Supermicro MicroBlade MBI-6218G-T41X User Manual Download Page 48

MBI-6218G-T41X MicroBlade Module User’s Manual

5-4

5-4

Main BIOS Setup

All Main Setup options are described in this section. Use the U

P

/D

OWN

 arrow keys to 

move among the different settings in each menu. Use the L

EFT

/R

IGHT

 arrow keys to 

change the options for each setting. Press the <E

SC

> key to exit the CMOS S

ETUP

 

menu. The next section describes in detail how to navigate through the menus. Items 
that use sub-menus are indicated with the 

 icon. With the item highlighted, press the 

<E

NTER

> key to access the submenu.

Menu options found in the M

AIN

 BIOS S

ETUP

 menu are described in 

Table 5-1

.

Figure 5-2. BIOS Setup Screen

Table 5-1. Main BIOS Setup Menu Options

Menu Option

Description

System Date

Using the arrow keys, highlight the month, day and year fields, and enter 
the correct data for the system date. Press the <Enter> key to save the 
data.

System Time

To set the system date and time, key in the correct information in the 
appropriate fields. Then press the <Enter> key to save the data.

BIOS Information

BIOS static display information including the serverboard number, SMC 
version, SMC Build Date and Memory Information is also shown on the 
screen.

Summary of Contents for MicroBlade MBI-6218G-T41X

Page 1: ...MBI 6218G T41X MicroBlade Module User s Manual Revison 1 0a...

Page 2: ...ve venue for the resolution of any such disputes Supermicro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and fo...

Page 3: ...and Installation Refer to this chapter for details on installing the MBI 6218G T41X MicroBlade module into the MicroBlade chassis Other sections cover the installation and placement of memory modules...

Page 4: ...MBI 6218G T41X MicroBlade Module User s Manual iv...

Page 5: ...quipment Installation 2 6 Restricted Area 2 7 Battery Handling 2 9 Redundant Power Supplies 2 10 Backplane Voltage 2 11 Comply with Local and National Electrical Codes 2 12 Product Disposal 2 13 Hot S...

Page 6: ...dicators 4 3 4 2 Serverboard 4 4 Jumpers 4 5 CMOS Clear 4 5 4 3 Blade Unit Components 4 6 Memory Support 4 6 Hard Disk Drives 4 7 Chapter 5 BIOS 5 1 5 1 Introduction 5 1 System BIOS 5 1 How To Change...

Page 7: ...de module and blade enclosure is the chassis that the MicroBlades power supplies and MicroBlade modules are housed within Please refer to our web site for information on operating systems that have be...

Page 8: ...port up to 128 GB of DDR4 2133 2400 MHz speed 32 GB size 1 2 V voltage VLP ECC RDIMM memory Memory is interleaved which requires modules to be of the same size and speed There are four sockets and mem...

Page 9: ...actor so a standard 42U rack may accommodate up to seven enclosures with 196 blade modules or the equivalent of 196 1U servers With the inclusion of up to fourteen CMM modules and up to twenty eight G...

Page 10: ...Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support superm...

Page 11: ...ssistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis These wa...

Page 12: ...uipo considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encont...

Page 13: ...t u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE IN...

Page 14: ...250 V 20 A 250V 20A 250V 20A Warnung Dieses Produkt ist darauf angewiesen dass im Geb ude ein Kurzschluss bzw berstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung...

Page 15: ...ing Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system compon...

Page 16: ...es les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der l int rieur du chassis pour installer ou enlever des composants de syst me Waarschuwing Voordat u toegang nee...

Page 17: ...nd de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Waarschuwing Deze apparatuur mag alleen worden ge nstalleerd vervangen of hers...

Page 18: ...ceso a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L a...

Page 19: ...ichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers Attention Danger d explosion si la pile n est pas remplac e correctement Ne...

Page 20: ...y connection All connections must be removed to de energize the unit Warnung Dieses Ger t kann mehr als eine Stromzufuhr haben Um sicherzustellen dass der Einheit kein trom zugef hrt wird m ssen alle...

Page 21: ...ckplane when the system is operating Use caution when servicing Warnung Wenn das System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung...

Page 22: ...ud Comply with Local and National Electrical Codes Warning Installation of the equipment must comply with local and national electrical codes Warnung Die Installation der Ger te muss den Sicherheitsst...

Page 23: ...2 13 Chapter 2 Standardized Warning Statements...

Page 24: ...led according to all national laws and regulations Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Advertencia Al deshacerse por completo de este...

Page 25: ...Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing Warnung Die L fter drehen sich u U noch wenn die L fterbaugruppe aus dem Chassis genommen wird Halten S...

Page 26: ...hassis Houd uw vingers schroevendraaiers en eventuele andere voorwerpen uit de buurt van de openingen in de ventilatorbehuizing Power Cable and AC Adapter Warning When installing the product use the p...

Page 27: ...s y adaptadores de CA La utilizaci n de otros cables y adaptadores podr a ocasionar un mal funcionamiento o un incendio Aparatos El ctricos y la Ley de Seguridad del Material proh be el uso de UL o CS...

Page 28: ...MBI 6218G T41X MicroBlade Module User s Manual 2 18 UL CSA Supermicro UL CSA...

Page 29: ...de meegeleverde of aangewezen kabels stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet...

Page 30: ...MBI 6218G T41X MicroBlade Module User s Manual 2 20...

Page 31: ...on and off independently from the rest of the MicroBlade modules installed in the same enclosure A MicroBlade module unit may be powered up in two ways Press the power button on the MicroBlade module...

Page 32: ...te MicroBlade modules can be hot plugged from the enclosure Installing a Blade Unit into the Enclosure Use the procedure below to install a blade unit into an enclosure Installing a MicroBlade Module...

Page 33: ...removed from the MicroBlade module If this battery dies it must be replaced with an equivalent CR2032 Lithium 3V battery Dispose of used batteries according to the manufacturer s instructions See Figu...

Page 34: ...d memory bandwidth it is strongly recommended that ALL memory slots in this MicroBlade module be populated by DIMMs DIMM layout is shown below in Figure 3 3 Note Though multiple DIMM memory module typ...

Page 35: ...ed without powering down the blade unit they reside in A blade module needs a hard disk drive with an operating system installed to operate RAID 0 1 and 10 are supported 3 6 Installing the Operating S...

Page 36: ...in BIOS must be enabled 2 A PXE server has been configured this can be another blade in the system 3 The PXE server must be connected over a network to the blade to be booted 4 The blade has only non...

Page 37: ...4 1 MBI 6218G T41X Blade Unit Features Feature Description Processors Supports a single Intel Xeon D 1541 embedded in a FCBGA 1667 socket on the serverboard Memory Each of the two nodes supports up t...

Page 38: ...ll blink until the last node out of the four is ready 3 KVM UID LED Blue Steady On Indicates that KVM has been initialized on this blade module Flashing Serves as a UID indicator the UID function is a...

Page 39: ...turn green To turn off press and hold the power button for 4 seconds and the power LED will turn orange LED Indicators Blade module LEDs are described below in Table 4 3 Table 4 3 Blade Module LED Ind...

Page 40: ...de module unit is a proprietary design which is based on the Intel Intel Xeon D 1541 processor See Figure 4 4 for a block diagram of this chipset Figure 4 3 for a view of the B1SD2 TF serverboard and...

Page 41: ...clear any passwords JBT1 consists of two contact pads located near the BIOS chip Clearing CMOS 1 First power down the blade and remove it from the enclosure 2 Short the CMOS pads with a metal object...

Page 42: ...module supports up to 32 GB of VLP ECC RDIMM 32 GB size DIMM memory in four 4 288 pin sockets See Section 3 4 Memory Installation on page 3 4 for further details on serverboard memory installation Tab...

Page 43: ...ives cannot be removed or replaced without powering down the blade unit they reside in See Chapter 1 for information on RAID Setup WARNING Enterprise level hard disk drives are recommended for use in...

Page 44: ...MBI 6218G T41X MicroBlade Module User s Manual 4 8 Notes...

Page 45: ...y little electrical power When the blade unit is turned off a backup battery provides power to the BIOS flash chip enabling it to retain system parameters Each time the blade is powered on it is confi...

Page 46: ...OS update simply follow the Help instructions in the IPMI BIOS Upload page Figure 5 1 when you press the Help button at the top of the page This procedure will get you a BIOS Update 5 3 Running Setup...

Page 47: ...an be activated in one of two ways 1 By pressing DELETE immediately after turning the system on or 2 When the message Press the Delete key to enter Setup appears briefly at the bottom of the screen du...

Page 48: ...ress the ENTER key to access the submenu Menu options found in the MAIN BIOS SETUP menu are described in Table 5 1 Figure 5 2 BIOS Setup Screen Table 5 1 Main BIOS Setup Menu Options Menu Option Descr...

Page 49: ...hlighting the setting option using the arrow keys and pressing ENTER Table 5 2 describes all sub menus found in the ADVANCED SETUP menu Figure 5 3 Advanced Setup Screen Table 5 2 Advanced Setup Menu O...

Page 50: ...he Power on state for the Numlock key The options are Off and On Wait for F1 If Error Use this feature to force the system to wait until the F1 key is pressed if an error occurs The options are Disabl...

Page 51: ...o enable 0 means all cores with 8 cores available Default is 0 Monitor Mwait Select Enabled to implement the Mwait instruction along with the Monitor instruction to allow the processor to specify the...

Page 52: ...icient P State This feature allows you to enable disable the energy efficient P state feature Options include either Enable or Disable Boot Performance Mode This feature selects the performance state...

Page 53: ...ptions include either Enable or Disable Energy Performance BIAS Setting This setting which is only active when you select the disable option from Energy Performance Tuning sets the Energy Performance...

Page 54: ...Enable or Disable Intel VT for Directed I O VT d This submenu brings up settings for the Intel VT for Directed I O VT d configuration Intel VT for Directed I O VT d This feature enables disables the I...

Page 55: ...cted on a read transaction Options include Disable or Enable Device Tagging Use this setting to enable or disable tagging of the memory device that generates stuck bits of hard errors South Bridge Con...

Page 56: ...disabled all drives will spin up at boot The options for this setting are Enabled and Disabled SATA0 SATA1 SATA2 SATA3 SATA4 Port SATA Device Type This setting allows you to specify the selected port...

Page 57: ...his setting selects the onboard video firmware type to be loaded Options include Disabled Legacy and EFI VGA Priority This feature allows you to select the graphics adapter to be used as the primary b...

Page 58: ...can be sent along with regular data bits to detect data transmission errors Select Even if the parity bit is set to 0 and the number of 1 s in data bits is even Select Odd if the parity bit is set to...

Page 59: ...e COM1 and SOL for Console Redirection Terminal Type This feature allows the user to select the target terminal emulation type for Console Redirection Select VT100 to use the ASCII character set Selec...

Page 60: ...imer HPET that produces periodic interrupts at a much higher frequency than a Real time Clock RTC does in synchronizing multimedia streams providing smooth playback and reducing the dependency on othe...

Page 61: ...Express errors Options are either No or Yes Erase Event Log If No is selected data stored in the event log will not be erased Select Yes Next Reset data in the event log will be erased upon next syst...

Page 62: ...eatures of the System Event Logging during boot The options are Enabled and Disabled Erase SEL Use this setting to erase SEL Options are either Yes or No When SEL is Full Use this option to choose the...

Page 63: ...ed IP addresses automatically if DHCP is selected Station IP Address This item displays the Station IP address for this computer This should be in decimal and in dotted quad form i e 192 168 10 253 Su...

Page 64: ...Platrom Key PK and the CSM function is disabled The options include Disabled and Enabled Secure Boot Mode This is a Secure Boot Mode selector Custom mode enables you to change the image execution pol...

Page 65: ...n Table 5 19 Boot Setup Menu Options Menu Option Description Setup Prompt Timeout This number field sets the number of seconds to wait for the setup activation key 65535 0xFFFF means indefinite waitin...

Page 66: ...BIOS settings are described in Table 5 21 below Network Device BBS Priorities This submenu allows you to set the order of the legacy devices in this group for setting the boot order UEFI Application B...

Page 67: ...save changes done so far to any of the setup options Discard Changes Highlight this item and hit ENTER to discard cancel any changes you made You will remain in the Setup utility Restore Defaults Hig...

Page 68: ...MBI 6218G T41X MicroBlade Module User s Manual 5 24 Notes...

Page 69: ...ndicate the task the system is currently executing Checkpoints are very useful in aiding software developers or technicians in debugging problems that occur during the pre boot process 1 1 Checkpoint...

Page 70: ...n after microcode loading 0x0A OEM initialization after microcode loading 0x0B Cache initialization 0x0C 0x0D Reserved for future AMI SEC error codes 0x0E Microcode not found 0x0F Microcode not loaded...

Page 71: ...itialization 0x35 CPU post memory initialization Boot Strap Processor BSP selection 0x36 CPU post memory initialization System Management Mode SMM initialization 0x37 Post Memory North Bridge initiali...

Page 72: ...PL 0xE1 S3 Boot Script execution 0xE2 Video repost 0xE3 OS S3 wake vector call 0xE4 0xE7 Reserved for future AMI progress codes S3 Resume Error Codes 0xE8 S3 Resume Failed 0xE9 S3 Resume PPI not Found...

Page 73: ...e Services 0x63 CPU DXE initialization is started 0x64 CPU DXE initialization CPU module specific 0x65 CPU DXE initialization CPU module specific 0x66 CPU DXE initialization CPU module specific 0x67 C...

Page 74: ...ion 0x79 CSM initialization 0x7A 0x7F Reserved for future AMI DXE codes 0x80 0x8F OEM DXE initialization codes 0x90 Boot Device Selection BDS phase is started 0x91 Driver connecting is started 0x92 PC...

Page 75: ...System Reset 0xB4 USB hot plug 0xB5 PCI bus hot plug 0xB6 Clean up of NVRAM 0xB7 Configuration Reset reset of NVRAM settings 0xB8 0xBF Reserved for future AMI codes 0xC0 0xCF OEM BDS initialization c...

Page 76: ...not be met Table 1 7 ACPI ASL Checkpoints Status Codes Description 0x01 System is entering S1 sleep state 0x02 System is entering S2 sleep state 0x03 System is entering S3 sleep state 0x04 System is e...

Page 77: ...anges Status Codes Description 0x05 OEM SEC initialization before microcode loading 0x0A OEM SEC initialization after microcode loading 0x1D 0x2A OEM pre memory initialization codes 0x3F 0x4E OEM PEI...

Page 78: ...MBI 6218G T41X MicroBlade Module User s Manual 1 10 Notes...

Page 79: ...ected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such...

Page 80: ...MBI 6218G T41X MicroBlade Module User s Manual 0 2 MBI 6218G T41X...

Reviews: