Superior WRT3820WS Installation And Operation Instructions Manual Download Page 25

25

Printed in U.S.A. © 2013  Innovative Hearth Products LLC

P/N 900224-00, Rev. NC  12/2013

Innovative Hearth Products

1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210

Innovative Hearth Products

Superior™ Brand Wood-Burning Fireplace

20 Year Limited Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your Superior™ Brand wood burning fireplace ("Product") to be free from defects in materials and 

workmanship at the time of manufacture. The Product body, firebox and ceramic glass carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited War-

ranty against thermal breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the 20 

Year Limited Warranty period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair 

or replacement is not commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also 

pay IHP prevailing labor rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to five years. THERE ARE EXCLUSIONS AND 

LIMITATIONS to this 20 Year Limited Warranty as described herein.

COVERAGE COMMENCEMENT DATE

Warranty coverage begins on the date of installation. In the case of new home construction, warranty coverage begins on the date of first occupancy of the dwelling or six 

months after the sale of the Product by an independent IHP dealer/distributor, whichever occurs earlier. The warranty shall commence no later than 24 months following the 

date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This 20 Year Limited Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 

instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.
This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 

provided. The Product body and firebox carry the 20 Year Limited Warranty from the date of installation. Vent components, trim components, paint and applied stains are 

excluded from this 20 Year Limited Warranty. The following do not carry a 20 Year Limited Warranty but are warranted as follows:

Air tubes, baffles and brick retainers 

– Repair or replacement for one year from the date of installation

Cast iron parts

 – Replacement for one year from date of installation

Catalyst

 – Carries a separate warranty. Refer to the warranty certificate provided for that part

Electrical components

 – Repair or replacement for one year from the date of installation

Fireplace screens, refractory and side shields (metal or refractory)

 – Repair or replacement for two years from date of installation. Excludes hairline cracks.

Fuel grates

 –These parts are considered consumable accessories and therefore are not warranted, with the exception of defects in material or workmanship which 

are covered for 90 days from the date of installation

Gaskets

 – Replacement for one year from date of installation

Gold & nickel plating – Replacement for two years from date of installation. Excludes tarnishing

Optional glass doors 

– Repair or replacement for 90 days from the date of installation

Refractory & screens 

– Replacement for two years from date of installation. Excludes hairline cracks

Removable air tubes

 – Repair or replacement for seven years from date of installation. IHP prevailing labor rates for years one through five.

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component.

Parts not otherwise listed carry a 90 day warranty from the date of installation.
Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fire, flood or acts of God; (b) damages caused by abuse, negligence, misuse, or 

unauthorized alteration or repair of the Product affecting its stability or performance. (The Product must be subject to normal use with approved fuels listed in the Operation 

Manual provided with the product. This includes burning such fireplace fuels as wood and natural or propane gas. Fuel products with abnormal burning characteristics, 

including but not limited to fuel such as driftwood, coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the 

Product or may cause it to function improperly.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with 

the Product; (d) damages, repairs or inefficiency resulting from faulty installation or application of the Product.
Coverage of this 20 Year Limited Warranty is conditional upon use of an adequate fuel grate on factory-built fireplaces only, when applicable.

IHP is not responsible for inadequate fireplace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction condi-

tions which may generate negative air pressure in the room in which the appliance is installed. Additionally IHP assumes no responsibility for smoking conditions caused by 

inadequate chimney height, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions. Certain IHP Products are listed for use with 

Security Chimneys International, Ltd. or IHP chimney systems only. Use of chimney components other than that specified in the Product manual will void the Product warranty.
This 20 Year Limited Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction which are 

not manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due 

to any malfunction or defect in equipment are not covered by this 20 Year Limited Warranty. All replacement or repair components will be shipped F.O.B. from the nearest 

stocking IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 

or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified herein.
In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 

replacement or repair, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fitness for a particular 

use or purpose, and there is no implied condition of fitness for a particular use or purpose.
IHP makes no expressed warranties except as stated in this 20 Year Limited Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty.
No one is authorized to change this 20 Year Limited Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 

do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this 20 Year 

Limited Warranty are in addition to and not a modification of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this 20 Year Limited Warranty and to  decide, in its sole discretion, upon the method of settlement.
To receive the benefits and advantages described in this 20 Year Limited Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP.

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors.

 IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without first obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/

distributor, then you must notify IHP in writing. IHP must be notified of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 

IHP Warranty Department at 1508 Elm Hill Pike, Suite 108; Nashville, TN 37210 or visit our website at WWW.SUPERIORFIREPLACES.US.COM.

Summary of Contents for WRT3820WS

Page 1: ...ances Anymodificationoralterationofthefireplacesystem including but not limited to the fireplace chimney components and accessories may void the warranty listings and approvals of this system and coul...

Page 2: ...own in front ofanopenflamewhenthewindow is opened Keep any combustible furniture materials or decorative pillows at least 48 1219 mm from the front fireplace opening WARNING Never leave your fireplace...

Page 3: ...imney Model ASHT S 2100 HT6000 HT6103 or AC manufactured by Security Chimneys Inter national only OR 7 diameter chimney Model ASHT and HT6103manufacturedbySecurityChimneys International only 6 and 7 C...

