Chapter 5: BIOS
Hyper Transport Configuration
The menu options in the H
YPER
T
RANSPORT
C
ONFIGURATION
submenu and their
descriptions are shown in
.
Debug Option Configuration
The menu options in the D
EBUG
O
PTION
C
ONFIGURATION
submenu and their descriptions
are shown in
Table 5-14. Hyper Transport Configuration Submenu
Menu Option
Description
HT Extended Address
This setting allows you to Enable or Disable the HT extended address. Options
include Enabled,
Disabled
and Auto.
HT3 Link Power State
This setting allows you to configure the HT3 Link power state. Options include
Auto
, LS0, LS1, LS2 and LS3.
UnitID Clumping
Use this setting to configure Unit ID clumping. Options include
Disabled
, Auto,
UnitID 2/3, UnitID B/C and UnitID 2/3 & B/C.
HT Link Tristate
This setting allwos you to configure the HT Link Tristate. Options include
Auto
,
Disabled, CAD/CTL and CAD/CTL/CLK.
NB Deemphasies
Level
Use this to set the NB deemphasis level. Options include Disabled, 0.4 dB, 1.32
dB,
-2.08dB
, 3.1 dB, 4.22 dB, 5.50 dB and 7.05 dB.
X
Debug Opton
This sub-menu allows you to set Debug options for Hyper Transport
configuration.
NB
Transmitter
Attenuation
This setting allows you to set NB Transmitter Attenuation. Use the +/- keys on
your keyboard to set a number for this setting. Default is
00
.
CPU
Transmitter
Attenuation
This setting allows you to set CPU Transmitter Attenuation. Use the +/- keys on
your keyboard to set a number for this setting. Default is
00
.
CPU
Deemphasies
Level
Use this setting to set the deemphasies level for the CPU. Options include
Disabled
, 3db, 6db and 8db.
NB & CPU HT
Time
Margining
Use this setting to Enable or
Disable
NB & CPU HT Time Margining.
Table 5-15. Debug Option Configuration Submenu
Menu Option
Description
Memory Decode on
Sec. GFX
Use this setting to set memory decode on the second GFX. Options include
Disable
and Force.
IOC Peer-to-Peer
Mode
Use this setting to set the IOC Peer-to-Peer Mode. Options include
Auto
,
Default, Mode 1 and Mode 2.
Northridge Interrupt
Pin
Use this setting to Enable or
Disable
the NorthRidge Interrupt Pin.
Summary of Contents for SBA-7141A-T
Page 1: ...SBA 7141A T Blade Module User s Manual Revison 1 0 ...
Page 4: ...SBA 7141A T Blade Module User s Manual iv Notes ...
Page 8: ...SBA 7141A T Blade Module User s Manual 8 Notes ...
Page 10: ...SBA 7141A T Blade Module User s Manual 10 Notes ...
Page 12: ...SBA 7141A T Blade Module User s Manual 12 Notes ...
Page 30: ...SBA 7141A T Blade Module User s Manual 3 12 Notes ...
Page 38: ...SBA 7141A T Blade Module User s Manual 4 8 Notes ...
Page 70: ...SBA 7141A T Blade Module User s Manual A 10 Notes ...