SUPERSERVER 5018D-FN4T User's Manual
6-10
Replacing the Power Supply
5. If power is on, power down as described in Section 6-2. Remove the chassis
cover.
6. Disconnect all wiring from the power supply.
7. Remove the four screws which hold the power supply in the chassis. Two
mounting screws are located on the rear of the power supply. Two bottom
mounting screws are accessed on the underside of the chassis and extend
upwards through the mounting holes to hold the power supply in place. Set the
screws aside for later use.
8. Remove the power supply from the chassis.
9. Align the mounting thru holes on the new power supply with the mounting holes
in the chassis and reattach the power supply to the chassis using the four screws
which were previously set aside.
10. Reconnect the wiring and the power cord to the power supply, replace the cover
and power up the server.
Figure 6-11. Installing the Power Supply
Power Supply
Mounting Thru Holes
Rear Mounting
Screws
Insert Bottom
Mounting Screws
from Underside