background image

Super Storage Bridge Bay

SSG-937R-E2CJB

USER’S MANUAL

 

 

1.0

Summary of Contents for SSG-937R-E2CJB

Page 1: ...Super Storage Bridge Bay SSG 937R E2CJB USER S MANUAL 1 0...

Page 2: ...any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits...

Page 3: ...cluded with the server system and describes the main features of the AOM SAS3 937EL JB serverboard and the SC937ETS chassis Chapter 2 Server Installation This chapter describes the steps necessary to...

Page 4: ...mation on the SC937 chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SAS or peripheral drives and when replacing system power supply units and c...

Page 5: ...Notes Preface v...

Page 6: ...1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 1 2 4 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature...

Page 7: ...10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cable and AC Adapter 4 18 Chapter 5...

Page 8: ...Notes viii SSG 937R E2CJB User s Manual...

Page 9: ...SAS midplane BPN SAS3 937 Sixteen hard drive carriers MCP 220 93703 0B One set of rackmount hardware MCP 290 00057 0N Note For your system to work properly please follow the links below to download a...

Page 10: ...68 1 99 Depressing the reset button again and holding it for 12 seconds will set it along with any other BMC settings back to the factory default 1 3 Server Chassis Features System Power The system fe...

Page 11: ...ion as a fully redundant fault tolerant cluster in a box system SBB JBOD is intended to expand SBB storage capacity while maintaining fault tolerant features by having the expanders located in hot swa...

Page 12: ...rope Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermic...

Page 13: ...placed near a grounded power outlet Read the Rack and Server Precau tions in the next section 2 3 Preparing for Setup The box the SSG 937R E2CJB was shipped in should include a rail kit to install the...

Page 14: ...or more si multaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the rack...

Page 15: ...sible overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable...

Page 16: ...Extend the inner rail toward the front of the rail assembly as far as possible then depress the locking tab to pull it completely out 2 Place the inner rail on the side of the chassis aligning the hoo...

Page 17: ...k and hold the server in place The outer rails for the SC937 chassis extend between 30 inches and 33 inches Installing the Outer Rails 1 Attach the right outer rail to the rack by inserting the hooks...

Page 18: ...ack rails 3 Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting When the server has been pushed completely into...

Page 19: ...er power both nodes on or off Turning off system power with this button removes the main power but keeps standby power supplied to the system 3 3 Control Panel LEDs The two control panels located on t...

Page 20: ...rify that the heatsinks are installed properly see Chapter 5 This LED will remain flashing or on as long as the indicated condition exists Cascading Status IN When this LED is illuminated it indicates...

Page 21: ...d Single PHY degraded link speed or disconnected 3 4 Drive Carrier LEDs Each drive carrier has two LEDs Green When illuminated the green LED on the drive carrier indicates the drive is powered on If t...

Page 22: ...3 4 SSG 937R E2CJB User s Manual Notes...

Page 23: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Page 24: ...idere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el te...

Page 25: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Page 26: ...des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher le...

Page 27: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Page 28: ...um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the ch...

Page 29: ...nentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enle...

Page 30: ...g Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utili...

Page 31: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Page 32: ...r equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beper...

Page 33: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Page 34: ...fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer t...

Page 35: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Page 36: ...ical codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Backplan...

Page 37: ...re install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften Warnung Di...

Page 38: ...moving parts Keep away from moving fan blades The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in t...

Page 39: ...s destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soien...

Page 40: ...er kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen...

Page 41: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Page 42: ...4 20 SSG 937R E2CJB User s Manual Notes...

Page 43: ...o prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions...

Page 44: ...h the node located on the same side of the chassis Note that only the right side control panel includes a power button Depressing this button will turn both nodes on or off See Chapter 3 for details o...

Page 45: ...inspected for failure Replace any failed fan at your earliest convenience with the same type and model the system can continue to run with a failed fan Check the IPMI sensor list to determine which o...

Page 46: ...5 4 SSG 937R E2CJB User s Manual Figure 5 2 Removing a Node Figure 5 3 Exploded View of Fan Assemblies 2 3...

Page 47: ...removal from the chassis The carriers also help promote proper airflow for the drives For this reason even empty carriers without hard drives installed must remain in the chassis Removing an HDD Carr...

Page 48: ...ept for short periods of time while swapping hard drives do not operate the server without all hard drive carriers inserted Caution Enterprise level hard disk drives are recommended for use in Supermi...

Page 49: ...Chapter 5 Advanced Chassis Setup 5 7 Figure 5 5 Removing the Dummy Drive from the Carrier Drive Carrier Dummy Drive 1 1 1 1 1 2 Figure 5 6 Installing a Drive to a Carrier 1 4 1 4 1 3...

Page 50: ...R479 R481 R478 R713 R489 R488 R487 R486 R467 R464 R466 R465 R712 R571 R572 R570 R569 R392 R391 R393 R390 R708 R397 R396 R395 R394 R400 R399 R401 R398 R707 R413 R412 R411 R410 R389 R386 R388 R387 R706...

Page 51: ...been replaced Replacement units can be ordered directly from Supermicro The power supply units have a hot swap capability meaning you can replace the failed unit without powering down the system Repla...

Page 52: ...5 10 SSG 937R E2CJB User s Manual Notes...

Page 53: ...fans behind the HDD backplane and at the rear of each node System Input Requirements AC Input Voltage 100 240 VAC Rated Input Current 12 9A 100 127V 7 2 6A 200 240V Rated Input Frequency 50 to 60 Hz P...

Page 54: ...hazardouswaste perchlorate continued from front The products sold by Supermicro are not intended for and will not be used in life support systems medical equipment nuclear facilities or systems aircr...