(Temp A, Temp B)
Temp A: CPU2 Core1 Temperature, Temp B: CPU2
Core2 Temperature,
System Temperature
Voltage Monitoring
CPU1 VCore
CPU1 Vcore: CPU1 Core Voltage
CPU2 VCore
CPU2 Vcore: CPU2 Core Voltage
3.3V
5V, 5VSB
5VSB: 5V Standby
+12V, -12V
1.5V
VBAT
VBAT: Battery Voltage
Fan Control
Fan1/CPU Fan
Fan2/CPU Fan
Fan 3 – Fan 6
System Fans/Chassis Fans
Physical Security
Chassis Intrusion
Module/Board CPU0
Internal E.
Module/Board CPU1
Internal E.
Module/Board CPU
Overheat
When the CPU temperature exceeds this preset
temperature, the overheat LED or alert will be
triggered, the CPUs will slow down, the CPU fans
will be in the full speed mode.
Module/Board Thermal
Trip
When the system temperature exceeds this preset
temperature, the overheat LED or alert will be
triggered, and the cooling fans will be in the full
speed mode to prevent system overheat.