Summary of Contents for AOC-ATG-b2TG

Page 1: ...User s Guide Revision 1 0a AOC ATG b2TM AOC ATG b2TG ...

Page 2: ...nia USA The State of California County of Santa Clara shall be the exclusive venue for the resolution of any such disputes Supermicro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to p...

Page 3: ...s An Important Note to the User All images and layouts shown in this user s guide are based upon the latest PCB revision available at the time of publishing The card you have received may or may not look exactly the same as the graphics shown in this user s guide Returning Merchandise for Service A receipt or copy of your invoice marked with the date of purchase is required before any warranty ser...

Page 4: ...ser s Guide Pay special attention to the following symbols for proper system installation and for safety instructions to prevent damage to the system or injury to yourself Note Additional information given for proper system setup Naming Convention for Standard Network Adapters ...

Page 5: ...t RMA supermicro com RMA Support Webmaster supermicro com Webmaster Website www supermicro com Europe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email Sales_Europe supermicro com Sales Inquiries Support_Europe supermicro Technical Support RMA_Europe supermicro RMA Support Website www supermicro nl Asia Pacifi...

Page 6: ...OC ATG b2T M G Add On Card User s Guide Asia Pacific Email Sales Asia supermicro com tw Sales Inquiries Support supermicro com tw Technical Support RMA supermicro com tw RMA Support Website www supermicro com tw ...

Page 7: ...Card Image and Layout 2 1 2 2 Major Components 2 3 2 3 LED Indicators and Connectors 2 4 2 4 Jumper Settings 2 5 2 5 Major Components of AIOM Module 2 6 Chapter 3 Installation 3 1 Static Sensitive Devices 3 1 3 2 Before Installation 3 2 3 3 Installing the Add on Card with 0 5U bracket 3 3 3 4 Installing Drivers on Windows 3 6 3 5 Installing Drivers for Broadcom BCM57416 3 7 vii Preface ...

Page 8: ... to our website at http www supermicro com products nfo networking cfm adapter 1 2 Product Highlights Advanced I O Module AIOM form factor Broadcom BCM57416 Ethernet controller Dual RJ45 Connectors PCI E 3 0 x8 interface Asset Management Features with thermal sensor Broadcom Dual Port 10Gbps Pass through Energy Efficient Ethernet IEEE STD 802 3az 2010 Broadcom TruFlow NPAR NIC Partitioning VXLAN N...

Page 9: ...RJ45 connectors Broadcom TruFlow technology Host Interface PCI E 3 0 8GT s MCTP over SMBus Function Level Rest FLR support Message Signal Interrupt MSI X Networking Features Jumbo Frames up to 9600 byte 802 3x flow control Link Aggregation 802 3ad Virtual LANs 802 1q VLAN tagging Configurable Flow Acceleration IEEE 1588 and Time Sync RDMA over Converged Ethernet RoCE ...

Page 10: ... Receive Offload LRO Receive Side Scaling RSS Transmit Side Scaling TSS NIC Partitioning NPAR 16 physical functions QoS per partition Partitioning control via sideband communication Up to 64MAC VLAN filter per partition Stateless offload configuration per partition VEB VEPA support Flow Processing Exact Wildcard Match Flow Lookup VLAN insertion deletion NAT NAPT Mirroring ...

Page 11: ... Selection ETS IEEE802 1Qau Quantized Congestion Notification QCN IEEE802 1Qau Data Center Bridging Capability eXchange DCBX IEEE802 1Qaz 8 traffic classes per port fully DCB compliant per 802 1Qbb Manageability Network Controller Sideband Interface NC SI PXE boot Asset Management with thermal sensors Power Consumption ACPI compliant power management PCI Express Active State Power Management ASPM ...

Page 12: ...al Dimensions Card PCB dimensions 76mm x 115mm W x D 1 4 Available SKUs SKUs Bracket Included Description AOC ATG b2TM BKT 0185L 2 port 10 Gigabit Ethernet adapter with a 0 5U height bracket AOC ATG b2TG BKT 0208L 2 port 10 Gigabit Ethernet Adapter with a 0 5U height narrow bracket for Grand Twin Front IO systems Note This product is only sold as part of an integrated solution with Supermicro serv...

Page 13: ...Chapter 2 Hardware Components 2 1 Chapter 2 Hardware Components 2 1 Add On Card Image and Layout AOC ATG b2TM Image AOC ATG b2TG Image ...

Page 14: ...2 2 Super AOC ATG b2T M G Add On Card User s Guide REV 1 00 AOC ATG b2TM DESIGNED IN USA JPAUX1 LAN2 LAN1 J1 Broadcom BCM4716 BAR CODE 1 1 1 3 1 2 1 4 AOC ATG b2TM and AOC ATG b2TG Layout 1 5 ...

