Summary of Contents for SBI-7147R-S4X

Page 1: ...SBI 7147R S4X Blade Module User s Manual Revison 1 0...

Page 2: ...resolution of any such disputes Supermicro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply wit...

Page 3: ...eral overview of safety precautions that should be followed when installing and servicing SBI 7147R S4X blade module Chapter 3 Setup and Installation Refer to this chapter for details on installing th...

Page 4: ...SBI 7147R S4X Blade Module User s Manual iv Notes...

Page 5: ...Power Disconnection Warning 2 5 Equipment Installation 2 6 Restricted Area 2 7 Battery Handling 2 9 Redundant Power Supplies 2 10 Backplane Voltage 2 11 Comply with Local and National Electrical Code...

Page 6: ...ware 3 14 3 9 Configuring and Setting up RAID 3 14 Chapter 4 Blade Module Features 4 1 4 1 Control Panel 4 2 Power Button 4 3 KVM Button 4 3 LED Indicators 4 3 KVM Connector 4 3 4 2 Mainboard 4 4 Jump...

Page 7: ...vii Table of Contents 5 9 Security 5 18 5 10 Save Exit 5 19 Appendix A AMI UEFI BIOS POST Codes A 1 A 1 Checkpoint Ranges A 1 A 2 Standard Checkpoints A 2 A 3 OEM Reserved Checkpoint Ranges A 9...

Page 8: ...SBI 7147R S4X Blade Module User s Manual viii Notes...

Page 9: ...se follow the links below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Product drivers and utili...

Page 10: ...16 240 pin DIMM sockets that can support up to 512 GB RDIMM 128 GB UDIMM or 1 TB LRDIMM DDR3 1866 1600 1333 1066 MHz speed 64GB 32GB 16GB 8GB 4GB 2GB and 1GB size SDRAM memory Memory is interleaved wh...

Page 11: ...e 3 1 for storage installation details RAID Each SBI 7147R S4X blade module supports up to four hard drives which may be used with SAS2 drives to create a RAID 0 1 and 10 system Further information on...

Page 12: ...ro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support...

Page 13: ...ed technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These warnings may also be fou...

Page 14: ...o considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar...

Page 15: ...m ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES Installation Instructions Warning Read the i...

Page 16: ...angewiesen dass im Geb ude ein Kurzschluss bzw berstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo util...

Page 17: ...Warning Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system c...

Page 18: ...les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enlever des composants de syst me Waarschuwing Voordat u toegang neemt...

Page 19: ...nd de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Waarschuwing Deze apparatuur mag alleen worden ge nstalleerd vervangen of hers...

Page 20: ...o a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...

Page 21: ...ichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplac e correctement Ne...

Page 22: ...onnection All connections must be removed to de energize the unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle Ver...

Page 23: ...ckplane when the system is operating Use caution when servicing Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung...

Page 24: ...Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes Warnung Die Installation der Ger te muss den Sicherheitsstand...

Page 25: ...according to all national laws and regulations Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este pro...

Page 26: ...drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten Sie Finger Schraubendreher und andere Gegenst nde von den ffnungen des L ftergeh uses entfernt Advertencia Los venti...

Page 27: ...wer Cable and AC Adapter Warning When installing the product use the provided or designated connection cables power cables and AC adaptors Using any other cables and adaptors could cause a malfunction...

Page 28: ...utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CSA cables certificados que...

Page 29: ...de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet...

Page 30: ...SBI 7147R S4X Blade Module User s Manual 2 18 Notes...

Page 31: ...off independently from the rest of the blades installed in the same enclosure A blade unit may be powered up in two ways Press the power button on the blade unit Use IPMIView or the web browser based...

Page 32: ...nclosure above 2 Depress the two buttons on the cover while pushing the cover toward the rear of the blade unit When it stops lift the cover off the blade unit 3 To replace the cover fit the six groov...

Page 33: ...3 3 Chapter 3 Setup and Installation Figure 3 1 Inserting a Blade into the Enclosure Figure 3 2 Locking the Blade into Position...

Page 34: ...g comes into contact with the thermal grease on its underside 5 Raise the lever of the processor socket up until the processor is released from the socket then lift the silver cover plate and remove t...

Page 35: ...Press the second load lever labeled Close 1st to release the load plate that covers the CPU socket from its locking position Figure 3 4 Figure 3 3 Open First Load Lever Figure 3 4 Close First Load Lev...

Page 36: ...n the load plate Lift the load plate to open it completely Figure 3 5 4 Using your thumb and the index finger remove the WARNING plastic cap from the socket Figure 3 6 Figure 3 5 Opening the Load Plat...

Page 37: ...y pins of the socket to avoid damaging the CPU or the socket Caution You can only install the CPU inside the socket in one direction Make sure that the CPU is properly inserted into the CPU socket bef...

Page 38: ...lever labeled Open 1st second Figure 3 11 Use your thumb to gently push the load levers down to the lever locks Figure 3 9 Closing the Load Plate Figure 3 10 Locking the Close First Lever Figure 3 11...

Page 39: ...per Micro authorized manufacturer due to compatibility issues See details below on supported memory and our web site www supermicro com products superblade for recommended memory Populating Memory Slo...

Page 40: ...ts of four 4 DIMMs for the CPU s Table 3 1 Populating Eight Memory Slots for Interleaved Operation of DIMMs CPU1 CPU2 CPU3 CPU4 Channel A Channel B Channel C Channel D Channel E Channel F Channel G Ch...

Page 41: ...odule to prevent inserting the DIMM incorrectly see Figure 3 14 5 Gently press down on the DIMM until it snaps into place in the slot Repeat for all modules see Table 3 1 for installing DIMMs into the...

Page 42: ...hard drive use the following procedure Installing a Hard Drive 1 Remove a blank drive carrier from the blade see removal procedure above 2 Insert a drive into the carrier with the PCB side facing dow...

Page 43: ...nnect a monitor to the video connector on the SUV cable Turn on the blade module 3 Insert the CD containing the OS into the CD ROM drive 4 Follow the prompts to begin the installation Installing via P...

Page 44: ...nsive set of functions and monitored data to keep tabs on the system and perform management activities Refer to the manuals on your SuperBlade CD ROM for further details on the various functions provi...

Page 45: ...et R LGA 2011 E5 4600 V2 series processors Memory Supports up to 512 GB of RDIMM and 128 GB of UDIMM DDR3 1866 1600 1333 1066 MHz speed 64GB 32GB 16GB 8GB 4GB 2GB and 1GB size SDRAM memory in sixteen...

Page 46: ...ns blade module on and off 2 KVM Button N A Initiates KVM function 3 Power LED Green Indicates power status On Orange Indicates power status Off with power cables plugged in 4 KVM UID LED Blue Indicat...

Page 47: ...other blade disconnect the cable then reconnect it to the new blade See the Web based Management Utility User s Manual on your SuperBlade system CD ROM for further details on using the KVM function re...

Page 48: ...t is a proprietary design which is based on the Intel C602J chipset See Figure 4 4 for a block diagram of this chipset Figure 4 3 for a view of the B9QR7 TP mainboard and Figure 4 5 for an exploded vi...

Page 49: ...ernet Chip 10 BMC Chip DDR3 DIMMH1 DDR3 DIMMG1 SATA PORT0 6G S CPU REAR CPU2 DDR3 DIMMF1 DDR3 DIMME1 QPI SYSTEM BIOS DDR3 DIMML1 DDR3 DIMMK1 CPU FRONT CPU3 DDR3 DIMMJ1 DDR3 DIMMI1 QPI GEN3 x8 nvSRAM F...

Page 50: ...d will also clear any passwords JBT1 consists of two contact pads located near the BIOS chip Clearing CMOS 1 First power down the blade and remove it from the enclosure 2 Remove the blade cover to acc...

Page 51: ...xploded View of a SBI 7147R S4X Blade Module Table 4 5 Main Components of a SBI 7147R S4X Blade Module Item Description 1 Blade Unit Module 2 2 5 SATA SAS2 SSD Hard Drives four 3 CPUs Heatsinks 2 4 DI...

Page 52: ...hot swapped and removed or replaced without powering down the blade unit they reside in The four drives can be used to set up a RAID array RAID 0 1 and 10 These drives use a blue color for the Blade...

Page 53: ...ittle electrical power When the blade unit is turned off a backup battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the blade is powered on it is configur...

Page 54: ...included with the system 1 Copy the contents of the zip file to a bootable USB pen drive 2 Connect the KVM dongle CBL 0218L to the KVM connector at the front of the blade you will be flashing the BIOS...

Page 55: ...ROM file name such as B8DTE142 rom for example in the command 5 3 Running Setup Note Default settings are in bold text unless otherwise noted The BIOS setup options described in this section are selec...

Page 56: ...LEFT RIGHT arrow keys to change the options for each setting Press the ESC key to exit the CMOS SETUP menu The next section describes in detail how to navigate through the menus Items that use sub men...

Page 57: ...correct data for the system date Press the Enter key to save the data System Time To set the system date and time key in the correct information in the appropriate fields Then press the Enter key to...

Page 58: ...s sub menu Super IO Configuration See Table 5 9 for a description of BIOS setup menu options in this sub menu Serial Port Console Redirection See Table 5 10 for a description of BIOS setup menu option...

Page 59: ...is Enabled for Windows XP and Linux OS optimized for Hyper threading technology and Disabled for other OSes any OS not optimized for Hyper threading techology When Disabled only one thread per enable...

Page 60: ...abled C1E Support Enabled CPU C3 Report Disabled CPU C6 Report Enabled CPU C7 Report Enabled Package C state Limit C6 Energy Performance Long Duration Power Limit Long Duration Maintained Short Durati...

Page 61: ...allows you to Enable or Disable Meseg in your system QPI Link Speed Mode This setting allows you to select QPI Link Speed as being either Fast or Slow mode QPI Link Frequency Select This setting allow...

Page 62: ...ller 1 2 Legacy USB Support This setting allows you to enable the use of Legacy USB devices If this option is set to Auto legacy USB support will be automatically enabled if a legacy USB device is ins...

Page 63: ...I device to generate a SERR Maximum Payload Use this setting to set the maximum payload of the PCI Express device or allow the system BIOS to select the value Options include Auto 128 Bytes 256 Bytes...

Page 64: ...l setting for the Super IO device to use for the Serial Port Options include Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 12 IO 2F8h IRQ 3 12 IO 3E8h IRQ 3 12 and IO 2E8h IRQ 3 12 Device Mode This setting allows...

Page 65: ...0x24 or 80x25 Putty KeyPad This setting allows you to select the funtion key and KeyPad to use on the Putty keyboard Options include VT100 LINUX XTERMR6 SCO ESCN or VT400 COM2 Console Redirection Use...

Page 66: ...ngs This sub menu contains Console Redirection settings for Out of Band Management Windows Emergency Management Services EMS Static display information for Data Bits Parity and Stop Bits is also shown...

Page 67: ...on Technology Configuration using the TXT Support setting TXT Support TXT requires a properly configured TPM LT SX enabled CPU and dependencies listed under this setting Options include Enabled or Dis...

Page 68: ...logging of system boot events MECI This setting Multiple Event Count Increment is used to select the number of occurrences of a duplicate event that must pass before the multiple event counter associa...

Page 69: ...choose options for reactions to a full SEL Options include Do Nothing and Erase Immediately Log EFI Status Codes Use this setting to Enable or Disable logging of EFI status codes log only error codes...

Page 70: ...e sequence of priority for the boot device such as hard disk drives USB devices CD ROM drives Network drives and so on The menu options are for 1st Boot Device 2nd Boot Device and 3rd Boot device Each...

Page 71: ...nd implement the changes you have made to the BIOS Setup Save Changes Highlight this item and hit ENTER to save changes done so far to any of the setup options Discard Changes Highlight this item and...

Page 72: ...SBI 7147R S4X Blade Module User s Manual 5 20 Notes...

Page 73: ...ndicate the task the system is currently executing Checkpoints are very useful in aiding software developers or technicians in debugging problems that occur during the pre boot process A 1 Checkpoint...

Page 74: ...fter microcode loading 0x0A OEM initialization after microcode loading 0x0B Cache initialization 0x0C 0x0D Reserved for future AMI SEC error codes 0x0E Microcode not found 0x0F Microcode not loaded Ta...

Page 75: ...itialization 0x35 CPU post memory initialization Boot Strap Processor BSP selection 0x36 CPU post memory initialization System Management Mode SMM initialization 0x37 Post Memory North Bridge initiali...

Page 76: ...0xE1 S3 Boot Script execution 0xE2 Video repost 0xE3 OS S3 wake vector call 0xE4 0xE7 Reserved for future AMI progress codes S3 Resume Error Codes 0xE8 S3 Resume Failed 0xE9 S3 Resume PPI not Found 0x...

Page 77: ...e Services 0x63 CPU DXE initialization is started 0x64 CPU DXE initialization CPU module specific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 C...

Page 78: ...0x79 CSM initialization 0x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PCI Bu...

Page 79: ...System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization c...

Page 80: ...be met Table A 7 ACPI ASL Checkpoints Status Codes Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is ente...

Page 81: ...anges Status Codes Description 0x05 OEM SEC initialization before microcode loading 0x0A OEM SEC initialization after microcode loading 0x1D 0x2A OEM pre memory initialization codes 0x3F 0x4E OEM PEI...

Page 82: ...SBI 7127R SH Blade Module User s Manual A 10 Notes...

Page 83: ...ected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such...

Page 84: ...SBI 7147R S4X Blade Module User s Manual 0 2 SBI 7147R S4X...