Superior VRL4543ZEN Installation And Operation Instructions Manual Download Page 19

SuperiorFireplaces.us.com

126861-01L

19

Figure 30 - Turning Equipment Shutoff Valve to the OFF Position

MAIN

IN

OUT

PILOT

ADJ

PILOT

Equipment Shutoff Valve

Incoming 

Gas Line

OPERATING FIREPLACE

FOR YOUR SAFETY 

READ BEFORE LIGHTING

 WARNING: If you do not follow these instructions 

exactly, a fire or explosion may result causing property 

damage, personal injury or loss of life.

A.  This appliance is equipped with an ignition device which au-

tomatically lights the pilot. Do not light pilot by hand.

B.  BEFORE LIGHTING smell all around the appliance area for gas. 

Be sure to smell next to the floor because some gas is heavier 

than air and will settle on the floor.

  WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in your 

building.

• Immediately call your gas supplier from a neighbor’s phone. 

Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire department.

C.  Do not use this appliance if any part has been under water. Imme-

diately call a qualified service technician to inspect the appliance 

and to replace any part of the control system and any gas control 

which has been under water.

LIGHTING 

INSTRUCTIONS

 NOTICE: During initial operation of new heater,paint 

will give off a paper-burning smell. Orange flame will 

also be present. Open damper or window to vent 

smell. This will only last a few hours.

This appliance requires 120V electricity for normal operation. Control 

module should be plugged into electrical outlet located underneath 

firebox bottom. Back up battery supply is available for power outages.

1.  STOP! Read the safety information, column 1.
2.  Make sure equipment shutoff valve is fully open.
3.  Turn safety shutoff switch to the OFF position.
4.  Remove access cover.
5.  Turn equipment shutoff valve clockwise to the OFF position

 (see 

Figure 30

).

 Do not force.

1.  Wait five (5) minutes to clear out any gas. Then smell for gas, 

including near the floor. If you smell gas, STOP! Follow “B” in 

the safety information. If you don't smell gas, go to the next step.

2.  Turn equipment shutoff valve counterclockwise to the ON posi-

tion. Do not force.

3.  Replace access cover.
4.  Turn on all electric power to appliance.
5.  Turn safety shutoff switch to the ON position.
6.  Visually locate pilot. Igniter should begin to spark and main 

burner should ignite once flame appears at pilot.
•  If lighting appliance for the first time each season, it may 

take several attempts before supply gas can reach pilot 

and main burners.

•  If appliance will not stay lit after several attempts, follow 

instructions under To Turn Off Gas To Appliance and call 

your service technician or gas supplier.

 CAUTION: Do not try to adjust heating levels by 

using the equipment shutoff valve.

TO TURN OFF GAS 

TO APPLIANCE

1. Turn off safety shutoff switch.
2. Turn off all electric power to appliance if service is to be performed.
3. Remove center brick/control cover.
4. Turn equipment shutoff valve clockwise to OFF. Do not force.
5. Replace access cover.

Summary of Contents for VRL4543ZEN

Page 1: ...stion and ventilation air must be provided Refer to Air for Combustion and Ventilation section on Page 6 of this manual PFS US Report No F11 054 WARNING FIRE OR EXPLOSION HAZARD Failure to follow safe...

Page 2: ...bited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases IMPORTANT Read this owner s manual car...

Page 3: ...ture 10 This fireplace needs fresh air ventilation to run properly This fireplace has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fireplace if not enough fresh air is...

Page 4: ...he individual manual shut off must be a T handle type valve Unvented appliances may NOT be installed in bedrooms or bathrooms A working smoke detector must be installed in the area where vent free app...

Page 5: ...hich the appliances are installed through openings not furnished with doors are considered a part of the unconfined space This appliance shall not be installed in a confined space or unusually tight c...

Page 6: ...ventilation grills between rooms See Ventilation Air From Inside Building B Vent room directly to the outdoors See Ventilation Air From Outdoors C Install a lower Btu Hr fireplace if lower Btu Hr siz...

Page 7: ...ealer where you bought fireplace for proper type fireplace WARNING This appliance is equipped for either natural gas or propane LP gas but not both Gas type is indicated on the rating plate Field conv...

Page 8: ...D 16 5 2 E 14 A B C D E 1 2 3 4 5 Wall Supplied firebox hood must be used at all times Note All vertical measurements are from top of fireplace hood opening to bottom of mantel shelf Noncombustible ma...

Page 9: ...1 2 29 5 8 29 5 8 16 3 8 7 1 8 1 7 8 8 1 4 44 1 8 1 1 55 1 8 52 47 16 1 2 11 3 4 8 1 4 5 8 INSTALLATION Continued Figure 8 VRL4543 Series Dimensions Electrical Outlet Gas Line Access Gas Line Access...

Page 10: ...propane LP supply This fireplace requires anexternalregulator notsupplied Installtheexternal regulatorbetweenthefireplaceandpropane LPsupply WARNING Never connect natural gas fireplace to private non...

Page 11: ...diment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into fireplace gas controls If sediment trap is not installed or is...

Page 12: ...lve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve see Figure 13 2 Pressurize supply piping system by either o...

Page 13: ...a guide screw the rear panel to the fireplace as shown in Figure 16 INSTALLING HOOD 1 Loosen screws at top of face opening and slide hood through screws as shown in Figure 17 2 Tighten screws securing...

Page 14: ...ont of the fireplace unscrew 4 corner brackets from the firebox top See Figure 21 2 Remove 2 side walls and then the rear wall Discard rear wall 3 Replace 2 side walls and reinstall the corner bracket...

Page 15: ...ner shuts OFF Figure 26 Gas Module Right Side Figure 27 Gas Module Left Side Remote Control Feature The module has a built in remote control receiver that allows the user to program the remote transmi...

Page 16: ...supplied with the unit into the battery compart ment It is recommended that ALKALINE batteries always be used for this product Be sure the batteries are installed with the and ends facing the correct...

Page 17: ...tory default or degrees C Press the UP and DOWN Buttons simultaneously to change between degrees F and C SET TEMP While in THERMOSTAT mode press the UP or DOWN Button to change the SET TEMP 45 90 deg...

Page 18: ...Flame A setting number will flash in the FLAME Zone REMOTE CONTROL OPERATION Continued LIGHT ADJUSTMENT Transmits a light setting command to the control module to adjust the light output level Availa...

Page 19: ...is appliance requires 120V electricity for normal operation Control module should be plugged into electrical outlet located underneath firebox bottom Back up battery supply is available for power outa...

Page 20: ...ecommend using compressed air no greater than 30 PSI Your local computer store hardware store or home center may carry compressed air in a can If using compressed air in a can please follow the direct...

Page 21: ...the fireplace running Some burner flame holes may become blocked by debris or rust with no flame present If so turn off fireplace and let cool Remove blockage Blocked burner flame holes will create so...

Page 22: ...ot Main HI LO DC Motor Drive Light Module Black Black Brown Red Orange Orange To Ground Igniter Sensor PILOT BATTERY PACK WIRING DIAGRAM Black Blk White SIZE AA SIZE AA SIZE AA SIZE AA Blk Brown Yello...

Page 23: ...ontact local propane LP gas company 3 Clean ODS pilot see Cleaning and Main tenance Page 20 or replace ODS pilot assembly 4 Replace gas regulator 1 Contact local natural or propane LP gas company 2 Cl...

Page 24: ...cting while cooling 1 Burner orifice is clogged or damaged 2 Damaged burner REMEDY 1 Check burner for dirt and debris If found clean burner see Cleaning and Mainte nance Page 20 1 Refer to Air for Com...

Page 25: ...LP only 3 Gas leak See Warning statement above 1 Not enough fresh air is available 2 Low line pressure 3 ODS pilot is partially clogged 1 Gas leak See Warning statement above 2 Control valve or gas co...

Page 26: ...SuperiorFireplaces us com 126861 01L 26 PARTS MODELS VRL4543ZEN VRL4543ZEP 11 7 4 3 8 8 8 8 14 15 16 17 18 19 20 24 21 5 22 23 6 2 1 13 10 9 12 Cat No Description F1186 VRL4543ZEN F1187 VRL4543ZEP...

Page 27: ...694 Burner Gasket 2 14 J6737 Electronic Access Cover 1 15 J8032 Insulation Heatshield 1 16 J6718 Module Extension 1 17 J6570 Bracket Valve Components 1 18 J6738 Insulation Heatshield 1 19 RP125072 03...

Page 28: ...SuperiorFireplaces us com 126861 01L 28 PARTS MODELS VRL4543ZEN VRL4543ZEP 1 4 6 2 8 9 7 5 3 5 11 12 13 14 10 7 8...

Page 29: ...d by IHP Use of non approved parts can result in poor performance and safety hazards KEY NO CATALOG NO DESCRIPTION VRL4543ZEN F1186 VRL4543ZEP F1187 QTY 1 J6630 Top Spacer 4 2 J6566 Top Nailing Flange...

Page 30: ...ace Trim for 43 Linear Fireplace Aged Silver F1038 DFT43AC Decorative Face Trim for 43 Linear Fireplace Aged Copper LINEAR SEE THRU CONVERSION KITS Not Shown F1030 LVSTI Linear VF See Thru Conversion...

Page 31: ...natural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard...

Page 32: ...tributor for fireplace code information Printed in U S A 2013 Innovative Hearth Products P N 126861 01 Rev L 02 2019 1769 East Lawrence Street Russellville AL 35654 SuperiorFireplaces us com Record th...