Page 15: ...onents are on AOC ATG b2TM and AOC ATG b2TG AOC ATG b2TM and AOC ATG b2TG Major Components No Component Name Definition 1 Broadcom BCM4716 Ethernet controller 2 J1 Connector cage 3 LAN1 LAN Port 1 4 LAN2 LAN Port 2 5 JPAUX1 1 2 Enable AUX Power 3 4 Disable AUX Power Default ...

Page 16: ...ort for network connections Note To make sure that LAN port functions properly be sure to use the following cable specified by the manufacturer Direct attached twin axial copper cable or Short Range or Long Range fiber optic cable used in conjunction with optional optical transceiver LAN LED Each LAN port connector has two LEDs at the bottom of the PCB See the table below for more information Port...

Page 17: ...s NOT in standby mode IPMI Support FailOver Support WoL Support Yes Yes N A AOC JPAUX1 set to Enabled When system MB goes into standby mode IPMI Support FailOver Support WoL Support Yes Yes Yes When system MB is NOT in standby mode IPMI Support FailOver Support WoL Support Yes Yes N A JPAUX1 for Standby Power Function Definition Disable No standby power to AOC NIC Disable jumper to disconnect the ...

Page 18: ...racket Before a computer system can operate all slots are required to be populated If an AIOM module is used be sure that the bracket is firmly installed into the chassis This will ensure that the card that is installed to the bracket is seated securely in the motherboard connector For instructions on how to install and uninstall an AIOM module please refer to chapter 3 ...

Page 19: ...c bag Handle the add on card by its edges only do not touch its components Put the add on card back into the antistatic bags when not in use For grounding purposes make sure that your system chassis provides excel lent conductivity between the power supply the case the mounting fasteners and the add on card Unpacking The add on card is shipped in antistatic packaging to avoid static damage When un...

Page 20: ...r down the system 2 Unplug the power cord 3 Use industry standard anti static equipment such as gloves or a wrist strap and follow the precautions on page 3 1 to avoid damage caused by ESD 4 Familiarize yourself with the server motherboard and or chassis documenta tion 5 Confirm that your operating system includes the latest updates and hotfixes ...

Page 21: ...to a fixed structure it is recommended to remove the system top cover for ease of installation A Uninstalling an AIOM module 1 Unscrew the blue knob from the system 2 Pull on the tab and knob evenly on both sides of the card to disengage the AIOM module from the motherboard connector 3 Gently slide the AIOM module out Remove the AIOM card from this slot The AIOM card with the 0 5U bracket installe...

Page 22: ...sh onto the metal bracket The AIOM module should slide into the chassis until the card is securely seated in the connector 3 Press the blue knob 4 Turn the knob clockwise to secure module onto the chassis Remove the AIOM card from this slot The AIOM card with the 0 5U bracket installed Screw knob to engage disengage Pull tab to engage disengage ...

Page 23: ... an AIOM module An AIOM slot with an AIOM slot cover 1 Remove the AIOM slot cover by unscrewing the knob and screw that attaches the bracket to the chassis 2 Pull the bracket away and set it aside 3 Position the AIOM module in front of the empty slot 4 Gently push onto the metal bracket The AIOM module should slide into the chassis until the card is securely seated in the connector 5 Turn the knob...

Page 24: ... the prompts to complete the installation 3 4 Installing Drivers on Windows Follow the steps below to install the drivers for the Windows operating systems Download the drivers from Intel Download Center or the Supermicro site at https www supermicro com wftp Networking_Drivers 1 Run CDR NIC 2 When the SUPERMICRO window appears click on the computer icon next to the product model ...

Page 25: ...l the following yum y install libibverbs infiniband diags perftest qperf librdmacm utils yum y install groupinstall InfiniBand Support 2 From the CDR NIC LAN driver CD or FTP site go to the following directory Broadcom 10G Linux_Driver 3 Download the Linux driver package file netxtreme bnxt_en ver tar gz 4 Install the driver by entering the following commands tar xzvf nextreme bnxt_en ver tar gz c...

Page 26: ...s d echo usr local lib etc ld so conf ldconfig v Windows Drivers Use the following procedures to install drivers on the Windows operating system Installing 10G Drivers for the Windows Operating System 1 From the CDR NIC LAN driver CD or FTP site go to the following directory Broadcom 10G Windows 2 Choose the desired Windows driver package folder 3 Drivers are in inf format You can install the driv...

Page 27: ... expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro disclaims any and all liability and should buyer use or sell such products for use in such ultra hazardous ap plications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions...