SC826 Chassis Manual
5-4
5-4 Rack Mounting Instructions
This section provides information on installing the SC826 chassis into a rack unit
with the rails provided. There are a variety of rack units on the market, which may
mean the assembly procedure will differ slightly. You should also refer to the instal-
lation instructions that came with the rack unit you are using.
NOTE:
This rail will fit a rack between 26" and 33.5" deep.
Identifying the Sections of the Rack Rails
The chassis package includes two rack rail assemblies in the rack mounting kit.
Each assembly consists of two sections: an inner fixed chassis rail that secures
directly to the server chassis and an outer fixed rack rail that secures directly to
the rack itself.
Figure 5-1. Identifying the Sections of the Rack Rails
Inner Rails
(Inner Rail is preinstalled
to the chassis)
Inner Rail Extensions
Locking Tabs
Both chassis rails have a locking tab. The tabs lock the server into place when
installed and pushed fully into the rack. These tabs also lock the server in place
when fully extended from the rack. This prevents the server from coming completely
out of the rack when you pull it out for servicing.
Rail Locking Tabs
Summary of Contents for SC826E1-R800LP
Page 35: ...4 17 Chapter 4 Chassis Setup and Maintenance Figure 4 14 Placing the System Fan ...
Page 46: ...SC826 Chassis Manual 5 8 Notes ...
Page 50: ...SC826 Chassis Manual A 4 Notes ...
Page 52: ...SC826 Chassis Manual B 2 Notes ...
Page 85: ...D 22 Appendix D SAS 826EL Backplane Specifications Notes ...