VENTING INSTALLATION

Continued

Pitch

Slope Opening 

"A" Max.

Used Flashing

Model No. 

Flat

19.5"

V6F-10DM

0-6/12

26.6°

22'

V6F-10DM

6/12-12/12

45.0°

27"

V12F-10DM

5.  Add  next  sections  of  pipe  until  end 

penetrates  roof  line.  Check  to  see  that 

proper clearances are maintained. Extend 

chimney by adding sections of double wall 

pipe until pipe is minimum of 30" above 

highest point of roof cutout. Termination 

and chimney must extend a minimum of 

36" above highest point where it passes 

through roof.

19.5" Min.

30" Min.

2" Min.

2" Min.

2" Min.

Opening "A"

Figure 14 - Roof Opening Measurements

Nail Only 

Outer 

Perimeter 

of Flashing

Storm Collar

Flashing

Cone

Underlap Shingles 

at Bottom

Overlap 

Shingles Top 

and Sides Only

Figure 15 - Flashing Installation

FLASHING INSTALLATION (V6F-10DM 

OR V12F-10DM)

Determine the flashing to be used with the 

roof opening chart. Slide flashing over pipe 

until  base  is  flat  against  roof.  Replace  as 

many shingles as needed to cover exposed 

area and flashing base. Secure in position by 

nailing through shingles (see Figure 15). DO 

NOT NAIL THROUGH FLASHING CONE.

Storm Collar Installation (SC2-1)

Place storm collar over pipe and slide down 

until it is snug against the open edge of the 

flashing  (see  Figure  16). Apply  waterproof 

caulk around the perimeter of the collar to 

provide a proper seal.

Figure 16 - Storm Collar

Chimney 

Pipe

Waterproof 

Caulk

Storm 

Collar

Flashing

Installing Flashing on a Metal Roof

When installing the flashing on a metal roof, 

it is required that putty tape be used between 

the flashing and the roof. The flashing must be 

secured to the roof using #8 x 3/4" screws and 

then sealed with roof coating to prevent leak-

age through the screw holes. A roof coating 

must also be applied around the perimeter of 

the flashing to provide a proper seal.

Summary of Contents for WRT4842RH

Page 1: ...ome USA only or mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other g...

Page 2: ...ireplace read these instructions through completely This INNOVATIVE HEARTH PRODUCTS fireplace and its components are safe when installed according to this installation manual Unless you use IHP compon...

Page 3: ...O COMBUSTIBLE MATERIAL ON FACE MINIMUM 18 TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 66 X 20 2 CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL 42 23 1 2 25 1 8 22 3 4 30 1 2 29 4 3 8 15 3 4 5 8 17...

Page 4: ...MATERIAL COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE 0 TO BOTTOM OUTSIDE AIR 11 2 AIR SPACE BACK AND SIDES GAS LINE KNOCKOUTS 12 EACH SIDE MINIMUM 18 TO PERPENDICULAR SIDEWALL HEARTH EXTENS...

Page 5: ...into consideration the following guidelines 1 The location must allow for proper clear ances see Figures 5 and 6 2 Consider a location where fireplace will not be affected by drafts air conditioning...

Page 6: ...igure 5 WARNING Hearthextension is to be installed only as shown in Figure 4 MANTELS Amantel may be installed if desired see Figure 6 Woodwork such as wood trims mantels or any other combustible mater...

Page 7: ...ons Figure 7 Outside Air Kit Secure to Collars with Metal Tape Screws or Straps Min of 1 4 x 20 in size Air Inlet Location Must Allow For Bushes or Snow Vent Hood Required for Wall Installation Air In...

Page 8: ...outer pipe sections are locked to gether When installing double wall snap lock chimney together it is important to assure the joint between the chimney sections is locked Check by pulling chimney upwa...

Page 9: ...ing Figure 13 Firestop Spacer with Attic Space Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 PENETRATING ROOF To maintain a...

Page 10: ...OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover exposed area and flashi...

Page 11: ...n 10 2 Min 10 3 Min 2 Min 3 Min Level of Flue Gas Outlet Figure 19 18 Foot Rule Terminations Spark Arrestor The fireplace system must be terminated with the listed round top or chase terminations In a...

Page 12: ...ry They should be positioned a distance apart as shown in Figure 20 4 Install rear refractory panel This panel has a top and bottom To determine which is which match up the pattern on the rear panel w...

Page 13: ...d pull out insula tion from gas line conduit sleeve Save insulation for reuse Replace screws 3 Run a 1 2 black iron gas line into fireplace through the rear at gas line conduit sleeve if usingaraisedp...

Page 14: ...urning Fireplaces ANS Z21 60 or Z21 84 and shall also be installed in accordance with the National Fuel Gas Code ANSI 7223NFPA 54 latest edition If you wish to install an unvented vent free gas log se...

Page 15: ...al posi tion making sure top pins slide into door track Door is installed when top door pin snaps into spring clip 2 Repeat step 1 for remaining door If you find doors do not close properly or do not...

Page 16: ...place and glass door retain their beauty and function properly Both the flue damper and glass doors mustbefullyopenedbeforestartingfire Thiswill provide sufficient combustion air and maintain safe tem...

Page 17: ...ARTH PROD UCTS Homeowner s Guide included with your fireplace for proper fire building technique and ash removal procedures These fueling guide lines must be followed in order to achieve maximum emiss...

Page 18: ...ified models are cleaner and pollute less than those models that have not met this emissions level Exposure to smoke has been associated with respiratory illness and other health problems Models that...

Page 19: ...EPLACEMENT PARTS If this product is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace part...

Page 20: ...www SuperiorFireplaces US com 126604 01A 20 PARTS 42 AND 50 MODELS 1 21 20 5 6 7 10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 26 27 28 29 30...

Page 21: ...1 19 123298 02 Ash Box Assembly 1 20 Inner Dome Assembly 1 21 Smoke Shield 1 22 Damper Control Bracket 1 23 109457 02 Screen 42 2 109457 01 Screen 50 2 117556 02 Screen 42 Stainless 2 117556 01 Scree...

Page 22: ...www SuperiorFireplaces US com 126604 01A 22 PARTS MODELS 42 AND 50 Picture may vary from actual 1 2 5 3 4 6 6...

Page 23: ...125833 01 Left Stacked 42 Natural White 1 125836 02 Left Herringbone 42 Red 1 125836 01 Left Herringbone 42 Natural White 1 125839 02 Left Stacked 50 Red 1 125839 01 Left Stacked 50 Natural White 1 1...

Page 24: ...tinum BDG42B 42 Brushed Brass BD50 50 Black BD50P 50 Platinum BD50B 50 Brushed Brass DOUBLE WALL PIPE 12 12DM 18 12DM 24 12DM 36 12DM 48 12DM 12 12HT 18 12HT 24 12HT 36 12HT and 48 12HT 30 OFFSET AND...

Page 25: ...0 to 6 12 Pitch V12F 10DM 6 12 to 12 12 Pitch ACCESSORIES Continued SQUARE CHASE TOP TERMINATION STL 12D AND STL 12DMP BLACK ROUND TOP TERMINATIONS RLT 12D AND RLT 12HT STORM COLLAR SC2 1 FIRESTOP SP...

Page 26: ...cannot ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance...

Page 27: ...rmal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning...

Page 28: ...IS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ________________...

Page 29: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 30: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 31: ...___________________________________ ______________________________________________________ ______________________________________________________ ______________________________________________________...

Page 32: ...126604 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126604 01...

Reviews: