Finished Wall Details

It is sometimes best to frame the appliance
after it has been positioned in place. Frame with
2 x 4s or heavier lumber. Always frame in
accordance with local building codes.

Note:

 The header may rest on the top spacers

but must not be notched to fit around them.

In order to install the appliance facing flush with
the finished wall, position the framework to
accommodate the thickness of the finished wall
(

Refer to Figures 2, 3 and 5 ).

If you live in a cold climate, seal all cracks
around your appliance with noncombustible
material and wherever cold air could enter the
room.  It is especially important to insulate
outside chase cavity between studs and under
floor on which appliance rests, if floor is above
ground level.

CAUTION:  DO NOT CONNECT THE OPTIONAL
REMOTE SWITCH TO A 120V POWER SUP-
PLY.

Note: 

The optional rocker switch is mounted to

the appliance and wired in the same way as the
remote wall switch.

Step 7. Installing the Optional Forced Air
Blower Kit Wiring –

 A receptacle plate is pro-

vided for the installation of the FAB-1100 forced
air blower kit (optional).  Electrical power must
be provided to this plate to operate the blower.

Route a 3-wire, 120Vac power line with control
switch to the lower left front corner of the
appliance. Supply wires are to be connected to
the outlet as shown in 

Figure 11, ensuring that

the polarity (as determined by the colors of the
wires) is exactly as shown.  The black and red
wire loop must be left intact, with the mating
connectors connected.

IMPORTANT: Ground lead must be connected
to the green screw located on the junction box
cover plate. Failure to do so will prevent the
appliance from operating.

 The appliance must

be electrically grounded in accordance with
local codes or, in the absence of local codes, the
National Electrical Code, ANSI/NFPA 70-(latest
edition). (In Canada, the current CSA C22-1
Canadian Electrical Code.)

The forced air blower kit may be mounted at
initial appliance installation or at any time there-
after. Follow the instructions provided with the
blower kit.

Figure 11

White
(Supply)

Black
(Supply)

Bipolar
Terminal
Screw

Blower
(Lower)
Outlet

Black
Wire

Mating
Connectors

Red Wire

120 Vac
 60 Hz

Blower Wiring Diagram

}

OFF/ON Blower

Wall Switch

To Fuse or
Circuit Breaker

120V

AC

60Hz

Fireplace
Junction Box

Black

White

Receptacle

Ground Wire
Connection

Note: 

 Supply wires may be alternatively connected to the outlet using the screw terminals, however

the black supply wire must be ganged wired to the same terminal that the pre-wired black wire is
attached to and the white supply wire must be connected to the opposite side of the outlet.

VFST Series

Standard Wiring Diagram

TPTH

TP

TH

Thermopile

If any of the original wire as supplied must be replaced, it
must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

* For Rocker or ON/OFF Wall Switch Attachment Only.

*

*

From Thermocouple

VFST Series

Optional Wiring Diagram

TPTH

TP

TH

Thermopile

If any of the original wire as supplied must be replaced, it
must be replaced with

 

Type AWM 105

°

C – 18 GA. wire.

Optional ON/OFF

Wall Switch/Rocker Switch

Factory Wired

Field Wired

*

* For Rocker Switch Attachment Only.

*

From Thermocouple

Figure 10

Figure 9

Summary of Contents for VFPF-CMN

Page 1: ...your gas sup plier from a neighbor s phone Follow the gas supplier s in structions If you cannot reach your gas supplier call the fire depart ment Installation and service must be performed by a quali...

Page 2: ...necessarypartsinusablecondition Also check for concealed damage IMPORTANT SAFETY INFORMATION INSTALLER PLEASELEAVETHESEINSTRUC TIONS WITH THE OWNER OWNER PLEASE RETAIN THESE INSTRUC TION FOR FUTURE RE...

Page 3: ...xample VFST Vent free heater 32 000 BTU Hr Gas appliance 1 34 000 BTU Hr water heater Total 66 000 BTU Hr Do not include direct vent gas appliances Direct vent is sealed combustion and draws combustio...

Page 4: ...or local codes Aftermarket Completion of sale not for pur pose of resale from the manufacturer Minimize modifications to existing con struction To ensure even heat distribution it is best to position...

Page 5: ...tion is unique however and might require a different sequence CAUTION HEATERSCREATEWARMAIRCUR RENTS THESE CURRENTS MOVE HEAT TO WALLSURFACESNEXTTOHEATER INSTALL INGHEATERNEXTTOVINYLORCLOTHWALL COVERIN...

Page 6: ...cket Bracket Bracket Figure 3 Figure 4 Figure 5 A 22 578 mm B 43 1099 mm Min C 43 1092 mm Min Framing Dimensions Note Framing dimensions calculated for drywall finish Front View VFST 42 1086 mm 40 101...

Page 7: ...ket Bracket Framing Top View 13mm Required Air Space Clearance A 22 578 mm B 40 1016 mm Min C 43 1092 mm Min Framing Dimensions Note Framing dimensions calculated for drywall finish End View 18 457 mm...

Page 8: ...valve replacing the nipple providedwiththeapplianceandorientedtothe rear 2 a6 3 8 nippleand 3 a3 8 standard elbow returning to the left and aligning with a gas line routed through the left hand openi...

Page 9: ...intact with the mating connectors connected IMPORTANT Ground lead must be connected tothegreenscrewlocatedonthejunctionbox cover plate Failure to do so will prevent the appliancefromoperating Theappl...

Page 10: ...LAMES Flames from the pilot front and rear burner should be visually checked as soon as the heater is installed In addition a periodic visual check of the flames should be made The pilot flameshouldal...

Page 11: ...ppli ance will not require such purging Inspect the pilotflame removelogs ifnecessary handling carefully The pilot flame should be steady not lifting or floating Flame should be blue in color with tra...

Page 12: ...t is de signed to be wired directly to the appliance millivolt gas control circuit and provide auto matic On Off control of the appliance to main tain a desired temperature within the room Solid Brass...

Page 13: ...FC 1110 West Taft Avenue Orange CA 92865 OPERATION AND CARE OF YOUR APPLIANCE 1 Appliance operation may be controlled throughtheoptionalON OFFunitrockerswitch located in the lower control compartment...

Page 14: ...he DAT 6 1 or DAT 6 4 4 Piece Decorative Arch Frame Kit Main Panel DAT 6 4 End Panel DAET 6 4 Brass Surround Kit Main Panel BSK 6 End Panel BSEK 6 1 Piece Decorative Arch Frame Kit Main Panel DAT 6 1...

Page 15: ...orifice Replace burner Replace gas regulator Problem will stop after a few hours of operation SFC recommends running the heater with excess ventilation for the first few hours Turn control knob to LO...

Page 16: ...the gas while the probe is warming up 10 Release the control knob while turning counterclockwise to the ON Position Figure 21 Then adjust HI LO knob to prefered setting If the knob does not pop out w...

Page 17: ...not force Figure 18 Pilot Location Figure 19 Pilot Figure 20 Turn Control Knob to OFF Position Turn Control Knob to PILOT Position E A TPTH TP TH PILOT H I LO W PILOT O N it O F F E A TPTH TP TH PILO...

Page 18: ...18 1 112081 1 5 Burner 112281 1 112281 1 6 Burner Pilot Side 112291 1 112291 1 7 Crossover Burner 110321 1 110321 1 8 Injector Crossover Burner 110387 1 110388 1 9 Piezo 111061 1 111061 1 10 Piezo Wir...

Page 19: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 19 REPLACEMENT PARTS VFST 11 7 8 6 2 14 1 4 9 10 12 15 13 12 3 5 16...

Page 20: ...21 1 8 Injector Crossover Burner 110387 1 110388 1 9 Piezo 111061 1 111061 1 10 Piezo Wire 110361 1 110361 1 11 Log Set 112451 1 112451 1 12 Bar Louver Black Main Panel 104951 8 104951 8 13 Two Piece...

Page 21: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 21 REPLACEMENT PARTS VFPF 15 12 16 20 19 19 9 18 13 12 1 14 3 11 6 2 1 10 9 17 4 7 8 5...

Page 22: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 22...

Page 23: ...NOTE DIAGRAMS ILLUSTRATION NOT TO SCALE 23...

Page 24: ...or propane gas only Burning conventionalfireplacefuelssuchaswood coal oranyothersolidfuelwillcausedamagetotheUnventedGasRoomHeater willproduceunsafelevelsofcarbonmonoxide and will result in a fire ha...

Reviews: