Supermicro CSE-216BE1C-R609JBOD User Manual Download Page 16

2-6

SC216B JBOD Chassis Manual

Power Disconnection Warning

 電源切断の警告

システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセス

するには、

システムの電源はすべてのソースから切断され、電源コードは電源モジュールから取り

外す必要があります。

警告

在你打开机箱并安装或移除内部器件前,必须将系统完全断电,并移除电源线。

警告

在您打開機殼安裝或移除內部元件前,必須將系統完全斷電,並移除電源線。

Warnung 
Das System muss von allen Quellen der Energie und vom Netzanschlusskabel 
getrennt sein, das von den Spg.Versorgungsteilmodulen entfernt wird, bevor es 

Warning!

The system must be disconnected from all sources of power and the power cord 
removed from the power supply module(s) before accessing the chassis interior to 
install or remove system components. 

경고!

이 제품은 전원의 단락(과전류)방지에 대해서 전적으로 건물의 관련 설비에 
의존합니다. 보호장치의 정격이 반드시 250V(볼트), 20A(암페어)를 초과하지 
않도록 해야 합니다.

Waarschuwing 
Dit product is afhankelijk van de kortsluitbeveiliging (overspanning) van 
uw electrische installatie. Controleer of het beveiligde aparaat niet groter 
gedimensioneerd is dan 220V, 20A.

Summary of Contents for CSE-216BE1C-R609JBOD

Page 1: ...USER S MANUAL Revision 1 0a SC216B JBOD Storage Enclosure Series CSE 216BE1C R609JBOD CSE 216BE2C R609JBOD...

Page 2: ...all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A or Class B digital device pursuant to...

Page 3: ...ailable when this document was published Refer to the Supermicro web site for updates on supported parts and configurations This manual may be periodically updated without notice Please check the Supe...

Page 4: ...bout Standardized Warning Statements 2 1 Warning Definition 2 1 Installation Instructions 2 4 Circuit Breaker 2 5 Power Disconnection Warning 2 6 Equipment Installation 2 8 Restricted Area 2 9 Battery...

Page 5: ...Cascading Storage 4 5 4 4 Removing the Chassis Cover 4 7 4 5 Installing Hard Drives 4 8 4 6 System Fans 4 10 4 7 Power Supply 4 12 Power Distributor 4 14 4 8 Control Board 4 15 4 9 Backplane 4 16 Chap...

Page 6: ...6 1 ESD Safety Guidelines 6 1 General Safety Guidelines 6 2 6 3 Components Connectors Jumpers and LEDs 6 2 Component and Connector Definitions 6 3 Jumpers and LED Indicators 6 4 6 4 I2 C Cabling to th...

Page 7: ...ipped with a redundant efficient power supply for outstanding power savings with specially designed optimized cooling Quick release tool less slide rails are available for quick installation Note A co...

Page 8: ...80 mm heavy duty hot swap fans System fans are powered and controlled by the BMC and 4 pin connectors Control Board The JBOD control board CSE PTJBOD CB3 allows the user to remotely control and monit...

Page 9: ...be prominently displayed on the outside of the shipping carton and mailed prepaid or hand carried Shipping and handling charges will be applied for all orders that must be mailed when service is compl...

Page 10: ...ope Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicr...

Page 11: ...for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis Th...

Page 12: ...dere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar el tex...

Page 13: ...k letsel kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaa...

Page 14: ...des Systems an die Stromquelle die Installationsanweisungen lesen Advertencia Lea las instrucciones de instalaci n antes de conectar el sistema a la red de alimentaci n Attention Avant de brancher le...

Page 15: ...ert ist Stellen Sie sicher dass der Nennwert der Schutzvorrichtung nicht mehr als 250 V 20 A betr gt Advertencia Este equipo utiliza el sistema de protecci n contra cortocircuitos o sobrecorrientes de...

Page 16: ...vor es Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system com...

Page 17: ...r del chasis para instalar o para quitar componentes de sistema Attention Le syst me doit tre d branch de toutes les sources de puissance ainsi que de son cordon d alimentation secteur avant d acc der...

Page 18: ...Das Installieren Ersetzen oder Bedienen dieser Ausr stung sollte nur geschultem qualifiziertem Personal gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utiliz...

Page 19: ...stallation in Bereichen mit beschr nktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schl ssel oder einer sonstigen Sicherheitsvorkehrung m gli...

Page 20: ...equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperk...

Page 21: ...ecommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrecta Reemplazar la bat...

Page 22: ...fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attention Cette unit peut avoir plus d une connexion d alimentation Pour supprimer to...

Page 23: ...ero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques circulent sur le fond de panier Prendre des pr cautions lors de la maintenanc...

Page 24: ...cal codes Warnung Die Installation der Ger te muss den Sicherheitsstandards entsprechen Advertencia La instalacion del equipo debe cumplir con las normas de electricidad locales y nacionales Backplane...

Page 25: ...ional laws and regulations Attention L quipement doit tre install conform ment aux normes lectriques nationales et locales Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lok...

Page 26: ...tos nacionales Attention La mise au rebut ou le recyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent...

Page 27: ...dedos los destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Il est possible que les ventilateurs soient toujours en rotation lorsque vous retirerez le bloc ventilat...

Page 28: ...r kann zu einer Fehlfunktion oder ein Brand entstehen Elektrische Ger te und Material Safety Law verbietet die Verwendung von UL oder CSA zertifizierte Kabel UL oder CSA auf der Code f r alle anderen...

Page 29: ...utres appareils lectriques que les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA UL CSA Supermicro UL CSA AC Electrical Appliance and Material Safety Law UL CSA UL CSA Waarschuwing Bi...

Page 30: ...2 20 SC216B JBOD Chassis Manual Notes...

Page 31: ...The server includes a control panel on the front that houses power buttons and status monitoring lights The externally accessible hard drives display status lights The power supply displays status lig...

Page 32: ...IPMI Reset Button Press briefly to toggle the UID alert light The blue LED will blink Press and hold 6 seconds to set the BMC IP address to 192 168 1 99 The blue LED will blink Press and hold 12 secon...

Page 33: ...e this function to locate the server in a rack mount environment Blinking blue Remote UID is on Use this function to identify the server from a remote location Power Fail Indicates a power supply modu...

Page 34: ...lure Red Blinking RAID activity When the red LED is blinking it indicates that the system is either building initializing or rebuilding RAID 3 5 Power Supply LEDs On the rear of the power supply modul...

Page 35: ...ance on the chassis The only tool required is a Phillips screwdriver Review the warnings and precautions listed in the manual before setting up or servicing this chassis These include information in C...

Page 36: ...tes the power up sequence in three seconds After Normal Shutdown by BMC or Power Button Press the power button once The JBOD control board will initiate the power up sequence in three seconds After a...

Page 37: ...r Figure 4 2 For more information on the BMC see Section 6 6 in this manual Removing Power from the System Before performing most setup or maintenance tasks use the following procedure to ensure that...

Page 38: ...ry receptacles marked In If using the E2C model CSE 216BE2C R609JBOD for redundancy connect two more mini SAS HD cables to the top two Secondary receptacles also marked In Cables are described in Appe...

Page 39: ...HD Cable SC216B JBOD SC216B JBOD Figure 4 4 Sample Cascading Storage Single HBA Cascading Storage The following diagram shows a server with a single host bus adapter HBA and requires only the primary...

Page 40: ...g Storage Dual HBAs HBA The following diagram shows a server with dual HBAs and requires the primary and secondary expanders on the backplane The SC216B JBOD storage enclosure model E2C accommodates t...

Page 41: ...e 2 Once the top cover is released from the locked position slide the cover toward the rear of the chassis 3 Lift the cover off the chassis Caution Except for short periods of time do not operate the...

Page 42: ...es which can be removed without powering down the system Only enterprise level SAS or SATA HDDs are recommended Removing Hard Drive Carriers from the Chassis 1 Press the release button on the drive tr...

Page 43: ...allation 3 Secure the drive to the carrier with four screws as illustrated above Use the four M3 flat head screws included in the HDD bag of the accessory box Note that the screws used to secure the d...

Page 44: ...hile the power is running to determine which fan requires changing Never run the server for an extended period of time with the chassis open 2 Power down the system as described in Section 4 2 and ope...

Page 45: ...4 11 Chapter 4 Chassis Setup and Maintenance Figure 4 10 Placing the System Fan...

Page 46: ...age An amber light will be illuminated on the power supply when the power is off An illuminated green light indicates that the power supply is operating Changing the Power Supply 1 Determine which pow...

Page 47: ...failed power module with the same model power supply 5 Push the new power supply module into the power bay until the tab clicks into the locked position 6 Plug the AC power cord back into the module a...

Page 48: ...nd open the chassis cover 2 Remove all cable connections to the power supply from the motherboard backplane and other components Also remove both power supply modules 3 Remove the screws securing the...

Page 49: ...board CSE PTJBOD CB3 allows the user to remotely control and monitor the chassis resources using the BMC such as powering on or off controlling fan speeds and reading temperature data from the backpl...

Page 50: ...remove the backplane from the chassis Removing the Backplane from the Chassis 1 Power down the system as described in Section 4 2 and open the chassis cover 2 Disconnect the cabling to the backplane 3...

Page 51: ...4 17 Chapter 4 Chassis Setup and Maintenance 6 Gently ease the backplane up and out of the chassis Figure 4 14 Loosening the Spring Bar Screws in the Floor of the Chassis 6...

Page 52: ...ned as directed in the previous section 3 Slide the backplane into the chassis at a slight angle pushing it up against the side of the chassis 4 Ease the backplane forward against the front of the cha...

Page 53: ...ted Avoid areas where heat electrical noise and electromagnetic fields are generated A nearby grounded power outlet is required The box your chassis was shipped in should include two sets of rail asse...

Page 54: ...more simultaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the rack be...

Page 55: ...ave on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be mai...

Page 56: ...and 36 4 deep Identifying the Sections of the Rack Rails The chassis package includes two rail assemblies Each assembly consists of three sections An inner rail that secures directly to the chassis an...

Page 57: ...ack when when the chassis is pulled out for servicing To mount the rail onto the chassis first release the inner rail from the outer rails Releasing Inner Rail from the Outer Rails 1 Pull the inner ra...

Page 58: ...he side of the chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the quick release bracket sna...

Page 59: ...r rails to the rack 4 Pull out the rear of the outer rail adjusting the length until it just fits within the posts of the rack 5 Hang the hooks of the rear section of the outer rail onto the square ho...

Page 60: ...trated above 2 Align the inner rails of the chassis with the outer rails on the rack 3 Slide the inner rails into the outer rails keeping the pressure even on both sides When the chassis has been push...

Page 61: ...permicro web site at www supermicro com for the latest updates compatible parts and supported configurations 6 2 Safety Guidelines ESD Safety Guidelines Electrostatic Discharge ESD can damage electron...

Page 62: ...5 6 1 3 1 3 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 24 13 12 1 A 1 E 3 K 7 9 R 3 2 1 1 2 3 1 2 7 8 1 2 7 8 1 2 7 8 1 2 7 8 1 2 19 20 1 5 1 5 6 9 1 2 10 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 1 7 6 12 15 17...

Page 63: ...he chassis using cable CBL NTWK 0584 or CBL NTWK 0587 8 Control Panel Connector This connector is designated JF1 and connects to the control panel on the chassis See Chapter 3 for additional control p...

Page 64: ...To enable SAS2 or SAS3 functionality on the I2 C connectors set the JP5 jumper as noted 1 2 5 6 1 3 1 3 3 2 1 4 3 2 1 4 3 2 1 4 3 2 1 4 24 13 12 1 A 1 E 3 K 7 9 R 3 2 1 1 2 3 1 2 7 8 1 2 7 8 1 2 7 8...

Page 65: ...1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 4 1 1 7 6 12 15 17 13 14 16 19 18 A C A C A E K R Y 1 5 10 20 12 13 24 25 36 37 48 MH2 MH4 JP6 U U18 U17 U16 U14 U13 JP7 JP5 JP1 JP2 JP3 JP4 JPW1 BT1 C10 Y2 U9 MH3 MH1 C...

Page 66: ...U16 U14 U13 JP7 JP5 JP1 JP2 JP3 JP4 JPW1 BT1 C10 C146 Y2 U9 MH3 MH1 J4 J6 J7 J5 U10 JF1 Q19 Q18 Q13 JPI2C1 J3 J2 U12 U11 C8 C9 FAN1 FAN2 FAN3 FAN4 FAN5 FAN6 FAN7 FAN8 FAN10 FAN9 J8 U8 Q3 Q16 R138 C14...

Page 67: ...initiates the power up sequence in three seconds After Normal Shutdown by BMC or Power Button Press the power button once The JBOD control board will initiate the power up sequence in three seconds Af...

Page 68: ...d The sticker also displays the BMC MAC address Figure 6 5 BMC Password Label IP Address The default IP address configuration mode is Dynamic Host and Configuration Protocol DHCP When connected to the...

Page 69: ...of finding the IP address 1 Identify the JBOD enclosure name for example dev sg4 2 Use the vpd command to view the IP address root hdmaster user sg_vpd p 0x85 dev sg4 Management network addresses VPD...

Page 70: ...6 10 SC216B JBOD Chassis Manual Notes...

Page 71: ...er Supply Specifications This appendix lists power supply specifications for the SC216B JBOD chassis 650W Model Supermicro Part PWS 609P 1R2 with PDB AC Input 100 240 V 4 5 11 Amp 50 60 Hz DC Output 1...

Page 72: ...SC216B JBOD Chassis Manual A 2 Notes...

Page 73: ...del consists of the BPN SAS3 216EB backplane X with the primary daughter card mounted on the right Y and a secondary daughter card mounted on the left Z Components on the front side of the BPN SAS3 21...

Page 74: ...rsonal injury and property damage carefully follow all the safety steps listed below when accessing your system or handling the components Always disconnect power cables before installing or removing...

Page 75: ...h Chip 2 Expander Chip 3 UART Connector J5 4 SDB Connector J10 5 Internal Mini SAS Connectors J9A J9B J9C J9D Figure B 2 Connectors backplane and daughter card DESIGNED IN USA BPN SAS3 216EL REV 1 00...

Page 76: ...The UART connector is designated UART and J5 It is used for manufacturer s diagnostic purposes only 4 SDB Connector The SDB connector is designated SDB and J10 It is the debug connector and is used fo...

Page 77: ...P15 S8 S14 S1 P1 P15 S14 S1 P1 P15 S14 S1 P1 P15 S14 S1 P1 P15 S1 S7 P1 P15 S8 S14 S1 S7 P1 P15 S8 S14 S1 S7 P1 P15 S8 S14 S1 P1 P15 S14 S1 P1 P15 S14 S1 P1 P15 S14 S1 P1 P15 S14 S1 P1 P15 S14 S1 P1...

Page 78: ...FAIL 5 SAS J6 ACT 6 FAIL 6 SAS J7 ACT 7 FAIL 7 SAS J8 ACT 8 FAIL 8 SAS J9 ACT 9 FAIL 9 SAS J10 ACT 10 FAIL 10 SAS J11 ACT 11 FAIL 11 SAS J12 ACT 12 FAIL 12 SAS J13 ACT 13 FAIL 13 SAS J14 ACT 14 FAIL 1...

Page 79: ...85 R17 R15 R177 L7 L5 F2 C23 CT199 CS26 C207 C135 C128 C132 C133 CB31 CB71 CB81 CB91 C131 C76 C177 C122 FAN1 J10 J5 U8 U9 U2 JP3 J11 U4 U1 SDB UART MDIO J9D J9C J9B J9A Port B Secondary Expander Ports...

Page 80: ...U15 TP62 TP15 U37 L1 F1 C176 U27 U26 R11 R184 R40 R186 R185 R17 R15 R177 L7 L5 F2 C23 CT199 CS26 C207 C135 C128 C132 C133 CB31 CB71 CB81 CB91 C131 C76 C177 C122 FAN1 J10 J5 U8 U9 U2 JP3 J11 U4 U1 SDB...

Page 81: ...or 36 pin at one end and a Mini SAS HD SFF 8643 connector at the other end It connects from the SAS2 HBA to the BPN SAS3 216EL model backplane Cable name Internal HD Mini SAS to HD Mini SAS Part CBL S...

Page 82: ...165 C96 C12 C11 C162 C108 C191 C111 C119 CB120 U15 TP62 TP15 U37 L1 F1 C176 U27 U26 R11 R184 R40 R186 R185 R17 R15 R177 L7 L5 F2 C23 CT199 CS26 C207 C135 C128 C132 C133 CB31 CB71 CB81 CB91 C131 C76 C1...

Page 83: ...O8 N8 N7 P8 P7 O7 CG5 CG4 1 2 3 A 1 E 5 H 5 1 A E H 14 13 12 11 2 24 22 12 11 22 12 11 22 12 11 4 1 1 4 1 4 1 2 9 8 1 10 1 5 10 15 20 25 30 AK AE Y R K E A J9 L8 U3 C98 C99 C102 C103 C121 C165 C96 C1...

Page 84: ...P2 MH_P3 MH_S2 MH_S3 MH4 MH3 MH2 MH1 PWR6 PWR1 PWR2 PWR3 PWR4 PWR5 OVERHEATFAIL1 12V_LED1 5V_LED1 F9 F7 F14 F13 EC25 EC26 EC27 EC28 EC9 EC8 EC7 EC6 EC5 EC4 EC3 EC24 EC23 EC22 EC21 EC20 EC2 EC19 EC18 E...

Page 85: ...L1 F1 C176 U27 U26 R11 R184 R40 R186 R185 R17 R15 R177 L7 L5 F2 C23 CT199 CS26 C207 C135 C128 C132 C133 CB31 CB71 CB81 CB91 C131 C76 C177 C122 FAN1 J10 J5 U8 U9 U2 JP3 J11 U4 U1 SDB UART MDIO J9D J9C...

Page 86: ...ter Description Internal cable connects the SAS3 backplane to external ports Cable Name 1 Meter External Mini SAS HD to External Mini SAS HD Cable Part CBL SAST 0573 Ports Single Placement External Ca...

Page 87: ...A J9 L8 U3 C98 C99 C102 C103 C121 C165 C96 C12 C11 C162 C108 C191 C111 C119 CB120 U15 TP62 TP15 U37 L1 F1 C176 U27 U26 R11 R184 R40 R186 R185 R17 R15 R177 L7 L5 F2 C23 CT199 CS26 C207 C135 C128 C132 C...

Page 88: ...R40 R186 R185 R17 R15 R177 L7 L5 F2 C23 CT199 CS26 C207 C135 C128 C132 C133 CB31 CB71 CB81 CB91 C131 C76 C177 C122 FAN1 J10 J5 U8 U9 U2 JP3 J11 U4 U1 SDB UART MDIO J9D J9C J9B J9A DESIGNED IN USA BPN...

Page 89: ...2 12 11 22 12 11 4 1 1 4 1 4 1 2 9 8 1 10 1 5 10 15 20 25 30 AK AE Y R K E A J9 L8 U3 C98 C99 C102 C103 C121 C165 C96 C12 C11 C162 C108 C191 C111 C119 CB120 U15 TP62 TP15 U37 L1 F1 C176 U27 U26 R11 R1...

Page 90: ...CB31 CB71 CB81 CB91 C131 C76 C177 C122 FAN1 J10 J5 U8 U9 U2 JP3 J11 U4 U1 SDB UART MDIO J9D J9C J9B J9A DESIGNED IN USA BPN SAS3 216EL REV 1 00 WWN ADDRESS BAR CODE A1 A2 CG1 CG2 B1 B2 C1 C2 CG3 M8 M...

Page 91: ...4 BS EN 61000 4 5 BS EN 61000 4 6 BS EN 61000 4 8 BS EN 61000 4 11 Environment 2011 65 EU RoHS Directive EC 1907 2006 REACH 2012 19 EU WEEE Directive California Proposition 65 Product Safety 2014 35...

Page 92: ...be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products...

Reviews: