background image

USER’S MANUAL

Revision 1.0c

SC847 JBOD  

Storage Enclosure Series

CSE-847E1C-R1K23JBOD  CSE-847E2C-R1K23JBOD 

Summary of Contents for CSE-847E1C-R1K23JBOD

Page 1: ...USER S MANUAL Revision 1 0c SC847 JBOD Storage Enclosure Series CSE 847E1C R1K23JBOD CSE 847E2C R1K23JBOD...

Page 2: ...all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A or Class B digital device pursuant to...

Page 3: ...ailable when this document was published Refer to the Supermicro web site for updates on supported parts and configurations This manual may be periodically updated without notice Please check the Supe...

Page 4: ...t Standardized Warning Statements 2 1 Warning Definition 2 1 Installation Instructions 2 4 Circuit Breaker 2 5 Power Disconnection Warning 2 6 Equipment Installation 2 8 Restricted Area 2 9 Battery Ha...

Page 5: ...5 4 4 Removing the Chassis Cover 4 7 4 5 Installing Hard Drives 4 8 4 6 System Fans 4 11 4 7 Power Supply 4 13 4 8 Control Board 4 15 4 9 Removing and Installing the Backplanes 4 16 Chapter 5 Rack Ins...

Page 6: ...delines 6 2 6 3 Components Connectors Jumpers and LEDs 6 2 Component and Connector Definitions 6 3 Jumpers and LED Indicators 6 4 6 4 I2 C Cabling to the Backplane 6 6 6 5 JBOD Power Up Power Down Seq...

Page 7: ...The chassis is equipped with a redundant efficient power supply for outstanding power savings with specially designed optimized cooling Quick release tool less slide rails are available for quick ins...

Page 8: ...nnectors Control Board The JBOD control board allows the user to remotely control and monitor the chassis resources using BMC such as powering on or off controlling fan speeds and reading temperature...

Page 9: ...must be mailed when service is complete For faster service RMA authorizations may be requested online http www supermicro com support rma Whenever possible repack the chassis in the original Supermicr...

Page 10: ...pe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro...

Page 11: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Th...

Page 12: ...ere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el text...

Page 13: ...k letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaa...

Page 14: ...des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher le...

Page 15: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Page 16: ...or es Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system comp...

Page 17: ...r del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der...

Page 18: ...Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utiliza...

Page 19: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Page 20: ...equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperk...

Page 21: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Page 22: ...fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer to...

Page 23: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Page 24: ...cal codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Backplane...

Page 25: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Page 26: ...tos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent...

Page 27: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Page 28: ...kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen e...

Page 29: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Page 30: ...2 20 SC847 JBOD Chassis Manual Notes...

Page 31: ...The server includes a control panel on the front that houses power buttons and status monitoring lights The externally accessible hard drives display status lights The power supply displays status lig...

Page 32: ...Panel Buttons The chassis includes two push buttons that control power to the system Power Indicates power is being supplied to the system power supply units This LED is illuminated when the system is...

Page 33: ...se this function to locate the server in a rack mount environment Blinking blue Remote UID is on Use this function to identify the server from a remote location Power Fail Indicates a power supply mod...

Page 34: ...ure Red Blinking RAID activity When the red LED is blinking it indicates that the system is either building initializing or rebuilding RAID 3 5 Power Supply LEDs On the rear of the power supply module...

Page 35: ...n the chassis The only tool required is a Phillips screwdriver Review the warnings and precautions listed in the manual before setting up or servicing this chassis These include information in Chapter...

Page 36: ...tes the power up sequence in three seconds After Normal Shutdown by BMC or Power Button Press the power button once The JBOD control board will initiate the power up sequence in three seconds After a...

Page 37: ...r Figure 4 2 For more information on the BMC see Section 6 6 in this manual Removing Power from the System Before performing most setup or maintenance tasks use the following procedure to ensure that...

Page 38: ...ode host bus adapter HBA card to the two Primary receptacles marked In If using the E2C model CSE 847E2C R1K23JBOD for redundancy connect two more mini SAS HD cables to the two Secondary receptacles a...

Page 39: ...e Single HBA Cascading Storage The following diagram shows a server with a single host bus adapter HBA and requires only the primary expander on the backplane The SC847 JBOD storage enclosure model E1...

Page 40: ...following diagram shows a server with dual HBAs and requires the primary and secondary expanders on the backplane The SC847 JBOD storage enclosure model E2C accommodates this configuration HBA SC847...

Page 41: ...he back of the power supplies 2 Press the release tabs to remove the cover from the locked position Press both tabs at the same time 3 Once the top cover is released from the locked position slide the...

Page 42: ...on Except for short periods of time such as swapping hard drives do not operate the server with the hard drive bays empty Removing Hard Drive Carriers from the Chassis 1 Press the release button on th...

Page 43: ...Remove the two screws securing the dummy drive to the drive carrier and remove the dummy drive 2 Slide the hard drive into the carrier with the printed circuit board side facing down Figure 4 8 Removi...

Page 44: ...ecure the hard drive to the carrier using six screws 5 Replace the drive carrier into the chassis Make sure to close the drive carrier handle to lock the drive carrier into place Drive Carrier SAS SAT...

Page 45: ...ended period of time with the chassis open 2 Remove the failed fan s power cord from the JBOD control board 3 Press the fan release tab to lift the failed fan from the chassis and pull it completely f...

Page 46: ...SC847 JBOD Chassis Manual 4 12 Figure 4 13 Placing a Mid chassis Fan...

Page 47: ...00 120v or 180 240v An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Figure 4 14 Power Supply Changi...

Page 48: ...SC847 JBOD Chassis Manual 4 14 Figure 4 15 Power Supply Release Tab Release Tab...

Page 49: ...board CSE PTJBOD CB3 allows the user to remotely control and monitor the chassis resources using the BMC such as powering on or off controlling fan speeds and reading temperature data from the backpla...

Page 50: ...the Front Backplane 1 Power down the system and remove the power cords from the rear of the power supplies Remove the chassis cover 2 Remove the two side screws securing the front backplane to the cha...

Page 51: ...e of the chassis which secure the rear tray to the chassis 3 Pull the rear tray out of the back of the chassis as illustrated Figure 4 20 Removing the Three Screws Securing the Backplane Figure 4 19 R...

Page 52: ...Securing the Front Backplane 1 3 1 4 Figure 4 21 Installing the Front Backplane 1 2 3 Install the two side screws to secure the front backplane to the chassis 4 Install the four horizontal screws alon...

Page 53: ...4 24 Installing the Screws Securing the Rear Backplane Figure 4 23 Installing the Rear Backplane 1 3 1 2 3 Place the rear backplane in the chassis and secure it with the three vertical screws along t...

Page 54: ...SC847 JBOD Chassis Manual 4 20 Notes...

Page 55: ...Avoid areas where heat electrical noise and electromagnetic fields are generated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail assembli...

Page 56: ...verextended Have a rack lift in place as a precaution in case the test fails In any instance of pulling the system from the rack always use a rack lift and follow all associated safety precautions Gen...

Page 57: ...sideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounde...

Page 58: ...tly to the chassis an outer rail that secures to the rack and a middle rail which extends from the outer rail These assemblies are specifically designed for the left and right side of the chassis and...

Page 59: ...from coming completely out of the rack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails 1 Pull the inner rail out...

Page 60: ...the hooks of the chassis with the inner rail holes Make sure the rail faces outward so that it will fit with the rack s mounting bracket 2 Slide the rail toward the front of the chassis to hook the i...

Page 61: ...5 7 Chapter 5 Rack Intallation 1 1 1 2 1 3 Warning Do not pick up the server by the front handles They are designed to pull the system from a rack only...

Page 62: ...rails to the rack 4 Pull out the rear of the outer rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square hole...

Page 63: ...even on both both sides You may have to depress the locking tabs while inserting When the server has been pushed completely into the rack the locking tabs should click into the locked position 3 If s...

Page 64: ...avy chassis from the rack without assistance Be sure to have sufficient assistance supporting the chassis when removing it from the rack Use a lift Removing the Chassis from the Rack 1 Pull the chassi...

Page 65: ...permicro web site at www supermicro com for the latest updates compatible parts and supported configurations 6 2 Safety Guidelines ESD Safety Guidelines Electrostatic Discharge ESD can damage electron...

Page 66: ...5 6 1 3 1 3 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 24 13 12 1 A 1 E 3 K 7 9 R 3 2 1 1 2 3 1 2 7 8 1 2 7 8 1 2 7 8 1 2 7 8 1 2 19 20 1 5 1 5 6 9 1 2 10 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 1 7 6 12 15 17...

Page 67: ...he chassis using cable CBL NTWK 0584 or CBL NTWK 0587 8 Control Panel Connector This connector is designated JF1 and connects to the control panel on the chassis See Chapter 3 for additional control p...

Page 68: ...To enable SAS2 or SAS3 functionality on the I2 C connectors set the JP5 jumper as noted 1 2 5 6 1 3 1 3 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 24 13 12 1 A 1 E 3 K 7 9 R 3 2 1 1 2 3 1 2 7 8 1 2 7 8 1 2 7 8 1...

Page 69: ...1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 1 7 6 12 15 17 13 14 16 19 18 A C A C A E K R Y 1 5 10 20 12 13 24 25 36 37 48 MH2 MH4 JP6 U U18 U17 U16 U14 U13 JP7 JP5 JP1 JP2 JP3 JP4 JPW1 BT1 C10 Y2 U9 MH3 MH1 C...

Page 70: ...U16 U14 U13 JP7 JP5 JP1 JP2 JP3 JP4 JPW1 BT1 C10 C146 Y2 U9 MH3 MH1 J4 J6 J7 J5 U10 JF1 Q19 Q18 Q13 JPI2C1 J3 J2 U12 U11 C8 C9 FAN1 FAN2 FAN3 FAN4 FAN5 FAN6 FAN7 FAN8 FAN10 FAN9 J8 U8 Q3 Q16 R138 C14...

Page 71: ...initiates the power up sequence in three seconds After Normal Shutdown by BMC or Power Button Press the power button once The JBOD control board will initiate the power up sequence in three seconds Af...

Page 72: ...The sticker also displays the BMC MAC address Figure 6 5 BMC Password Label IP Address The default IP address configuration mode is Dynamic Host and Configuration Protocol DHCP When connected to the...

Page 73: ...of finding the IP address 1 Identify the JBOD enclosure name for example dev sg4 2 Use the vpd command to view the IP address root hdmaster user sg_vpd p 0x85 dev sg4 Management network addresses VPD...

Page 74: ...6 10 SC847 JBOD Chassis Manual Notes...

Page 75: ...y Specifications This appendix lists power supply specifications for your chassis system 1200W Redundant Supermicro Part PWS 1K23A 1R with PDB AC Input 100 240 V 4 5 11 Amp 50 60 Hz DC Output 12V 1000...

Page 76: ...SC847 JBOD Chassis Manual A 2...

Page 77: ...4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 8 BS EN 61000 4 11 Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35...

Page 78: ...e reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products...

Page 79: ...om ESD Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not t...

Page 80: ...l reflects BPN SAS3 846EL Revision 1 01 the most current release available at the time of publication Always refer to the Supermicro Web site at www supermicro com for the latest updates compatible pa...

Page 81: ...20 MH19 MH18 MH17 MH16 ACTLED HS2 HS1 J30 JP3 J31 JP4 J24 J29 U51 Q873 Q866 Q872 Q871 Q868 Q867 Q870 Q869 U25 U20 U29 U26 U27 U28 U31 U30 U37 U33 U1 EC23 C382 C383 EC9 EC8 EC7 EC6 EC5 EC4 EC3 EC2 EC12...

Page 82: ...ors are designated J49 and J50 The secondary SAS Ports are designated J51 through J52 and are not pres ent on EL1 single port backplanes 6 7 Primary and Secondary UART Con nectors The primary UART con...

Page 83: ...51 Q873 Q866 Q872 Q871 Q868 Q867 Q870 Q869 U25 U20 U29 U26 U27 U28 U31 U30 U37 U33 U1 EC23 C382 C383 EC9 EC8 EC7 EC6 EC5 EC4 EC3 EC2 EC12 EC11 EC10 EC1 EC24 EC22 EC21 EC20 EC19 EC18 EC17 EC16 EC15 EC1...

Page 84: ...G8 E7 G7 H7 H8 E8 PRESS FIT CG5 CG2 BPN SAS3 846EL2 REV 1 01 DESIGNED IN USA 1 1 4 1 4 1 4 1 4 1 4 1 4 14 6 7 8 13 2 6 7 8 9 13 11 12 22 11 12 22 11 11 12 22 11 12 22 11 12 22 12 13 14 23 2 11 12 13...

Page 85: ...17 ACT16 B ACT 3 FAIL 3 ACT 2 FAIL 2 ACT 7 FAIL 7 ACT 6 FAIL 6 1 SAS 0 SAS 6 SAS 7 SAS 13 SAS SAS 12 ACT 12 FAIL 12 FAIL 13 ACT 13 ACT 18 FAIL 18 ACT 19 FAIL 19 SAS 18 SAS 19 ACT 23 FAIL 23 ACT 22 FAI...

Page 86: ...T4 FAIL4 SAS 5 ACT5 FAIL5 SAS 6 ACT6 FAIL6 SAS 7 ACT7 FAIL7 SAS 8 ACT8 FAIL8 SAS 9 ACT 9 FAIL9 SAS 10 ACT10 FAIL10 SAS 11 ACT11 FAIL11 SAS 12 ACT12 FAIL12 SAS 13 ACT13 FAIL13 SAS 14 ACT14 FAIL14 SAS 1...

Page 87: ...D8 CG4 E1 E2 G2 F2 F1 H2 H1 G1 F7 F8 G8 E7 G7 H7 H8 E8 PRESS FIT CG5 CG2 A1 A2 A7 A8 CG1 B1 B2 B7 B8 C1 C2 C7 C8 D1 D2 D7 D8 CG4 E1 E2 G2 F2 F1 H2 H1 G1 F7 F8 G8 E7 G7 H7 H8 E8 PRESS FIT CG5 CG2 BPN S...

Page 88: ...gle host bus configuration the backplane connects to one host bus adapter Single Host Bus Adapter Failover If the expander or data path in Port A fails the system automatically switches to Port B with...

Page 89: ...CG5 CG2 A1 A2 A7 A8 CG1 B1 B2 B7 B8 C1 C2 C7 C8 D1 D2 D7 D8 CG4 E1 E2 G2 F2 F1 H2 H1 G1 F7 F8 G8 E7 G7 H7 H8 E8 PRESS FIT CG5 CG2 BPN SAS3 846EL2 REV 1 01 DESIGNED IN USA 1 1 4 1 4 1 4 1 4 1 4 1 4 14...

Page 90: ...C383 EC9 EC8 EC7 EC6 EC5 EC4 EC3 EC2 EC12 EC11 EC10 EC1 EC24 EC22 EC21 EC20 EC19 EC18 EC17 EC16 EC15 EC14 EC13 J48 J47 L8 L10 L4 L2 L5 L6 PWR1 PWR2 PWR3 PWR4 PWR5 PWR6 R65 TP95 TP94 TP15 TP36 C128 C1...

Page 91: ...r 36 pin at one end and a Mini SAS HD SFF 8643 connector at the other end It connects from the SAS2 HBA to the BPN SAS3 846EL model backplane Cable name Internal HD Mini SAS to HD Mini SAS Part CBL SA...

Page 92: ...4 E1 E2 G2 F2 F1 H2 H1 G1 F7 F8 G8 E7 G7 H7 H8 E8 PRESS FIT CG5 CG2 A1 A2 A7 A8 CG1 B1 B2 B7 B8 C1 C2 C7 C8 D1 D2 D7 D8 CG4 E1 E2 G2 F2 F1 H2 H1 G1 F7 F8 G8 E7 G7 H7 H8 E8 PRESS FIT CG5 CG2 A1 A2 A7 A...

Page 93: ...EC1 EC24 EC22 EC21 EC20 EC19 EC18 EC17 EC16 EC15 EC14 EC13 J48 J47 L8 L10 L4 L2 L5 L6 PWR1 PWR2 PWR3 PWR4 PWR5 PWR6 R65 TP95 TP94 TP15 TP36 C128 C135 C233 C236 C206 C24 CS21 CT199 12V_LED2 5V_LED2 5V...

Page 94: ...escription Internal cable connects the SAS3 backplane to external ports Cable Name 1 Meter External Mini SAS HD to External Mini SAS HD Cable Part CBL SAST 0573 Ports Single Placement External Cable D...

Page 95: ...Channel Environment This section describes the cables used when cascading from dual HBAs These con nections use CBL SAST 0531 internal cables and CBL SAST 0573 external cables Figure C 17 Dual HBA Co...

Page 96: ...C 18 SC847E1C 2C JBOD Chassis Manual Cascading BPN SAS3 846EL and BPN SAS3 847EL For instructions on cascading BPN SAS3 846EL and BPN SAS3 847EL together see page Appendix E of this manual...

Page 97: ...om ESD Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing a component from the antistatic bag Handle the backplane by its edges only do not t...

Page 98: ...ects BPN SAS3 847EL Revision 1 00 the most current release available at the time of publication Always refer to the Supermicro Web site at www supermicro com for the latest updates compatible parts an...

Page 99: ...R459 R447 U9 U54 U53 U7 U52 U2 U47 U18 U32 U39 U17 U16 U14 U60 U59 U1 U46 TP31 TP30 PWR5 PWR4 PWR3 PWR2 PWR1 L5 L3 L12 J24 J34 EC9 EC8 EC7 EC6 EC5 EC4 EC3 EC24 EC23 EC22 EC21 EC20 EC2 EC19 EC18 EC17 E...

Page 100: ...3 The secondary SAS Ports are designated SEC_J0 J30 SEC_J1 J31 SEC_J2 J32 and are not present on EL1 single port backplanes 6 7 Primary and Secondary UART Con nectors The primary UART connector is des...

Page 101: ...present on BPN SAS3 847EL1 backplanes These are connectors for the manufacturer s test purposes only 14 15 ICE Connectors The Primary ICE connector is designated P_ICE J26 The secondary ICE connector...

Page 102: ...MH6 MH9 MH4 MH8 MH1 MH12 MH10 MH13 MH7 F14 F1 U3 C83 C354 C102 CT1 C280 C281 C233 R564 R459 R447 U9 U54 U53 U7 U52 U2 U47 U18 U32 U39 U17 U16 U14 U60 U59 U1 U46 TP31 TP30 PWR5 PWR4 PWR3 PWR2 PWR1 L5 L...

Page 103: ...1 4 1 4 1 4 1 8 9 2 1 9 2 1 1 1 4 1 2 3 4 1 2 3 BAR CODE A C A C A C A C A C DESIGNED IN USA BPN SAS3 847EL2 REV 1 00 A 1 E 5 H 5 1 A E H A 1 E 5 H A E H 24 2 11 12 13 14 23 24 11 12 13 14 23 1 5 10...

Page 104: ...AS SAS SAS SAS SAS 27 7 8 22 22 21 22 21 FAIL19 FAIL18 FAIL17 FAIL16 FAIL0 FAIL9 FAIL8 FAIL7 FAIL5 FAIL4 FAIL3 FAIL15 FAIL14 FAIL13 FAIL12 FAIL11 FAIL10 FAIL1 ACT19 ACT18 ACT17 ACT16 ACT13 ACT12 ACT0...

Page 105: ...FAIL1 SAS 2 ACT 2 FAIL2 SAS 3 ACT3 FAIL3 SAS 4 ACT4 FAIL4 SAS 5 ACT5 FAIL5 SAS 6 ACT6 FAIL6 SAS 7 ACT7 FAIL7 SAS 8 ACT8 FAIL8 SAS 9 ACT 9 FAIL9 SAS 10 ACT10 FAIL10 SAS 11 ACT11 FAIL11 SAS 12 ACT12 FAI...

Page 106: ...D 10 SC847E1C 2C JBOD Chassis Manual Notes...

Page 107: ...AS3 847EL1 backplanes have a single port expander that accesses all of the drives and supports cascading Figure D 6 BPN SAS3 847EL2 Dual Port Configuration To Lower Backplane in Cascaded System To Low...

Page 108: ...D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2...

Page 109: ...C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3...

Page 110: ...A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8...

Page 111: ...r 36 pin at one end and a Mini SAS HD SFF 8643 connector at the other end It connects from the SAS2 HBA to the BPN SAS3 847EL model backplane Cable name Internal HD Mini SAS to HD Mini SAS Part CBL SA...

Page 112: ...7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B...

Page 113: ...1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A...

Page 114: ...s the SAS3 backplane to external ports Also available without the LP bracket part number AOM SAS3 16I16E Cable Name 1 Meter External Mini SAS HD to External Mini SAS HD Cable Part CBL SAST 0573 Ports...

Page 115: ...A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1 C2 D1 D2 CG2 B7 B8 C8 A7 C7 D7 D8 A8 PRESS FIT CG3 CG4 A1 A2 CG1 B1 B2 C1...

Page 116: ...D 20 SC847E1C 2C JBOD Chassis Manual Cascading BPN SAS3 846EL and BPN SAS3 847EL For instructions on cascading BPN SAS3 846EL and BPN SAS3 847EL together see page Appendix E of this manual...