Superior WRE3836RH Installation And Operation Instructions Manual Download Page 14

www.SuperiorFireplaces.US.com

127023-01A

14

OPTIONAL GAS LINE INSTALLATION

Figure 21 - Gas Line Knockout

Side 

Firebrick 

Finished 

Side

Refractory 

Knockout 

Plug

Outside of 

Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Gas  line  hook  up  should  be  done  by  your 

supplier or a qualified service person.

Note: Before you proceed, make sure your 

gas supply is turned off.

Use only a 1/2" black iron pipe and appropri

-

ate fittings. 
1.  Remove knockout indentation on refracto

-

ry or firebrick wall located above refractory 

hearth  floor.  Knockout  indentation  must 

be  firmly  tapped  with  any  solid  object, 

such as a 1/2" dowel, until it is released. 

Remove fragmented portions of refractory 

(see Figure 21).

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas 

Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough Threaded 

End for Fitting Connection

Figure 22 - Gas Line Installation

2.  Remove gas line cover plate located on 

either side of fireplace and pull out insu

-

lation from gas line conduit sleeve. Save 

insulation for reuse.

 

Note: Secure incoming gas line to wood 

framing to provide rigidity for threaded end.

4.  Repack insulation around gas line and into 

sleeve opening. Seal any gaps between 

gas line and refractory knockout hole with 

refractory cement or commercial furnace 

cement. Install gas appliance or cap off 

gas line if desired.

PUREFIRE HOOD INSTALLATION

1.  The PureFire hood supplied with this fire

-

place is packaged in a separate box and 

placed in the firebox during shipping.

2.  Remove hood from box. 

3.  Lift the hood up into the fireplace at an 

angle  with  the  rear  facing  up.  Set  the 

front section of the hood on the refractory 

brackets. Then tilt the rear toward the back 

of the fireplace so the hood is resting on 

refractory brackets (see Figure 20). The 

rear of the hood will be touching the rear 

of the fireplace.

Figure 20 - Installing PureFire Hood

Hood

Refractory

 

Retainer

3.  Run a 1/2" black iron gas line into fireplace 

through rear at gas line conduit sleeve (if 

using a raised platform, add height). Provide 

sufficient gas line into fireplace chamber for 

fitting connection (see Figure 22).

Summary of Contents for WRE3836RH

Page 1: ...bile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used WARNING If the information in these instructions is not followed exactly a fire or explosion may result causing property damage personal injury or death AVERTISSEMENT Assurez vous de...

Page 2: ...ALYTIC FIREPLACE OWNER S OPERATION AND INSTALLATION MANUAL PFS US C This fireplace is approved for use as a wood burning fire place or for use with a vented gas log approved to ANS Z21 60 and Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard A INNOVA TIVE HEARTH PRODUCTS hood must be installed when using a vent free log heater see Accessories page 21 Thi...

Page 3: ...ocal distributor IMPORTANT Check local codes before installing this fireplace Before beginning installation of this fireplace read these instructions through completely This INNOVATIVE HEARTH PRODUCTS fireplace and its components are safe when installed according to this installation manual Unless you use IHP components which have been designed and tested for the fireplace system you may cause a f...

Page 4: ... TOP SPACERS NO COMBUSTIBLE MATERIAL ON FACE GAS LINE KNOCK OUTS AIR KIT KNOCK OUT GAS LINE KNOCK OUTS ELECTRICAL OUTLET LEFT SIDE RIGHT SIDE 9 125 11 435 14 437 41 250 37 41 35 21 8 32 5 14 25 22 3 5 8 717 1 11 217 3 5 9 125 7 092 8 717 12 5 41 1 0 625 29 21 SQUARE CHASE TOP TERMINATION ROUND TOP TERMINATION CAUTION THE STRUCTURAL INTEGRITY OF THE MANUFACTURED HOME FLOOR WALL AND CEILING ROOF MUS...

Page 5: ...12 Minimum Maximum Chimney Height for Outdoor Installation The minimum height of the chimney mea sured from the base of the fireplace to the flue gas outlet of the termination is 7 1 2 feet minimum of 4 feet of chimney pipe sections required for outdoor installation FRAMING 1 Frame opening for fireplace using dimen sions shown in Figures 1 and 2 21 875 41 75 41 75 Figure 1 Framing Dimensions Figur...

Page 6: ...ving a thermal conductiv ity of K 0 84 BTU IN FT HR F or less at 1 thick For example if material selected has a K factor of 0 25 such as glass fiber the following formula would apply 0 25 x 1 0 0 30 thickness required 0 84 Thermal conductivity K of materials can be obtained from manufacturer or supplier of noncombustible material If hearth extension is to be covered use noncombustible mate rial su...

Page 7: ... more than 1 1 2 from fireplace must not be placed less than 12 from top opening of fireplace NFPA STD 211 Sec 7 3 3 3 Figure 5 Mantel Clearances to Combustible Material The maximum height for the air vent can not exceed 3 feet below the flue gas outlet of the termination CHIMNEY PIPE INNOVATIVE HEARTH PRODUCTS chimney system consists of 12 18 24 36 and 48 snap lock double wall pipe segments plann...

Page 8: ...an then be installed over flue pipe section with hemmed end up Press down on each pipe section until lances securely engage hem on fireplace starter The wire will assure proper spacing between inner and outer pipe sections Note For Canada use chimney parts desig nated HT Opening in collar around chimney at top of fireplace must not be obstructed Never use blown insulation to fill chimney enclosure...

Page 9: ...f properly locked It is not necessary to add screws to keep chimney to gether exception see Figure 10 page 9 USING ELBOW OFFSETS 30E 8DM 1 To achieve desired offset you may install combinations of 12 18 24 36 and 48 length of double wall pipe see offset chart on page 9 and Figure 8 Note For systems with 2 elbow sets mini mum height is 22 feet Maximum height for any system is 50 feet 2 Chimney weig...

Page 10: ... 1 23 3 4 49 1 4 1 1 27 3 4 56 3 4 1 30 60 3 4 1 1 33 66 1 1 36 71 1 1 38 1 4 75 2 41 1 4 80 1 4 1 1 1 45 86 3 4 2 46 3 4 89 1 2 1 1 1 51 97 1 1 53 1 4 101 2 1 56 1 4 106 1 4 2 59 1 4 111 1 2 1 1 1 61 3 4 115 1 2 2 1 64 3 4 120 3 4 2 1 68 1 4 127 1 2 70 130 2 1 1 74 1 4 137 1 2 1 2 1 76 3 4 141 1 2 1 2 1 79 3 4 146 3 4 4 OFFSET CHART 22 50 FT SYSTEM HEIGHT B A Screws 2 Min Straps Straps Straps Str...

Page 11: ...plied around perimeter of flashing to provide a proper seal FIRESTOP SPACERS 3600FS 8DM 1 Firestop spacers are required at each point where chimney penetrates a floor space Their purpose is to establish and maintain required clearance between chimney and combustible materials When pipe passes through a framed opening into a living space above firestop must be placed onto ceiling from below as show...

Page 12: ...ructions provided with the termination being used VENTING INSTALLATION Continued Attach Bracket Tabs to Outer Pipe 3 Places Secure with Screws RTL 8DM Level of Flue Gas Outlet Caulk Collar Flashing Underlap Shingles Bottom Only Figure 16 Termination Overlap Shingles Top and Sides Terminations with 16 slip pipe sections are available RTT 8DM RTTL 8DM and RLTT 8DM are approved for flashing installat...

Page 13: ...stible materials do not overlap face itself Brick glass tile or other noncombustible materials may overlap front face provided they do not obstruct essential openings such as louvered slots When overlapping with a noncombustible facing material use only noncombustible mortar or adhesive 30E 8DM EFFECTIVE HEIGHT OF TERMINATION CAP EFFECTIVE HEIGHT OF TERMINATION CAP EFFECTIVE HEIGHT OF TERMINATION ...

Page 14: ... on either side of fireplace and pull out insu lation from gas line conduit sleeve Save insulation for reuse Note Secure incoming gas line to wood framing to provide rigidity for threaded end 4 Repack insulation around gas line and into sleeve opening Seal any gaps between gas line and refractory knockout hole with refractory cement or commercial furnace cement Install gas appliance or cap off gas...

Page 15: ... WARNING Whenusingadec orative vented gas log damper mustberemovedorpermanently locked in fully open position and glassdoorsmustbeinfullyopen position The following tips should be used to assure that both fireplace and glass door retain their beauty and function properly Both flue damper and glass doors must be fully opened before starting a fire This will provide sufficient combustion air and mai...

Page 16: ...ner or soap and water Do not use any abrasive material to clean glass Do not clean glass with any cool water if glass is still hot from fire and smoke A gas line or gas log lighter may be installed for the purpose of installing a vented or vent free decorative gas appliance incorporating an automatic shutoff device and complying with the Standard for Decorative Gas Appliances for Installation in V...

Page 17: ...NG GUIDELINES The fireplace grate must always be secured to the retaining brackets provided The position of the grate must be centered against the back wall of the firebox Burn only dry seasoned cured wood with less than 20 moisture Avoid the use of treated painted and laminated wood Never burn garbage or other foreign materials Do not use artificial logs colored newspaper or petroleum based fire ...

Page 18: ... smoke continues the combustor has ceased to function or there is thermal crumbling Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 for replacement parts WARRANTY INNOVATIVE HEARTH PRODUCTS war ranty obligations for the PureFire Emissions Control System are limited to the terms set forth below INNOVATIVE HEARTH PRODUCTS war rants to the consumer who purchases a new solid fuel burning fireplace c...

Page 19: ...places US com 127023 01A 19 PARTS WOOD BURNING FIREPLACE MODELS WRE3836WS WRE3836WH WRE3836RS AND WRE3836RH 9 26 16 27 16 27 4 32 34 19 12 25 20 30 17 8 1 5 21 2 35 18 11 14 3 13 22 10 6 31 7 37 38 36 28 29 24 23 15 33 ...

Page 20: ...4 Firebox Support Leg 2 15 Damper Can Collar 1 16 106691 01 Screen Rod 2 17 Firebox Top Assembly 1 18 Air Kit Door Assembly 1 19 Face Weldment 1 20 125562 02 Air Deflector 1 21 Fireplace Top Insulation 1 22 107775 01 Access Panel 1 23 107854 01 Right Refractory Bracket 1 24 107854 02 Left Refractory Bracket 1 25 125186 02 Grate 1 26 11418 Push On Nut 2 27 110890 01 Stainless Screen 2 28 Collar Ins...

Page 21: ...extured White Brick 1 108165 03 Right Refractory Textured White Herringbone 1 106659 02 Right Refractory Textured Red Brick 1 108165 02 Right Refractory Textured Red Herringbone 1 106659 01 Right Refractory Smooth White Brick 1 108165 01 Right Refractory Smooth White Herringbone 1 11 106660 03 Rear Refractory Textured White Brick 1 108166 03 Rear Refractory Textured White Herringbone 1 106660 02 R...

Page 22: ...this product is missing a part or has a broken component please do not return it to the store Call INNOVATIVE HEARTH PRODUCTS at 1 800 655 2008 to answer questions and replace parts under warranty Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When calling or writing please have your model and serial numbers of your fireplace rea...

Page 23: ...ed DRAIN PAN DP36 ANTI DRAFT SHIELD Round Top Termination Only ADS 8DM STORM COLLAR SC1 1 ROUND TOP TERMINATIONS WITH LOUVERS RLT 8DM RLT 8HT ROUND TOP TERMINATIONS WITH LOUVERS WITH SLIP SECTION RLTT 8DM RLTT 8HT SQUARE TOP TERMINATION WITH LOUVERS ET 8DM ET 8HT SQUARE TOP TERMINATION WITH LOUVERS AND SLIP SECTION ETL 8DM ETL 8HT MESH SQUARE TOP TERMINATION ETO 8DM MESH SQUARE TOP TERMINATION WIT...

Page 24: ...ormal use with approved fuels listed in the Operation Manual provided with the product This includes burning such fireplace fuels as wood and natural or propane gas Fuel products with abnormal burning characteristics including but not limited to fuel such as driftwood coal or plywood and wood products using a binder may burn at excessive temperatures and may cause damage to the Product or may caus...

Page 25: ...EEP THIS WARRANTY Model located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep receipt for warranty verification ...

Page 26: ... cannot ship via parcel delivery services IMPORTANT NOTICE A manufactured shroud which has been approved by a national testing agency for use with this fireplace may be used if installed in accordance with the instruc tions by its manufacturer A locally fabricated shroud may be used with IHP Shroud Leg Spacer Kit SLK in accordance with instructions provided with the shroud IMPORTANT NOTICE When pe...

Page 27: ...www SuperiorFireplaces US com 127023 01A 27 NOTES ...

Page 28: ...127023 01 Rev A 01 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P127023 01 ...

Reviews: