background image

Superiorfireplaces.US.com

127017-01B

14

Figure 21 - Installing Grate Retainers

Figure 23 - Installing Fireplace Screen

Rating Plate

Hole for Screen Rod

Leading 

Bricks

 WARNING

LIFTING HAZARD

SINGLE -PERSON LIFT COULD 

CAUSE INJURY.

USE ASSISTANCE WHEN MOVING 

OR LIFTING.

REFRACTORY PANEL INSTALLATION

IMPORTANT: Installation of Refractory panels should 

be done after the fireplace is placed in a permanent 

location.

1.  Remove grate, screen assemblies and all hardware components 

out of the firebox. The bottom panel is preinstalled in the firebox. 

Make sure the bottom refractory panels is centered in the firebox 

and flush with the front of the fireplace. 

2.  Place cardboard on top of bottom refractory panel as a protection 

to prevent shipping and scratching during installation of the other 

panels.

3.  Position "Z" shaped grate retaining brackets on top of the notched 

area toward the rear of the bottom refractory. They should be 

positioned a distance apart as shown in Figure 21. 

4.  Install rear refractory panel. This panel has a top and bottom. To 

determine which is which, match up the pattern on the rear panel 

with the left and right sides before installing the rear panel. Make 

sure panel is center before continuing.  

5.  Install the right and left refractory panels with the gas line knock

-

outs orientated down toward the bottom refractory. Align the left 

and right panels with the rear panel so the grout lines line up. 

6.  Install the upper corner brackets and tighten set screws (Figure 

22).

7.  Install grate by placing rear legs into slots in the grate retainers 

(Figure 22).

 WARNING: Risk of fire! Replace grate with IN-

NOVATIVE HEARTH PRODUCTS grate only (see Parts, 

page 23). This grate has been designed to keep the 

operation of your fireplace safe and efficient.

INSTALLING SCREEN

1.  Slide round end of screen rod into rings at top of screen. Attach one 

push-on nut to end of rod before attaching last ring of screen.

2.  Insert the round end screen rod into hole on the  left and right side 

of smoke shelf (Figure 23).

3.  Mount flat end of screen rod with #10 x 5/8" to center of smoke 

shelf.

4.  Install other screen rod in same manner.

Figure 22 - Installing Refractory Panels

LEFT BRICK

PANEL

PANEL

RIGHT BRICK

REAR BRICK

PANEL

BOTTOM

BRICK PANEL

GRATE

GRATE RETAINER

ASH PANEL

BRACKET (2x)

UPPER CORNER

BRACKET (2x)

Summary of Contents for WRE4536RH

Page 1: ...e with a vent free gas log heater approved to ANSI Z21 11 2 standard FOR CANADA The authority having jurisdiction such as the municipal building department fire department etc should be contacted befo...

Page 2: ...e or use gasoline or any other flammable vapors or liquids in the vicinity of this or any other appliance Due to high temperatures the appliance should be located out of traffic and away from furnitur...

Page 3: ...insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNINGIMPROPERFUEL I E CHAR COAL CAN RESULT IN CARBON MONOXIDE POISON ING WHICH MAY LEAD TO DEATH Carbon Monoxide Poison...

Page 4: ...BOARD NO COMBUSTIBLE MATERIAL ON FACE MINIMUM 12 TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 74 X 20 1 CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL OUTSIDE AIR 36 21 1 2 20 29 14 1 2 22 1 2 26 5...

Page 5: ...KOUTS 12 EACH SIDE COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE MINIMUM 18 TO PERPENDICULAR SIDEWALL HEARTH EXTENSION 66 X 20 2 CHIMNEY AIRSPACE CLEARANCE TO COMBUSTIBLE MATERIAL 42 23 1 2 2...

Page 6: ...TERIAL COMBUSTIBLE WALL BOARD NO COMBUSTIBLE MATERIAL ON FACE 0 TO BOTTOM OUTSIDE AIR 11 2 AIR SPACE BACK AND SIDES GAS LINE KNOCKOUTS 12 EACH SIDE MINIMUM 18 TO PERPENDICULAR SIDEWALL HEARTH EXTENSIO...

Page 7: ...outlet of termination is 9 5 feet minimum of 4 feet of chimney pipe sections required for outdoor installation FRAMING 1 Frame opening for fireplace using dimensions shown in Figures 4 and 5 2 If fire...

Page 8: ...6 Hearth Extension Seal Gap Fireplace Front Ember Protector Fireplace Front Raised Hearth Fireplace Front Elevated Ember Protector Ember Protector Seal Gap Hearth Extension MANTELS A mantel may be in...

Page 9: ...T Pipe Section 34 5 8 48 12DM 48 12HT Pipe Section 46 5 8 RLT 12D RLT 12HT Round Termina tion 7 3 4 STL 12D Square Chase Top with Slip Section 7 to 15 The lineal gain for the terminations is measured...

Page 10: ...combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart and Figure 10 2 Chimney weight above offset rests on return elbow Straps must be securely nailed to rafters or joists see...

Page 11: ...e Above Ceiling Existing Ceiling Frame Firestop Spacer Screws or Staples Min of 8 Firestop Spacer Screws or Staples Min of 8 Existing Ceiling Frame IMPORTANT NOTICE When penetrating a ceiling into an...

Page 12: ...ALLATION V6F 10DM OR V12F 10DM Determine the flashing to be used with the roof opening chart Slide flashing over pipe until base is flat against roof Replace as many shingles as needed to cover expose...

Page 13: ...be sure to provide adequate distance between terminations to prevent smoke spillage from one termination to another We suggest that terminations be separated at least 24 center to center and stacked...

Page 14: ...ine which is which match up the pattern on the rear panel with the left and right sides before installing the rear panel Make sure panel is center before continuing 5 Install the right and left refrac...

Page 15: ...ATION Figure 24 Gas Line Access Side Firebrick Finished Side Brick with Access Hole Outside of Fireplace Gas Line Conduit Insulation Gas Conduit Cover 1 2 Dowel Remove Knockout Gas line hook up should...

Page 16: ...doors completely folded insert bottom pivot pin into pivot hole located near bottom corner of front face opening and swing door to vertical position making sure top pins slide into door track Door is...

Page 17: ...ullyopenedbeforestartingfire Thiswillprovidesufficientcombustion air and maintain safe temperatures in firebox IMPORTANT The glass must be allowed to warm slowly and evenly The tempered glass will wit...

Page 18: ...10 9 11 12 13 16 17 15 14 8 24 23 3 25 18 2 22 19 4 MODEL CATALOG NO WRE4536RS F0437 WRE4536WS F0438 WRE4536RH F0439 WRE4536WH F0440 WRE4542RS F0441 WRE4542WS F0442 WRE4542RH F0443 WRE4542WH F0444 WRE...

Page 19: ...EPLACE TOP ASSEMBLY 50 1 10 J6997 SPACER FIREPLACE TOP 42MC 4 11 FIREPLACE SURROUND ASSEMBLY 1 12 J4362 SPACER CLEARANCE 36 42 50 6 13 J5329 BRACKET F P HANDLE 4 14 J6900 PLATE OUTSDE AIR COVER 36E44...

Page 20: ...ent location WARNING LIFTING HAZARD SINGLE PERSON LIFT COULD CAUSE INJURY USE ASSISTANCE WHEN MOVING OR LIFTING PARTS 1 2 5 3 4 6 6 MODEL CATALOG NO WRE4536RS F0437 WRE4536WS F0438 WRE4536RH F0439 WRE...

Page 21: ...R RED 1 J6609 REFRACTORY RT 42 STK RED 1 J6615 REFRACTORY RT 42 HER RED 1 J6621 REFRACTORY RT 50 STK RED 1 J6627 REFRACTORY RT 50 HER RED 1 3 J5093 REFRACTORY LEFT 36 STK RED 1 J5101 REFRACTORY LEFT 3...

Page 22: ...EFRACTORY RT 42 STK WHITE 1 J6614 REFRACTORY RT 42 HER WHITE 1 J6620 REFRACTORY RT 50 STK WHITE 1 J6626 REFRACTORY RT 50 HER WHITE 1 3 J5092 REFRACTORY LEFT 36 STK WHITE 1 J5100 REFRACTORY LEFT 36 HER...

Page 23: ...2DM 36 Section Double Wall Pipe Snap Lock F0936 48 12DM 48 Section Double Wall Pipe Snap Lock F0953 12 12HT 12 Section Hi Temp Double Wall Pipe Snap Lock F0954 18 12HT 18 Section Hi Temp Double Wall P...

Page 24: ...F0947 RLT 12D Round Top Termination with Louvered Screen F0960 RLT 12HT Hi Temp Round Top Termination with Louvered Screen FIRESTOP THIMBLE F0944 FST10 Firestop Thimble LABEL UL127 50PK WARNING HOT Fi...

Page 25: ...Chimney Support F0960 RLT 12HT Round Top w Louvers F0961 AP 12HT Anchor Plate Collar Assembly Masonry Fireplaces F0951 CAK 12 Cold Air Collar Kit When ordered alone this part cannot ship via parcel d...

Page 26: ...upplied from the manufacturer Normally all parts should be ordered through your IHP distributor or dealer Parts will be shipped at prevailing prices at time of order When ordering repair parts always...

Page 27: ...e subject to normal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with ab...

Page 28: ...lso to discontinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2014 IHP LLC P N 127017 01 Rev B 10 2015 P127017 01 1508 Elm Hill Pike Suit...

Reviews: