background image

www.lennoxhearthproducts.com

126543-01A

4

SAFETY

Continued

3.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a  neighbor’s  phone.  Follow  the  gas 

supplier’s instructions

• if you cannot reach your gas supplier, 

call the fire department

4.  This fireplace shall not be installed in a 

bedroom or bathroom.

5.  Do not use this fireplace as a wood-burn

-

ing fireplace. Use only the logs provided 

with the fireplace.

6.  Do not add extra logs or ornaments such 

as pine cones, vermiculite, or rock wool. 

Using these added items can cause soot-

ing. Do not add lava rock around base. 

Rock and debris could fall into the control 

area of fireplace.

7.  To prevent the creation of soot, follow the 

instructions in 

Cleaning and Maintenance

page 24.

8.  Before using furniture polish, wax, carpet 

cleaner, or similar products, turn heater 

off. If heated, the vapors from these prod

-

ucts may create a white powder residue 

within burner box or on adjacent walls or 

furniture.

9.  This fireplace needs fresh air ventilation to 

run properly. This fireplace has an Oxygen 

Figure 1 - Log Base Assembly

Top Outer Casing

Figure 2 - Fireplace

Log Set

Base 

Assembly

Front 

Burner

Depletion Sensing (ODS) safety shutoff 

system. The  ODS  shuts  down  the  fire

-

place if enough fresh air is not available. 

See 

Air for Combustion and Ventilation

page 6. If fireplace keeps shutting off, see 

Troubleshooting

, page 25.

10. Do not run fireplace

• where flammable liquids or vapors are 

used or stored

• under dusty conditions

11. Do not use this fireplace to cook food or 

burn paper or other objects.

12. Do not use fireplace if any part has been 

exposed to or under water. Immediately 

call  a  qualified  service  technician  to  in

-

spect the fireplace and to replace any part 

of the control system and any gas control 

which has been under water.

13. Do not operate fireplace if any log is 

broken. Do not operate fireplace if a log 

is chipped (dime-sized or larger). 

14. Turn fireplace off and let cool before 

servicing. Only a qualified service person 

should service and repair fireplace.

15. Operating  fireplace  above  elevations  of 

4,500 feet could cause pilot outage.

16. To prevent performance problems in 

propane/LP units, do not use propane/LP 

fuel tanks of less than 100 lbs. capacity 

(propane/LP units only).

17. Provide adequate clearances around air 

openings.

PRODUCT IDENTIFICATION

Top panel 

Assembly

Fireplace 

Hood

Bottom Panel 

Assembly

Screen 

Assembly

Magnet

f i r e - p a r t s . c o m

Summary of Contents for SVFS32NRK

Page 1: ...llyourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied...

Page 2: ...from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on page 6 of this manual This appli...

Page 3: ...lame patterns Ceiling fans can create drafts that alter burner flame patterns Altered burner patterns can cause sooting Due to high temperatures the appliance should be located out oftrafficandawayfro...

Page 4: ...Figure 1 Log Base Assembly Top Outer Casing Figure 2 Fireplace Log Set Base Assembly Front Burner Depletion Sensing ODS safety shutoff system The ODS shuts down the fire place if enough fresh air is n...

Page 5: ...Push the bottom corners of the screen in and release The screen will pop out at the bottom Grasp the bottom of the screen lift the screen up and pull out to remove 3 Remove protective packaging appli...

Page 6: ...ll fireplace plus any adjoining rooms with door less passageways or ventilation grills between the rooms 1 Determine the volume of the space length x width x height Length x Width x Height __________c...

Page 7: ...dditional fresh air Your options are as follows A Rework worksheet adding the space of an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventilatio...

Page 8: ...nlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts You must provide two perma nent openings on...

Page 9: ...ed with the fireplace is to be used it must be wired to a 120 volt supply by a certified electrician OPTIONAL PANELS Each fireplace is shipped with louvered panels installed Smooth panels are also shi...

Page 10: ...ge 14 9 Route blower electrical cord through ac cess holes in either side of fireplace CONVENTIONAL FIREPLACE INSTALLATION Conventional installation of this fireplace involves installing fireplace alo...

Page 11: ...INSTALLATION Continued Figure 12 Inserting Fireplace Into Cabinet Mantel BUILT IN FIREPLACE INSTALLATION Built in installation of this fireplace involves installing fireplace into a framed in enclosu...

Page 12: ...cing WARNING Do not allow any combustiblematerialstooverlap the firebox front facing IMPORTANT Noncombustible materials such as brick tile etc may overlap the front facing but should never cover any n...

Page 13: ...leet CAUTION Use only new black iron or steel pipe Inter nally tinned copper tubing may be used in certain areas Check your local codes Use pipe of 1 2 diameter or greater to allow proper gas volume t...

Page 14: ...erly INSTALLATION Continued Figure 17 External Regulator on Propane LP Supply Tank with Vent Pointing Down External Regulator Propane LP Supply Tank Vent Pointing Down CONNECTING FIREPLACE TO GAS SUPP...

Page 15: ...exible gas line is provided to allow accessibility fromthefireplace seeFigure20 The flexible gas supply line con nection to the equipment shutoff valve should be accessible CHECKING GAS CONNECTIONS WA...

Page 16: ...Propane LP Gas Propane LP Supply Tank Figure 22 Checking Gas Joints for Natural Gas Gas Control Valve Equipment Shutoff Valve Equipment Shutoff Valve Gas Meter Gas Control Valve Open Closed Equipment...

Page 17: ...s to rest against the front of the base assembly Make sure the flame from the ember pan does not touch the ember bed log 5 The left middle log has a groove on the bottom to sit on the chassis and has...

Page 18: ...ly as shown in Figure 31 9 Place the left top log onto the rear log and the left middle log Make sure to place the projection on the bottom of the left top log into the recessed areas on the rear and...

Page 19: ...lace when it is placed over a shoulder screw Place the ember chunks as shown in Fig ure 35 on page 20 by placing the ember chunk with the number 1 on the left 2 in the center and 3 on the right These...

Page 20: ...nk 1 Ember Chunk 2 Ember Chunk 3 Flat Front Burner Figure 38 Installing Fireplace Screen Magnets Screen Bracket 4 Installfireplacescreenbyplacingthescreen brackets on top of the fireplace screen brack...

Page 21: ...e appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Youmustoperate this fireplace with the fireplace screen in place...

Page 22: ...t a qualified service person or gas supplier for repairs Note If pilot goes out repeat steps 4 through 8 beginning on page 21 9 Slightly push in and turn control knob coun terclockwise to the ON posit...

Page 23: ...ireplace could pro duce increased levels of carbon monoxide Follow instructions below Yellow flame on rear burner is normal NOTICE Do not mistake orange flames with yellow tipping Dirt or other fine p...

Page 24: ...amage BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE The primary air inlet holes allow the proper amount of air to mix with the gas This provides a clean burning flame Keep these holes clear of dust...

Page 25: ...in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Reconnect ignitor cable 2 Free ignitor cable if pinched by any metal or tubing...

Page 26: ...enance page24 or replace burner orifice s 1 Clean burner see Cleaning and Maintenance page 24 or replace burner orifice s 2 Replace damaged burner 3 Replace gas regulator 1 Check burner for dirt and d...

Page 27: ...1 Replace 9 volt batteries in receiver and remote control 1 Read EMBER PLACE MENT and correct per in structions 2 Replace orifice Call techni cal service 3 Check burner s for dirt and debris If found...

Page 28: ...nance page 24 1 Locate and correct all leaks see Checking Gas Con nections page 15 2 Replace control valve or gas control 1 Take apart gas tubing and remove foreign matter 2 Locate and correct all lea...

Page 29: ...PARTS Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty When ordering repair parts always give the following information 1 The model...

Page 30: ...01A 30 PARTS LOG BASE ASSEMBLY MODELS SVFS32NRK SVFS32PRK SVFS36NRK AND SVFS36PRK See page 32 for part numbers 1 2 3 5 29 30 4 7 40 13 21 27 11 10 14 16 15 24 12 36 18 37 38 17 39 35 31 20 32 33 19 2...

Page 31: ...06 Valve Gas LP 0 820 642 1 15 103784 01 Knob Short Extension Pilot 1 16 103784 02 Knob Short Extension HI LO 1 17 107634 01SA Plate NG Conversion 1 18 111435 04 Ignitor Electronic 1 19 112465 01 Burn...

Page 32: ...01004 10 Orifice 0453 1 15MM Middle 1 37 111819 10 Orifice Elbow P53 95 110 Pan 1 099056 45 Orifice 0 028 0 711MM Pan 1 111819 11 Orifice Elbow P53 95 300 Pan 1 38 124933 01 Orifice Holder 90 Degree E...

Page 33: ...Panel Closure Smooth 2 106651 01 Panel Closure Smooth 2 2 108423 02 Panel Face Top 32 Stamped 2 106684 01 Panel Closure Top Louvered 36 2 3 110037 01 Electrical Duct Assembly 1 4 20280 Spacer Top 4 5...

Page 34: ...Middle 1 7 125851 07 125852 07 Log Right Middle 1 8 125851 08 125852 08 Log Rear Middle 1 9 125851 09 125852 09 Log Rear 1 10 125851 10 125851 10 Log Left Top 1 11 125851 11 125852 11 Log Middle Cros...

Page 35: ...r unfinished mantel or wall open ing edges etc BRICK LINER KITS SBLQ32SVF 32 Brick Liner Kit SBLQ36SVF 36 Brick Liner Kit NOTICE All accessories may not be available for all fireplace models Purchase...

Page 36: ...126543 01 Rev A 07 13 1508 Elm Hill Pike Suite 108 Nashville TN 37210 www lennoxhearthproducts com fire parts com...

Reviews: