background image

5-11

Chapter 5: Chassis Setup and Maintenance

Changing the Power Supply:

1.  Unplug the AC cord from the module to be replaced.  

2.  Push the release tab on the back of the power supply as illustrated.

Figure 5-11. Power Supply Release Tab

Release Tab

3.  Pull the power supply out using the handle provided.

4.  Replace the failed power module with the same model.

5.  Push the new power supply module into the power bay until it clicks. 

6.  Plug the AC power cord back into the module.

Summary of Contents for SSG-927R-E2CJB

Page 1: ...USER S MANUAL Revision 1 0 Super Storage Bridge Bay SSG 927R E2CJB ...

Page 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commerci...

Page 3: ...vailable when this document was published Refer to the Supermicor web site for updates on supported parts and configurations This manual may be periodically updated without notice Please check the Supermicro Web site for possible updates Warnings Special attention should be given to the following symbols used in this manual Warning Indicates high voltage may be encountered when performing a proced...

Page 4: ...Setup 2 1 Choosing a Setup Location 2 1 2 3 Warnings and Precautions 2 2 Rack Precautions 2 2 General Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Sufficient Airflow 2 3 Circuit Overloading 2 3 Reliable Ground 2 3 2 4 Installing the Rails 2 4 Identifying the Rails 2 4 Releasing the Inner Rail 2 5 Installing the Inner Rails on the Chassis 2 6 Installing ...

Page 5: ... 4 5 Power Disconnection Warning 4 6 Equipment Installation 4 8 Restricted Area 4 9 Battery Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cable and AC Adapter 4 18 Chapter 5 Chassis Setup and Maintenance 5 1 Overview 5 1 5 2 Removing Power from the System 5 2 5 3 Removing...

Page 6: ...pe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Web Site www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Te...

Page 7: ...ious hardware components are included as listed below Eight 4 cm fans FAN 0157L4 SAS Accessories One SAS midplane BPN SAS3 927 N4 Twenty four drive carriers MCP 220 92701 0N Dual Power Supply 1200 W PWS 1K23A 1R One set of rackmount hardware MCP 290 00057 0N Note For your system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for you...

Page 8: ...r tray rear for 6 seconds will change it to a static IP address of 192 168 1 99 Depressing the reset button again and holding it for 12 seconds will set it along with any other local BMC settings back to the factory default 1 3 Chassis Features System Power The system features a redundant Titanium Level 1200W power supply composed of two separate power modules This power redundancy feature allows ...

Page 9: ...der within the same node through SES 1 4 Storage Bridge Bay SBB The Super SBB product line is designed to function as a fully redundant fault tolerant cluster in a box system SBB JBOD is intended to expand SBB storage capacity while maintaining fault tolerant features by having the expanders located in hot swappable trays Super SBB supports cascading for up to four Super SBB JBODs of the following...

Page 10: ...1 4 SUPERSERVER SSG 927R E2CJB User s Manual Notes ...

Page 11: ...nerated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail assemblies two rail mounting brackets and the mounting screws to mount the system into the rack Please read this chapter in its entirety before beginning the installation procedure Choosing a Setup Location Leave at least 25 inches clearance in front of the rack to open the front ...

Page 12: ...sly may cause the rack to become unstable General Server Precautions Review the electrical and general safety precautions that came with the components you are adding to your chassis Determine the placement of each component in the rack before you install the rails Install the heaviest server components on the bottom of the rack first and then work upward Use a regulating uninterruptible power sup...

Page 13: ...nsideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc Warning To prevent bodily injury when mounti...

Page 14: ...rectly to the chassis an outer rail that secures to the rack and a middle rail which extends from the outer rail These assemblies are specifically designed for the left and right side of the chassis and labeled Figure 2 1 Identifying the Outer Rail Middle Rail and Inner Rail Left Rail Assembly Shown Inner Rail Rail Assembly Shown with Rails Retracted This Side Faces Outward Locking Tab Middle Rail...

Page 15: ...er from coming completely out of the rack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails 1 Pull the inner rail out of the outer rail until it is fully extended as illustrated below 2 Press the locking tab down to release the inner rail 3 Pull the inner rail all the way out 1 1 1 2 1 3 ...

Page 16: ...y are labeled 2 Place the inner rail firmly against the side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis and under the hooks until the quick release bracket snaps into place securing the rail to the chassis 4 If desired add screws flat head M4 x 4mm through the rail into the chassis for...

Page 17: ...er Rack Rails Outer rails attach to the server rack and hold the server in place The outer rails extend between 30 inches and 33 inches Installing the Outer Rails 1 Attach the outer rails to the rack by inserting the hooks on the rails into the holes on the rack post 2 If desired screw the rails to the chassis for added support ...

Page 18: ...he front of the middle rail 2 Align the rear of the chassis rails with the middle rails and then push evenly on both sides of the chassis until it clicks into the fully extended position 3 Depress the locking tabs on both sides of the chassis and push the it fully into the rack The locking tabs should click 4 Optional screws may be used to hold the front of the chassis to the rack Note The figure ...

Page 19: ...eavy chassis from the rack without assistance Be sure to have sufficient assistance supporting the chassis when removing it from the rack Use a lift Removing the Chassis from the Rack 1 Pull the chassis forward out the front of the rack until it stops 2 Press the release latches on each of the inner rails downward simultaneously and move the chassis forward in the rack 1 2 ...

Page 20: ...SSB 927R E2C JB User s Manual 2 10 Notes ...

Page 21: ...ch control panel provides LED status indicators related to the node on the same side of the chassis The control panel on the right includes a power button for the entire system The externally accessible hard drives display status lights The power supply displays status lights visible from the back of the chassis Figure 3 1 Front Control Panel ...

Page 22: ...dby power 3 2 Control Panel Buttons The control panel on the right includes a power button for the system Power Indicates power is being supplied to the system power supply units This LED is illuminated when the system is operating normally 1 Cascading Status IN When this LED is illuminated it indicates a cable for cascading from the head node has been attached to the system Heartbeat The heartbea...

Page 23: ...it indicates a cable for cascading to a second level JBOD has been attached to the system Overheating Multiple sensors within system will post overheat alerts check IPMI for current temperature readings and threshold and critical values There are several possible responses if the system overheats If the server overheats 1 Use the LEDs to determine the nature of the overheating condition 2 Confirm ...

Page 24: ...uccessful Red Initialization failed 3 UID LED On Off controlled by the BMC 4 BMC Reset Button n a 5 Cascade IN Ports n a 6 Cascade OUT Ports n a 7 Expander Link LEDs 2x IN 2x OUT Green All PHY 12 G speed Green All PHY 6 G speed Red Other status 3 4 Expander Status and Link LEDs Indicators for the expander status are located at the rear of each node See the figure below for descriptions ...

Page 25: ...er to Chapter 5 for instructions on replacing failed drives The red LED is also used to indicate drive location when a drive locate command is issued from the SAS HDD controller 3 6 Power Supply LEDs On the rear of the power supply module an LED displays the status Solid Green When illuminated indicates that the power supply is on Solid Amber When illuminated indicates the power supply is plugged ...

Page 26: ...SSB 927R E2C JB User s Manual 3 6 Notes ...

Page 27: ...onfiguring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for prevent...

Page 28: ...úmero que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux circui...

Page 29: ...ordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES ً ف اًك أى ٌوكي حالة ً ف تتسبب اصابة جسذٌة الزهز هذا ًٌ ...

Page 30: ...stalación antes de conectar el sistema a la red de alimentación Attention Avant de brancher le système sur la source d alimentation consulter les directives d installation 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい ال إرشادات اقر تركيب توصيل قبل إلى النظام للطاقة مصدر לקרוא יש למקור המערכת חיבור לפני התקנה הוראות את מתח 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies voorda...

Page 31: ...liza el sistema de protección contra cortocircuitos o sobrecorrientes del edificio Asegúrese de que el dispositivo de protección no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A על מסתמך זה ...

Page 32: ...den Spg Versorgungsteilmodulen entfernt wird bevor es Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 합니다 Waarschuwing Dit product is afhankelijk van de ...

Page 33: ...céder à l intérieur du chassis pour installer ou enlever des composants de systéme חשמלי ניתוק מפני אזהרה אזהרה החשמל מקורות מכל המערכת את לנתק יש להסיר ויש מהספק החשמלי כבל את התקנ לצורך המארז של הפנימי לחלק גישה לפני ת הסר או ת רכיבים فصم يجب اننظاو جميع من مصادر انطاقت وإزانت انكهرباء سهك من وحدة امداد انطاقت قبم إنى انىصىل انداخهيت انمناطق ن ههيكم إزانت أو نتثبيج مكىناث الجهاز 경고 시스템에 부품들을 장착하...

Page 34: ...tattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד والمدربيه و لتزكيب استبدال أو خدمة الجهاس هذا يسمح أن يجب ف...

Page 35: ... in Bereichen mit beschränktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich Advertencia Esta unidad ha sido diseñada para instalación en áreas de acceso restringido Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial cerradura con lla...

Page 36: ...م انىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap slot en s...

Page 37: ...ipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante אזהרה סכנת קיימת פיצוץ תקינה לא בדרך והוחלפה במידה הסוללה של להחליף יש בסוג הסוללה את מ התואם חברת מומל יצרן צת הסוללות סילוק המשומשות לבצע יש היצרן הוראות לפי خطر هناك من اسحبذال حالة في انفجار البطارية صحيحة غير بطريقة فعليل البطارية اسحبذال فقط النىع بنفس يعادلها ما أو مما أو...

Page 38: ...e unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées Redundant Power Supplies Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接続を取り外さなけれ...

Page 39: ...idado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing قد لهذا يكون ال جهاز اتصاالت عدة بوحدات الطاقة امداد إزالة يجب االتصاالت كافة لعسل ال وحدة عن الكهرباء...

Page 40: ...o debe cumplir con las normas de electricidad locales y nacionales هناك خطز مه الكهزبائي التيار على المىجىدة أوالطاقة اللىحة يكىن عندما النظام يعمل عند حذرا كه خدمة الجهاس هذا 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het onde...

Page 41: ...اويه والىطىية المحلية المتعلقة بالكهرباء Attention L équipement doit être installé conformément aux normes électriques nationales et locales 경고 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다 Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften 製品の廃棄 この製品を廃棄処分する場合 国の関係する全ての法律 条例に従い処理する必要が あります 警告 本产品的废弃处理应根据所有国家的法律和规章进行 警告 本產品的廢棄處理應根據所有國家的法律和規...

Page 42: ...ר סילוק אזהרה ו להנחיות בהתאם להיות חייב זה מוצר של סופי סילוק המדינה חוקי النهائي التخلص من المنتج هذا معه التعامل ينبغي ل وفقا جميع الىطنية واللىائح القىانين عند 경고 이 제품은 해당 국가의 관련 법규 및 규정에 따라 폐기되어야 합니다 ファン ホッ トスワップの警告 警告 回転部品に注意 運転中は回転部 羽根 に触れないでく ださい シャーシから冷 却ファン装置を取り外した際 ファンがまだ回転している可能性があり ます ファンの開 口部に 指 ドライバー およびその他のものを近づけないで下さい 警告 警告 危险的可移动性零件 请务必与转动的风扇叶片保持距离 当您从机架移除 风扇装置 风扇可能仍在转动 小心不要将手指 螺...

Page 43: ...s Mantener alejado de las aspas del ventilador Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient toujours en rotation lorsque vous ret...

Page 44: ...f der Code für alle anderen elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben Advertencia Al instalar el producto utilice los cables de conexión previstos o designados los cables y adaptadores de CA La utilización de otros cables y adaptadores podría ocasionar un mal funcionamiento o un incendio Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe el uso de UL ...

Page 45: ...צוין שלא تركيب عىذ استخذام يجب الجهاز و التىصيل كابالث الكهربائيت الكابالث ومحىالث المتردد التيار أن أي استخذام كابالث ومحىالث أخري يتسبب في عطل حذوث حريق أو التي لك تىفيرها تم المىتج مع UL أو CSA الكهربائيت األجهسة ومىاد قاوىن السالمت استخذام يحظر الكابالث قبل مه معتمذة Supermicro أجهسة أخري كهربائيت غير المىتجاث المعيىت قبل مه ألي UL CSA تحمل التي عالمت 경고 제품을 설치할 때에는 제공되거나 지정된 연결케이블과 전원케이블 AC어댑...

Page 46: ...4 20 SSB 927R E2C JB User s Manual Notes ...

Page 47: ...ool required is a Phillips screwdriver Review the warnings and precautions listed in the manual before setting up or servicing this chassis These include information in Chapter 4 Warning Statements for AC Systems and the warning precautions listed in the setup instructions Figure 5 2 Rear View Ports Reset Button and Indicators described in Chapter 3 Control Panel Hot Swap HDDs 24 Control Panel Fig...

Page 48: ...intenance tasks use the following procedure to ensure that power has been removed from the system 1 Press the power button on the right front control panel 2 Grasp the head of each power cord and pull it from the back of the power supply module 3 Disconnect the cords from the power strip or wall outlet ...

Page 49: ...from the mid chassis to access internal components Removing the Chassis Top Cover 1 Remove the two screws securing the cover to the top of the chassis 2 Lift it up and off Caution Except for short periods of time do not operate the server without the cover in place The chassis cover must be in place to allow proper airflow and prevent overheating ...

Page 50: ...ion Except for short periods of time while swapping hard drives do not operate the server without hard drives in the hard drive bays Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers Refer to a list at http www supermicro com Storage Drive Midplane The drives plug into a midplane that provides power to the drives and the controller nodes It also provides b...

Page 51: ...rriers from the Chassis 1 Press the release button on the drive carrier This extends the drive bay handle 2 Use the handle to pull the drive out of the chassis Figure 5 4 3 Remove the dummy drive from the carrier Figure 5 5 Figure 5 4 Removing a Hard Drive Carrier 1 2 ...

Page 52: ...e mounting holes in the drive align with those in the carrier 2 Secure the hard drive into the carrier with the screws Figure 5 5 Removing Dummy Drive from Carrier 3 Use the open handle to replace the drive carrier into the chassis 4 Gently close the drive carrier handle to secure the drive and carrier into the chassis drive bay Figure 5 6 Installing the Hard Drive ...

Page 53: ...de tray Mid Chassis Fans Replacing a System Fan 1 Use IPMI or another monitoring tool if available to determine which fan has failed 2 Open the chassis cover If a monitoring tool is not available observe which fan has failed Never run the server for an extended period of time with the chassis cover open 3 Remove the failed fan s power cord from the midplane Figure 5 7 Mid chassis Fans ...

Page 54: ...g while making sure the arrows on the top of the fan indicating airflow direction point in the same direction as the arrows on the other fans 6 Replace the pins and reconnect the fan wires to the backplane 7 Check that the fan is working properly before replacing the chassis cover Figure 5 8 Removing Pins from the Fan Housing en the top f the failed over open oard ng sure the e direction evious fa...

Page 55: ...5 9 Chapter 5 Chassis Setup and Maintenance Figure 5 9 Placing the Rear Fans on the Node Tray Rear Node Tray Fans ...

Page 56: ...be ordered directly from Supermicro or authorized distributors These power supplies are auto switching capable This feature enables them to automatically sense the input voltage and operate at a 100 120v or 180 240v An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Figure 5 10 Power Supply Modules ...

Page 57: ...e release tab on the back of the power supply as illustrated Figure 5 11 Power Supply Release Tab Release Tab 3 Pull the power supply out using the handle provided 4 Replace the failed power module with the same model 5 Push the new power supply module into the power bay until it clicks 6 Plug the AC power cord back into the module ...

Page 58: ...SSG 927R E2CJB User s Manual 5 12 Notes ...

Page 59: ...C927ETS 2U rackmount Dimensions WxHxD 17 5 x 3 5 x 25 5 in 44 5 x 89 x 64 8 mm Weight Barebones Net Weight 38 5 lbs 17 5 kg Gross weight 59 lbs 26 8 kg System Cooling Eight 4 cm high performance counter rotating fans System Input Requirements AC Input Voltage 100 240 V AC auto range Rated Input Current 12 9A 100 127V 7 2 6A 200 240V Rated Input Frequency 50 to 60 Hz Power Supply Rated Output Power...

Page 60: ...nge Regulatory Compliance Electromagnetic Emissions FCC Part 15B Class A EN 55032 Class A EN 61000 3 2 3 3 CISPR 32 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 VCCI V 3 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe VCCI Japan RCM Australia California Best Ma...

Page 61: ...A 3 Appendix A System Specifications Notes ...

Page 62: ...rm be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or sell such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims...

Reviews: