 WARNING: A qualified service person must con-

nect fireplace to gas supply. Follow all local codes.

A gas line may be installed for the purpose of installing a vented 

or vent-free decorative gas appliance available through your local 

distributor. Use only gas piping approved by local codes. When 

installing a gas line, a shutoff valve designed for installation outside 

the appliance is recommended.
The gas pipe is intended for connection to a decorative gas ap-

pliance that operates using natural or propane/LP gas only. This 

appliance must have an automatic shutoff device and must comply 

with the Standard for Decorative Gas Appliances for Installation in 

Vented Fireplace, ANSI Z21.60. ONLY UNVENTED GAS LOG SETS 

WHICH HAVE BEEN FOUND TO COMPLY WITH THE STANDARD FOR 

UNVENTED ROOM HEATERS, ANSI Z21.11.2, ARE TO BE INSTALLED 

IN THIS FIREPLACE.
NOTICE: Before you proceed, make sure your gas supply is turned off.
Use only a 1/2" black iron pipe and appropriate fittings.
1.  Remove knockout indentation on refractory or firebrick wall 

located approximately 2" above the refractory hearth floor. The 

knockout indentation must be firmly tapped with any solid object 

such as a 1/2" dowel until it is released. Remove fragmented 

portions of refractory (see Figure 24).

2.  Remove gas line cover plate located on rear of fireplace and pull 

out insulation from gas line conduit sleeve. Save insulation for 

reuse.

3.  Run gas line into the fireplace through the rear at 11 1/4" from 

floor and through gas line conduit sleeve (if using a raised 

platform, add height). Provide sufficient gas line into fireplace 

chamber for fitting connection (see Figure 25).

  Note: Secure incoming gas line to wood framing to provide rigidity 

for threaded end.

4.  Repack insulation around gas line and into sleeve opening. Seal 

any gaps between gas line and refractory knockout hole with 

refractory cement or commercial furnace cement, Install the gas 

appliance or cap off gas line if desired.

 CAUTION: All gas piping and connections must be 

tested for leaks after installation is completed. After 

ensuring that gas valve is on, apply soap and water 

solution to all connections and joints. Bubbles forming 

show a leak. Correct all leaks at once. DO NOT USE 

AN OPEN FLAME FOR LEAK TESTING AND DO NOT 

OPERATE ANY APPLIANCE IF A LEAK IS DETECTED. 

LEAK TESTING SHOULD BE DONE BY A QUALIFIED 

SERVICE PERSON.

Note: An IHP hood must be installed when using an unvented gas 

log set (see Accessories on page 16).

 WARNING: Do not operate an unvented gas log 

set in this fireplace with chimney removed.

Figure 25 - Gas Line Installation

OPTIONAL GAS LINE INSTALLATION

Figure 24 - Gas Line Knockout

Side 

Firebrick 

Finished 

Side

Refractory 

Knockout 

Plug

Outside of Fireplace

Gas Line 

Conduit

Insulation

Gas 

Conduit 

Cover

1/2" Dowel

Seal 

Opening 

with 

Refractory 

Cement

Outside of 

Fireplace

Gas 

Line 

Conduit

Repack 

Insulation

Incoming 

1/2" Black 

Iron Pipe

Side 

Firebrick 

Finished 

Side

Provide Enough 

Threaded End for 

Fitting Connection

If you install a decorative gas appliance (vented gas log), decorative 

gas appliance must comply with the Standard for Decorative Gas 

Appliance for Installation in Solid Fuel Burning Fireplaces, ANSI 

Z21.60/CSA 2.26 or Z21.84 and shall also be installed in accordance 

with ANSI Z223.1/NFPA 54 National Fuel Gas Codes (USA) and CAN/

CGA-B149.1 National Gas And Propane Installation Code (Canada).

 

WARNING: To avoid the risk of damaging fireplace 

materials and increasing the risk of spreading a fire, 

do not use fireplace to cook or warm food.

 WARNING: If the fireplace has been used for wood 

burning, firebox and chimney must be cleaned of soot, 

creosote and ashes be a qualified chimney cleaner. 

Creosote will ignite if heavily heated.

 WARNING: When using a decorative vented gas 

log, damper must be removed or permanently locked 

in fully open position and glass doors must be in fully 

open position.

Summary of Contents for WCT40CLWSI

Page 1: ...r use as a wood burning fireplace or for use with a vented gas log approved to ANS Z21 60 Z21 84 standards or for use with a vent free gas log heater approved to ANS Z21 11 2 standard An INNOVATIVE HE...

Page 2: ...ponents are safe when installed according to this installation manual Unless you use IHP com ponents which have been designed and tested for the fireplace system you may cause a fire hazard The IHP wa...

Page 3: ...to treat insects and fungus When burned thesechemicalscanposeasignificanthazard WARNING BURNING IMPROPER FUEL I E CHARCOAL CAN RESULT IN CARBON MONOXIDE POISONING WHICH MAY LEAD TO DEATH Carbon Monoxi...

Page 4: ...WARNING Children and adults should be alerted to the hazards of high surface temperatures and to stay away to avoid burns or clothing ignition Young children should be carefully supervised when in the...

Page 5: ...1 2 minimum WARNING DO NOT PACK REQUIRED AIR SPACES WITH INSULATION OR OTHER MATERIALS Do not obstruct fireplace openings ie louvers etc with any type of facing material Combustible mate rial must no...

Page 6: ...such as tile slate brick concrete metal glass marble stone etc Provide a means to prevent hearth extension from shifting and seal gap between fireplace frame and hearth extension with a non combustib...

Page 7: ...n with two elbow sets 24 feet An elbow set consists of one starter elbow and one return elbow Uncommon circumstances such as neighboring hills tall trees or strong wind areas can cause downdrafts in c...

Page 8: ...5 8 18 8DM Pipe Section 16 5 8 24 8DM Pipe Section 23 5 8 36 8DM Pipe Section 34 5 8 48 8DM Pipe Section 46 5 8 RT 8DM Round Termination 6 7 8 RTL 8DM Round Termination 7 3 4 RTT 8DM Round Termination...

Page 9: ...oint where the chimney pen etrates a floor or ceiling joist space Their purpose is to establish and maintain the required clearance between the chimney and the combustible materials When the pipe pass...

Page 10: ...e 16 This support is designed to relieve extra weight load on fireplace and elbows when high chimneys are installed Figure 16 Support Sections 30 FT 30 FT 12S 8DM Support Return Elbow Effective Height...

Page 11: ...upport wires may be at tachedtoouterpipeofchimneywithscrewsprovided screws do not penetrate inner flue pipe Figure 20 Storm Collar Chimney Pipe Waterproof Caulk Storm Collar Flashing FLASHING INSTALLA...

Page 12: ...manufac turer for specifications 10 FOOT RULE All chimney terminations must extend a minimum of 3 above the highest point where it passes through the roof and must be at least 2 above roof with a 10...

Page 13: ...gas line and refractory knockout hole with refractory cement or commercial furnace cement Install the gas appliance or cap off gas line if desired CAUTION All gas piping and connections must be teste...

Page 14: ...ng a fireplace system in a cold climate area Following these steps will aid in reducing cold air infiltration from fireplace enclosure into living space 1 Fireplace must be placed on a solid continuou...

Page 15: ...S OF BOTH FIRE AND SMOKE OPERATION AND MAINTENANCE GUIDELINES Continued Cleaning Glass Clean glass with any commercial glass cleaner or soap and water Do not use any abrasive material to clean glass D...

Page 16: ...ft 20128 Right SCREEN 12111 Not Shown PUSH ON NUT 11418 Not Shown SCREEN ROD 20806 Not Shown CHIMNEY SUPPORT 12S 10DM FIRESTOP SPACER FS 8DM DOUBLE WALL 30 ELBOW OFFSET 30E 8DM Return Elbow Starter El...

Page 17: ...N ETL 8DM ETLO 8DM BI FOLD GLASS DOOR VDBP36C Black VDG36C Brushed Brass DC36L R LS RS Platinum ACCESSORIES Continued FAN KIT VCBK4C LEFT VCBK4R RIGHT OUTSIDE AIR KIT FOR SIDE WALL INSTALLATION AK4F O...

Page 18: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 19: ...____________________________________ ______________________________________________________ ______________________________________________________ _____________________________________________________...

Page 20: ...design materials specifications pricesandalsotodiscontinuecolors stylesandproducts Consult your local distributor for fireplace code information Printed in U S A 2013 IHP LLC P N 126607 01 Rev A 12 20...

Reviews: