When installing the double outlet system, the hot air outlets can be installed
in the same room as the fireplace, or one or both of the outlets can be
installed in adjacent or upper rooms. Installing the ducts at different eleva-
tions will tend to exhaust more heat out of the higher outlet (
Figure 22
).
Frame
Grill
Maintain at least 6-1/2”
(160 mm) clearance from
the outlet grill framing to
a combustible ceiling,
side wall or mantel.
Outlet Grill
Outlet Grill
WARNING: The outlet
grills should not be
installed facing up-
ward through a floor.
Danger of burns can
result if grills in floor
are stepped on.
6-1/2” (165mm)
Min. (to ceiling)
Firestop
10’
(3.1m)
Max.
13” x 13”
(330mm x 330mm)
10’ (3.1m)
Max.
68” Min.
(1727mm)
56” Min.
(1422mm)
Fireplace Blower
The fireplace comes equipped with a heat activated blower. It is located
in the bottom of the fireplace, towards the back. It uses 120 V and must
be connected to the main electrical circuit by a qualified electrician. For
connection, use the electrical box supplied with the unit located on the
bottom right corner of the fireplace.
If you wish to adjust the blower speed, the variable speed control (VRUW)
provided must be installed in line with the wiring. Again, use a qualified
electrician for installation.
If the blower requires servicing,
1- Remove the doors and decorative facade.
2- Remove the screw located below the blower motor that holds it to the
back of fireplace.
3- Pull the blower out of the unit through the square hole located in the
front bottom right corner.
HOT AIR DUCTING INSTALLATION
This fireplace is approved for use with a Gravity Kit:
Gravity Kit
The gravity kit is designed for double hot air outlets and includes:
(See
Figure 21
)
- 2 telescopic lengths 8” I.D.
- 2 90º elbows 8” I.D.
- 2 hot air outlet kits (grill and frames)
- 2 adaptors
See Gravity Kit Accessories on
Page 23
.
Only the blower available with the fireplace can be used with the gravity kit.
For safe installation, the gravity kit must meet the following requirements:
Minimum height*
68” (1,727 mm)
Maximum length
See
Figure 22
* The height of the louver must be measured from the base of the
fireplace to the middle point of the louver.
WARNING: Both pipes of
the double hot air outlet
must be installed. Any oth-
er installation may cause
fire and void warranty.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.