background image

Microserver

K1048-RT

USER’S MANUAL

Revision 1.0c

Summary of Contents for K1048-RT

Page 1: ...Microserver K1048 RT USER S MANUAL Revision 1 0c...

Page 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limit...

Page 3: ...ncluded with the server system and describes the main features of the mainboard and the SC801LTS R406KP chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the...

Page 4: ...tailed information on the SC801LTS R406KP server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring drives and when replacing system power supply...

Page 5: ...v Notes Preface...

Page 6: ...4 Contacting Supermicro 1 6 Chapter 2 Server Installation 2 1 Overview 2 1 2 2 Unpacking the System 2 1 2 3 Preparing for Setup 2 1 Choosing a Setup Location 2 2 2 4 Warnings and Precautions 2 2 Rack...

Page 7: ...e Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cable and AC Adapter 4 18 Chapter 5 Microserver System Setup 5 1 Rear I O Port...

Page 8: ...ver User s Manual Appendix B Storage Monitoring IPMI Page Using the IPMI Screen B 1 I2C Commands B 2 OEM IPMI Commands to Get Ethernet Hard Drive Information B 2 Standards B 2 Byte Range B 3 IP Addres...

Page 9: ...of the overview IP assignment flow for this switch storage server is shown below Chapter 1 Introduction 1 1 Storage System Manager Object Storage Platform Using the API this platform sets fault tolera...

Page 10: ...nication chips and system for communicating and servicing the Ethernet hard disk drives Although these systems are mounted on a system mainboard this mainboard does not contain any CPUs chipset or mem...

Page 11: ...com or see http www supermicro com solutions ManagementSoftware cfm for more details 1 3 Server Chassis Features The following is a general outline of the main features of the SC801 server chassis Sy...

Page 12: ...are also included I O Ports The SC801 chassis designed to be used in a 1U rackmount configuration The SC801 chassis provides four 1 10G Ethernet using RJ45 copper connectors and an IPMI Ethernet port...

Page 13: ...PHY 1G PHY 1G PHY 10G Switch 10G PHY I2C I2C WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD WKHUQHW HDD LAN 10Gb RJ...

Page 14: ...Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support super...

Page 15: ...any way If the server itself shows damage you should file a damage claim with the carrier who delivered it Decide on a suitable location for the rack unit that will hold the K1048 RT server It should...

Page 16: ...ck installation stabilizers should be attached to the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the...

Page 17: ...i unit rack assembly the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room Therefore consideration should be given to installing the equipme...

Page 18: ...the market which may mean that the assembly procedure differs slightly You should also refer to the installation instructions that came with the rack unit you are using Note These rails will fit a ra...

Page 19: ...BACK INTERMEDIATE MEMBER PUSH THE YELLOW PIECE BACKWARD AND PULL THE BRACKET TO PASS THE SLOT PULL YELLOW PIECE FORWARD TO SECURE THE BRACKET PUSH THE REAR BACKET BACK AND REPEAT THE SAME STEPS PRESS...

Page 20: ...sh the server completely into the rack 3 Optional Insert and tighten the thumbscrews that hold the front of the server to the rack Note The figure above is for illustrative purposes only Always instal...

Page 21: ...Push on Power button Button LED turns green Drives spin up switch initializes Depending on environmental temperature Fans may not spin up like a typical server power up 15 30 seconds after power butt...

Page 22: ...2 8 K1048 RT Microserver User s Manual Notes...

Page 23: ...LEDs on the control panel and on the drive carriers to keep you constantly informed of the overall status of the system The chassis includes A control panel on the front that includes power buttons a...

Page 24: ...urning off system power with this button removes the main power but maintains standby power Reset The reset button is used to reboot the system NIC Indicates network activity when flashing UID LED The...

Page 25: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Page 26: ...onsidere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el...

Page 27: ...l kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard proc...

Page 28: ...en des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher...

Page 29: ...erstromschutz installiert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuito...

Page 30: ...e power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 250V 20A Waarschuwing Dit product is afhankelijk van de kortsluitbeveil...

Page 31: ...tado de los m dulos de fuente de alimentaci n antes de tener acceso el interior del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sourc...

Page 32: ...nung Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o ut...

Page 33: ...eug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m glich Advertencia Esta unidad ha sido dise ada para instalaci n en reas de acceso restringido S lo puede obtenerse acceso a una d...

Page 34: ...e or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een be...

Page 35: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Page 36: ...len dass der Einheit kein trom zugef hrt wird m ssen alle Verbindungen entfernt werden Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo...

Page 37: ...System in Betrieb ist treten auf der R ckwandplatine gef hrliche Spannungen oder Energien auf Vorsicht bei der Wartung Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero...

Page 38: ...Installation der Ger te muss den Sicherheitsstandards entsprechen Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigh...

Page 39: ...onal laws and regulations Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Attention L quipement doit tre install conform ment aux normes lectriqu...

Page 40: ...e de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning The fans might still be tu...

Page 41: ...tfernt Advertencia Los ventiladores podran dar vuelta cuando usted quite ell montaje del ventilador del chasis Mandtenga los dedos los destornilladores y todos los objetos lejos de las aberturas del v...

Page 42: ...SA Supermicro UL CSA UL CSA Warnung Bei der Installation des Produkts die zur Verf gung gestellten oder benannt Anschlusskabel Stromkabel und Netzteile Verwendung anderer Kabel und Adapter kann zu ein...

Page 43: ...s dispositivos el ctricos que los productos designados por Supermicro solamente Attention Lors de l installation du produit utilisez les bables de connection fournis ou d sign L utilisation d autres c...

Page 44: ...els stroomkabels en adapters Het gebruik van andere kabels en adapters kan leiden tot een storing of een brand Elektrisch apparaat en veiligheidsinformatiebladen wet verbiedt het gebruik van UL of CSA...

Page 45: ...ave finished working with the mainboard to better cool and protect the system 5 1 Rear I O Ports See Figure 5 1 below for the locations of the various I O ports Back Panel I O Port Locations and Defin...

Page 46: ...efore installing or removing any components 3 Changing BMC IP address and log in information is required to avoid address conflicts if setting up more than one unit on your network 4 Upon system bootu...

Page 47: ...hernet ports accept RJ45 type cables Note Please refer to the LED Indicator Section for LAN LED information Fan Header Pin Definitions Pin Definition 1 Ground 2 12V 3 Tachometer 4 Firmware Thermal Con...

Page 48: ...eed Left 100 Mb s Amber Blinking Activity Right Active IPMI LAN Activity LED Link LED LAN LEDs The Ethernet LAN port is located on the IO Backplane on the mainboard Each LAN port has two LEDs The Yell...

Page 49: ...r CR2032 Dispose of used batteries according to the manufacturer s instructions Figure 5 9 Installing the Onboard Battery Please handle used batteries carefully Do not damage the battery in any way a...

Page 50: ...5 6 K1048 RT Microserver User s Manual Notes...

Page 51: ...o prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions...

Page 52: ...t down carefully grasp the head of the power cord and gently pull it out of the back of the power supply If your system has dual power supplies remove the cords from both power supplies 3 Disconnect t...

Page 53: ...of the chassis Removing a Chassis Cover 1 Loosen the two thumb screws on the front or rear of the chassis 2 Slide the cover away from the middle and off Caution Except for short periods of time do not...

Page 54: ...est on metal brackets that runs the full width of the chassis They attach to the system by means of cables individually connecting power and Ethernet using standard SAS HDD connectors Ethernet drives...

Page 55: ...1 Remove front HDD cover from the chassis Figure 6 2 2 Locate and press the latch down on the HDD you wish to remove from the chassis Figure 6 3 and Figure 6 4 3 Disconnect the drive connection from...

Page 56: ...6 6 K1048 RT Microserver User s Manual Figure 6 5 Chassis and HDD Mounting Brackets Chassis Mounting Bracket HDD Mounting Bracket...

Page 57: ...system 3 Remove the failed fan s power cable from the mainboard 4 Remove the four pins securing the fan to the fan housing 5 Lift the failed fan from the fan housing and out of the chassis 6 Place th...

Page 58: ...en light indicates that the power supply is operating Replacement units can be ordered directly from Supermicro Replacing the Power Supply 1 Remove the AC power cord from the back of the power supply...

Page 59: ...ooling The system has six 6 8 cm PWM system cooling fans Note The system cooling fans are NOT redundant hot plug System Input Requirements AC Input Voltage 100 240 V Rated Input Current 6 3 Amp Rated...

Page 60: ...EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 EN 61000 4 11 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe California Best Management Practices Regulations for Perch...

Page 61: ...ollow the procedure below for using the Storage Monitoring IPMI page for the K1048 RT Using the Storage Monitoring Page 1 Click on Storage Monitoring to bring up the Storage Monitoring page 2 Click on...

Page 62: ...0 Reset Device 0x12 Set Device IP Address 0x13 Get Device Network MAC 0x14 Get Interface Link State 0x15 Get Firmware Version 0x16 Get Data Protocol Version OEM IPMI Commands to Get Ethernet Hard Driv...

Page 63: ...N 21 34 N A Unused 35 Hex Temperature 35 41 N A Unused 42 45 Hex HDD FW version 45 N A Unused 46 48 Hex Command set version 49 N A Unused 50 81 Hex Extended status 82 97 Hex Manufacturer 98 113 Hex Pr...

Page 64: ...yte of IP info from 114 251 IP Address Info Byte Interface Definition 114 Interface 0 Status 115 118 Ipv4 gateway 132 135 Ipv4 address 149 164 Ipv6 gateway 166 181 Ipv6 address 183 Interface 1 Status...

Page 65: ...akdown of 12 byte of MAC info from 265 276 MAC Address Info Byte Interface Definition 265 270 Interface 0 MAC address 271 276 Interface 1 Mac Address An example of a raw command to collect drive mac a...

Page 66: ...form be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such pro...

Reviews: