2
object during an Open or Close Cycle, serious personal injury, death and/or property/product damage may occur
Right hand installation shown (inside garage looking out) Fig. 1
Check that there is sufficient side clearance to fit the operator unit. It may be fitted to either the
right or left hand side. (fig. 1)
Minimum side clearance:
The minimum side clearance between door
curtain and the inside edge of mounting
bracket is 85mm;
The minimum side clearance between door
curtain and the outside edge of mounting
bracket is 135mm. (fig. 2)
FIXING OF DOOR CURTAIN TO DRUM
WHEEL
The door curtain must be secured to the drum wheel
with suitable fasteners.
With the door in the fully closed position, mark
the curtain at points (A) and (B)
CHECK OPERATION OF THE DOOR
Before beginning the installation of the Opener, check
the operation of the door. The door must be well
balanced and operate smoothly and freely. When
opened to between 900~1200mm from the floor and
released, the door should remain in one fixed position
and not rise or fall. The door should not bind or stick in
the guide tracks. The ideal operational effort, required
to open or close the door, should not exceed a force of
10kg.
Superlift does not recommend the
installation of an Automatic Opener to a badly
worn or damaged door.
INSTALLATION INSTRUCTIONS
Fig. 2
Fig. 3