Page 4: ...WRT3820WS fireplace will operate best if attention is given to operating the unit with the damper fully opened after refueling in order to bring the firebox and the chimney system up to their optimum...

Page 5: ...ense in the relatively cool chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire The chimney shall be...

Page 6: ...slight amount of friction The door gasket does not need to be tight in all areas since a small amount of leakage is not hazardous or detrimental to the performance of your fireplace Figure 5 Door Ins...

Page 7: ...et dirty unless the fuel firebox and glass are maintained at hot temperatures see Refueling For Best Performance To clean the glass there are a numberofspeciallydesignedcleaners YourIHP dealercanrecom...

Page 8: ...e entire width of the fireplace The combustible floor in front of the fireplace must be covered with at least a 1 2 inch of non combustible material tile marble stone etc See Figure 7B Cold climate IN...

Page 9: ...65 mm 31 11 16 805 mm 37 5 8 956 mm 10 254 mm 10 15 16 278 mm OUTSIDE CHASE G C A Back Wall of Chase Enclosure Including Finishing Materials if any Rough Framing Face Unfinished Shown Zero Clearance F...

Page 10: ...in 51mm x 76mm Spacer Mantel and Facing Side View 2 Rock Board or Other Noncombustible Facing Drywall Insulate Joists Same As Ceiling Draft Stops Firestop CTDT Termination Note Non Combustible Chase F...

Page 11: ...tible mate rial should be superposed or projecting over the front of the fireplace Noncombustible Facing Drywall 2 X 3 Min Rock Board or Other Spacer Figure 12 13 x 13 10 3 1m Max Figure 13 Maintain a...

Page 12: ...m to ceiling uCombustibles are not allowed below top spacers above the fireplace Facing in front of fireplace must be non combustible below this area u 12 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE...

Page 13: ...e door closed it will pull only a slight amount of air from the house Nevertheless the outside air kit might be mandatory in your jurisdiction check your local building code To install an outside air...

Page 14: ...are especially prone to flow reversal 2 The IHP fireplace model WRT3820WS may be installed only with Security Chimneys International Ltd 6 diameter chimney systems The WRT3820WS fireplace may also be...

Page 15: ...between the roof and the flashing with roofing pitch see Figures 26 and 27 For sloping roofs place the flashing under the upper shingles and on top of the lower shingles Nail the flashing to the roof...

Page 16: ...line up the center of the hole Cut a hole for the chimney in the ceiling floor Frame this hole as described previously refer to section Chimney Instal lation Instructions 5 From below install a firest...

Page 17: ...22 mm 6 1 8 156 mm 11 280 mm 14 1 8 359 mm 16 7 8 429 mm 18 7 16 468 mm 23 584 mm 26 3 16 665 mm B 27 11 16 703 mm 33 1 2 851 mm 50 7 8 1292 mm 62 1 2 1588 mm 72 5 8 1845 mm 78 7 16 1992 mm 95 3 4 243...

Page 18: ...d that you use the insulated wall radiation shield since it will maintain the home s thermal barrier RSM and RSMI30 RSMI45 Canada Only Chimney Model Angle Hole Size ASHT HT6103 6 dia Canada only 30 28...

Page 19: ...provided with the support CHIMNEY MODEL MAXIMUM HEIGHT OF SUPPORTED CHIMNEY Offset Support Roof Support ASHT HT6103 6 dia 28feet 8 54m 29feet 8 84 m S 2100 HT6000 6 dia 18feet 5 49m 20feet 6 1 m AC 6...

Page 20: ...nry chimney 2 In the middle of the oval drill a hole in the masonry chimney at 45 3 Increase the size of the hole until a 45 Tubinox liner elbow can be easily slipped through 4 Slide the liner down fr...

Page 21: ...o disk VTU fan to flexible pipe adapter BISAVF back draft damper BISBD aluminium tape BISFWK 1 BISFWK 1 Flexible pipe 5 I D x 15 ft Long 5FLEX15 5FLEX15 Flexible pipe 5 I D x 30 ft Long 5FLEX25 5FLEX2...

Page 22: ...ory PR SR2827 Front refractory 2 pieces PR SR2829 Secondary air tube back PR SR2906 Secondary air tube middle or front PR SR2830 Tube lock 2 pieces PR SR2873 Fireplace left side PR SR2848 Fireplace ri...

Page 23: ...is needed immediately off the top of the fireplace an elbow starter section AC6SB30 is available oChimney Adaptor 7in If you want to install a 7in ASHT HT6103 chimney an adaptor is available 6AW7 Secu...

Page 24: ...nsulated Wall Radiation Shield 6 12 6LRSMI 6LRSMI Adaptors to Masonry Chimney Masonry Chimney Adaptor 45 BISUMA for use with Tubinox liner CANADA ONLY BISUMA Masonry Chimney Adaptor 30 BISUMA30 for us...

Page 25: ...normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burnin...

Page 26: ...age 22 for a complete replacement parts list Use only parts sup plied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevail...

Reviews: