Chapter 3: System Interface
3-3
Figure 5-1. Expander Status and Link LEDs
1
4
1
7
1
3
1
1
1
5
1
2
1
6
Item
Description
Status
1.
RJ45 Port
N/A
2.
Expander Status LED
Green: Initialization successful
Red: Initialization failed
3.
UID Status LED
On/ Off (controlled by the BMC)
4.
BMC Reset Button
N/A
5.
Cascade IN Ports
N/A
6.
Cascade OUT Ports
N/A
7.
Expander Link LEDs (2x IN, 2x OUT)
Green: All 4 PHY of each port connected with
consistent link speed (12G or 6G)
Red: Single PHY degraded link speed or
disconnected
3-4 Drive Carrier LEDs
Each drive carrier has two LEDs:
•
Green:
When illuminated, the green LED on the drive carrier indicates the drive
is powered on. If this LED is not lit, it means no power is being provided for the
drive. Please refer to Chapter 5 for instructions on replacing failed drives.
•
Red:
A steady red LED indicates a drive failure. The red LED is also used to
indicate drive location when a drive locate command is issued from the SAS
HDD controller
3-5 Expander Status and Link LEDs
Indicators for the expander status are located at the rear of the system. See the
figure below for descriptions.
Summary of Contents for SSG-937R-E2CJB
Page 1: ...Super Storage Bridge Bay SSG 937R E2CJB USER S MANUAL 1 0...
Page 5: ...Notes Preface v...
Page 8: ...Notes viii SSG 937R E2CJB User s Manual...
Page 22: ...3 4 SSG 937R E2CJB User s Manual Notes...
Page 42: ...4 20 SSG 937R E2CJB User s Manual Notes...