background image

 

 

Installation and Operation Instructions

Models

PFS

®

US

Report No. 10-87

P/N 900463-01   Rev. A  01/2016

Superior

®

 

Unvented (Vent-Free) Gas Log Heater

MNF24INM MNF30INM MNF24INV  MNF30INV

MNF24IPM MNF30IPM MNF24IPV  MNF30IPV

P900463-01

For use with log sets

LMF24GTA/B
LMF30GTA/B
LMF36GTA/B

LMF24MOA/B
LMF30MOA/B
LMF36MOA/B

 -  Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of this or any other appli-

ance.

 -  WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance. 
•  Do not touch any electrical switch; do not use any phone in your building. 
•  Leave the building immediately.
• Immediately call your gas supplier from a neighbor’s phone.  Follow the gas supplier’s instructions. 
•  If you cannot reach your gas supplier, call the fi re department.

 -  Installation and service must be performed by a qualifi ed installer, service agency or the gas supplier.

       

WARNING:

FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or property damage.

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.

This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not 
prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This 
appliance is not convertible for use with other gases.

WARNING: This appliance is for installation only in a solid-fuel burning masonry or UL127 factory-built 
fi replace or in a listed ventless fi rebox enclosure. It is design-certifi ed for these installations in accordance 
with ANSI Z21.11.2. Exception: DO NOT install this appliance in a factory-built fi replace that includes 
instructions stating it has not been tested or should not be used with unvented gas logs.

This is an unvented gas-fi red heater. It uses air (oxygen) from the room in which it is installed. Provisions 
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation 
section on 

Page 6

 of this manual.

 

Summary of Contents for MNF24INM

Page 1: ...llow safety warnings exactly could result in serious injury death or property damage INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference This appliance may...

Page 2: ...ed appli ance It uses air oxygen from the room in which it is installed Provisions for adequate combustion and ventilation air must be provided Refer to Air for Combustion and Ven tilation section on...

Page 3: ...nd liquids WARNING Thisproductcon tainsand orgenerateschemicals known to the state of California to cause cancer or birth defects or other reproductive harm IMPORTANT Read this owner s manualcarefully...

Page 4: ...ar products turn appliance off If heated the vapors from these prod ucts may create a white powder residue within burner box or on adjacent walls and furniture 10 This appliance needs fresh outside ai...

Page 5: ...hand held thermostat may not be used where vented decorative list ing is required Variable remote control models include a ther mostat remote control UNPACKING CAUTION Donotremovethe data plates from...

Page 6: ...nces PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation All spaces in homes fall into one of the three followi...

Page 7: ...installed in that space and an unconfined space as a space whose volume is not less than 50 cubic feet per 1 000 Btu hr 4 8 m3 per kw of the aggregate input rating of all appliances installed in that...

Page 8: ...so remove door into adjoining room see option 3 Figure 2 Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Air for Combustion and Ventilation for required size of ventilation grills or ducts Figur...

Page 9: ...on air may cause mildew to form from too much moisture See Air for Combustion and Ventilation Page 6 CHECK GAS TYPE Use the correct type of gas natural or propane LP If your gas supply is not the corr...

Page 10: ...Clearances If Not Using Mantel NOTE If using a mantel proceed to If Using Mantel If not using a mantel follow these instructions You must have noncombustible material s above the fireplace opening No...

Page 11: ...e Flooring NOTICE Surface temperatures ofadjacentwallsandmantelsbe comehotduringoperation Walls and mantels above the firebox may become hot to the touch If installed properly these tem peratures meet...

Page 12: ...mper clamp will keep damper open Installation instructions are included with clamp accessory See chart below for minimum permanent flue opening you must provide Attach damper clamp so the minimum perm...

Page 13: ...rtar joint of bricks 4 Remove appliance base from fireplace 5 Drill holes at marked locations using 3 16 drill bit 6 Attachbase throughholesinbacksidepan els of base to fireplace floor using masonry s...

Page 14: ...iameter or greater to allow proper gas volume to appliance If pipe is too small undue loss of volume will occur Installation must include an equipment shutoff valve union and plugged 1 8 NPT tap Locat...

Page 15: ...valve control valve and equip ment shutoff valve from gas supply piping system Pressures in excess of 1 2 psig 3 5 kPa will damage appliance regulator 2 Cap off open end of gas pipe where equip ment...

Page 16: ...ontrol accessories are available separately see Accessories Page 41 Read instructions shipped with remote control along with instructions below before attempting installation 1 If unit is already inst...

Page 17: ...your selector switch is in OFF posi tion before installing or chang ing batteries in your hand held remote or receiver Hand Held Remote Control The hand held remote control uses 3 AAA batteries not in...

Page 18: ...NE WARNING Failuretoposition thepartsinaccordancewiththese diagrams or failure to use only parts specifically approved with thisappliancemayresultinprop erty damage or personal injury Magniflame SERIE...

Page 19: ...Side View Figure 25 Installing Back Left Log Back Left Log D 060 D 018 or D026 Flat Part of Log Log Notch Burner Tube Figure 25A Installing Back Left Log Figure 25B Installing Back Left Log D 018 Rea...

Page 20: ...w Figure 27B Installing Charred Log Top Side View Square Grate Log Notch tube on the right side The left side of the burner tube fits into the notch on the back side of this log The log is placed prop...

Page 21: ...0GTA B or LMF30MOA B models D 023 LMF36GTA B or LMF36MOA B models D 029 SeeFigures31 and31A The left end of this log has a round hole that fitsovertheroundpegthatisonthetopofthe back left log The righ...

Page 22: ...l not be allowed to come in contact with either the burner ports or flame around base of appliance if desired DO NOT place rock or additional logs on front burner or on logs except as directed above P...

Page 23: ...control system and any gas control which has been under water LIGHTING INSTRUCTIONS WARNING Iffireplacehasglassdoors never operate this appliance with glass doors closed If you operate ap pliance with...

Page 24: ...e running this appliance for the first time after hooking up to gas supply If so the control knob may need to be pressed in for 30 seconds or more This will allow air to bleed from the gas system 7 Wi...

Page 25: ...turned off You can now turn burner on and off with hand held remote control unit IMPORTANT Do not leave selector switch in the REMOTE or ON position when pilot is not lit This will drain the battery...

Page 26: ...r Button Location O F F PILOT O N Control Knob Igniter Button 7 With control knob pressed in press and release igniter button This will light pilot The pilot is attached to the front burner If needed...

Page 27: ...helps distribute heated air from the fireplace NOTE Periodically check the louvers of the firebox and remove any dust dirt or other obstructions Figure 40 Pilot Natural Propane LP HAND HELD REMOTE OPE...

Page 28: ...mes through 5 levels see Figure 44 Select manual flame height function by press ing MODE button until a flame is shown in lower left corner of display Use UP DOWN arrow button to set desired flame hei...

Page 29: ...receiver face plate marked PRG The receiver will beep 3 times to indicate it is ready to accept a new remote transmitter Press the ON OFF button on your remote and the receiver will beep 4 times to co...

Page 30: ...ctor holder for dust and dirt see Figure 51 3 Blow air through the ports slots and holes in the burner 4 Check injector holder located at end of burner tube again Remove any large particles of dust di...

Page 31: ...MNF30INV Rating Variable 29 000 40 000 Btu Hr Type Gas Natural Ignition Electronic Manifold Pressure 3 4 W C Inlet Gas Pressure in of water Max 10 5 W C Min 5 W C For purpose of input adjustment To Th...

Page 32: ...Air in gas lines when in stalled 5 Depleted gas supply pro pane LP only 6 ODS pilot is clogged 7 Gas regulator setting is not correct REMEDY 1 Overlap ember material 1 4 see Page 22 1 Reconnect ignite...

Page 33: ...ol knob pressed in 30 seconds 3 Wait one minute for safety interlock system to reset Repeat ignition operation 4 Fully open equipment shut off valve 5 A Contact local natural or propane LP gas company...

Page 34: ...moved from line Have gas line checked by local natural or propane LP gas company 3 Observe minimum installa tion clearances see Pages 9 through 11 4 Clean burners see Clean ing and Maintenance Page 30...

Page 35: ...1 Gas leak See Warning statement at top of page 2 Control valve or gas control defective 1 Foreign matter between control valve and burner 2 Gas leak See Warning statement at top of page 1 Hand held r...

Page 36: ...M MNF24INV MNF24IPM MNF24IPV MNF30INM MNF30INV MNF30IPM MNF30IPV 2 1 3 4 5 6 7 8 9 31 32 33 11 30 12 13 14 15 16 17 18 19 10 20 21 22 23 24 25 26 27 34 28 29 Cat No Model F2088 MNF24INM F2091 MNF24IPM...

Page 37: ...xtension HI LO 1 9 J3562 Male Connector 1 10 J7716 Tube Inlet 1 11 J6364 Asm Pan Burner 1 12 J6147 Bracket Front Burner 2 13 J3547 Nut Captive Washer 2 14 J4886 Air Shutter 1 15 J6127 Orifice Holder 9...

Page 38: ...J6517 D 018 J6528 D 026 Log Back Left 1 3 J6698 D 059 J6518 D 017 J6529 D 025 Log Front Left 1 4 J6519 D 020 J6519 D 020 J6519 D 020 Log Charred 1 5 J6699 D 063 J6520 D 021 J6530 D 028 Log Middle Spl...

Page 39: ...on Page 40 of this manual KEY NO CAT NO Log Id CAT NO Log Id CAT NO Log Id DESCRIPTION QTY 1 J8245 D 061 J8253 D 019 J8259 D 027 Log Front Right 1 2 J8246 D 060 J8254 D 018 J8260 D 026 Log Back Left 1...

Page 40: ...air parts always give the following information 1 The model number of the appliance 2 The serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The i...

Page 41: ...easy chair EMBER KITS Platimun Embers Cat No J6207 Glowing Embers rockwool Cat No J6208 RECEIVER AND REMOTE CONTROL KIT Cat No F1077 MODEL MRC REMOTE READY MODELS ONLY For all models Allows the firep...

Page 42: ...______________ ______________________________________________________ ______________________________________________________ ______________________________________________________ ____________________...

Page 43: ...produce excessive temperatures and could result in a re hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product d da...

Page 44: ...liance model number Appliance serial number Date appliance was Installed Type of gas appliance uses Dealer name IHP reserves the right to make changes at any time without notice in design materials sp...

Reviews: