PS Current Threshold1
The PS Current Threshold1 is defi ned in 1/4A (Amperes) increments and uses the BIOS
mailbox command 0x3. A value of 400 equals 100A. Range is 0-512 which translates to
0-128A. Enter 0 for AUTO. Default is 80 for 20A.
PS Current Threshold2
The PS Current Threshold2 is defi ned in 1/4A (Amperes) increments and uses the BIOS
mailbox command 0x3. A value of 400 equals 100A. Range is 0-512 which translates to
0-128A. Enter 0 for AUTO. Default is 20 for 5A.
PS Current Threshold3
The PS Current Threshold2 is defi ned in 1/4A (Amperes) increments and uses the BIOS
mailbox command 0x3. A value of 400 equals 100A. Range is 0-512 which translates to
0-128A. Enter 0 for AUTO. Default is 20 for 5A.
PS3 Enable
Enable or Disables PS3. Uses BIOS VR mailbox command line 0x3. The options are Enabled
and Disabled.
PS4 Enable
Enable or Disables PS4. Uses BIOS VR mailbox command line 0x3. The options are Enabled
and Disabled.
IMON Slope
IMON (Load Current Monitor) Slope is defi ned in 1/100 increments and uses the BIOS VR
mailbox command 0x4. Range is 0-200. For example, enter 125 for a 1.25 slope. Enter 0
for AUTO.
IMON Offset
IMON Offset is defi ned in 1/1000 increments and uses the BIOS VR mailbox command 0x4.
For example, enter 25,348 for a 25.348 offset. Range is 0-63999.
IMON Prefi x
This feature sets the IMON offset value to a positive or negative number. The options are +
and -.
VR Current Limit
This feature sets the Voltage Regulator current limit. The value represents the maximum
instantaneous current allowed at any given time. The value is represented in 1/4A (Ampere)
increments. A value of 400 equals 100A. Set this number to 0 for Auto. This uses the BIOS
VR mailbox command 0x6.