background image

13

WARRANTY

Your gas appliance is covered by a limited twenty 

year warranty. You will find a copy of the war-

ranty accompanying this manual.  Please read 

the warranty to be familiar with its coverage.

Retain this manual. File it with your other docu-

ments for future reference.

REPLACEMENT PARTS

A  complete  parts  list  is  found  at  the  end  of 

this manual. Use only parts supplied from the 

manufacturer.

With proper care and maintenance, your appli-

ance will provide many years of enjoyment. If 

you should experience any problem, first refer 

to the troubleshooting guide in this manual. 

If problem persists, contact your LHP dealer 

or distributor.

Normally, all parts should be ordered through 

your  LHP  distributor  or  dealer.  Parts  will  be 

shipped at prevailing prices at time of order.
When  ordering  repair  parts,  always  give  the 

following information:

1. The model number of the appliance.

2. The serial number of the appliance.

3. The part number.

. The description of the part.

5. The quantity required.

6. The installation date of the appliance.
If  you  encounter  any  problems  or  have  any 

questions  concerning  the  installation  or  ap-

plication of this system, please contact your 

dealer or distributor.

LHP

1508 Elm Hill Pike, Suite 108

Nashville, TN 37210

visit us at www.Lennox.com

1-800-9-LENNOX

PRODUCT REFERENCE INFORMATION

We recommend that you record the following 

important  information  about  your  fireplace.  

Please call LHP for the phone number of your 

nearest LHP dealer who will answer your ques-

tions or address your concerns. 

Your Fireplace's Model Number ___________________________________________

Your Fireplace's Serial Number ___________________________________________

The Date On Which Your Fireplace Was Installed ______________________________

The Type of Gas Your Fireplace Uses _______________________________________

Your Dealer's Name   ___________________________________________________  

WIRING DIAGRAMS

Wiring diagrams are provided here for reference 

purposes only.  This information is also provided 

on schematics attached directly to the appliance 

on a pullout panel located within the control 

compartment.

CAUTION:  LABEL ALL WIRES 

PRIOR TO DISCONNECTION WHEN 

SERVICING CONTROLS.  WIRING 

ERRORS CAN CAUSE IMPROPER 

AND DANGEROUS APPLIANCE 

OPERATION.

ATTENTION :  AU MOMENT DE 

L'ENTRETIEN DES COMMANDES, 

ÉTIQUETEZ TOUS LES FILS AVANT 

DE LES DÉBRANCHER.  DES 

ERREURS DE CÁBLAGE PEU-VENT 

ENTRAÎNER UN FONCTIONNEMENT 

INADÉQUAT ET DANGEREUX.

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Electronic Wiring Diagram 

(Honeywell) Showing Blower 

Wiring for Optional FBK-100, FBK-

200 & FBK-250 Kits

Schematic Representation Only

Relay Module C/W FBK-250 only. Plug blower  

into J-Box receptacle for FBK-100 or FBK-200  

application. See View A for J-Box wiring. 

Optional Blower 

*OFF/ON Switch  

(Integral with  

Gas Valve) 

Honeywell 

Electronic 

Gas 

Valve 

120 VAC 

Primary 

Secondary 

Optional Control Switch 

Junction Box 

Pilot Burner 

Assembly 

BL 

BL 

Field Wired
Factory 

Wired

BK = BLACK   BL = BLUE

R = RED         W = WHITE

G = GREEN

BK 

BK 

BK 

BL 

GROUND 

24 V 

Transformer 

       View A  

J-Box Wiring when  

using unit mounted  

relay module. 

BK 

C A 

V   

0 2 

Igniter 

Connector 

*  Leave the OFF/ON switch, which is 

integral with the gas valve, in the ON 

position.

**

Optional Control Switches

: Wall 

Switch, Wall Thermostat or Remote 

Control Receiver.

Notes:

1. If any of the original wire as supplied 

must be replaced, use Type AWM 105°C 

- 18 gage wire ONLY.

2. 120 VAC, 60 Hz - Less than 3 Amps.

Caution: label all wires prior to 

disconnection when servicing controls. 

Wiring errors can cause improper and 

dangerous operation.

Figure 15

TH

TP

TH

TP

 

 

 

 

Thermopile

If any of the original wire as 

supplied must be replaced, 

it  must  be  replaced  with 

Type  AWM105o  C  -  18 

gage wire.

*  Optional  Kits  Installed  -  OFF/ON  wall  switch,  wall 

thermostat  or  remote  control  receiver.  Note:  Turn  the 

appliance-mounted OFF/ON burner control switch to the 

OFF position if any of these kits are installed. 

Millivolt Wiring Diagram

Field Wired

Factory 

Wired

*Optional Switch

Standard OFF/ON Switch

Figure 14

Schematic Repre-

sentation Only

Summary of Contents for Millivolt SSDVPF-CNM-B

Page 1: ...phones se trouvant dans le b timent o vous trouvez Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur d...

Page 2: ...e Embers and Logs Page 9 Burner Flame Appearance Sooting Page 11 Burner Air Shutter Adjustments Page 12 Millivolt Appliance Checkout Page 12 Electronic Appliance Checkout Page 12 Warranty Page 13 Prod...

Page 3: ...ion is hot while in operation and for a period of time fol lowing the use of the fireplace Young children should be carefully supervised when they are in the same area as a hot termination To prevent...

Page 4: ...e Sizes Sea Level to High Altitude All Models These appliances are tested and approved for installation at elevations of 0 4500 feet 0 1372 meters above sea level using the standard burnerorificesizes...

Page 5: ...er may be turned ON and OFF using a wall switch remote control optionalonunitrockerswitch FRS or wall thermostat To operate Toggle the switch between its ON and OFF positions If your millivolt applian...

Page 6: ...located on the front of the valve refer to Figure 3 H I LO W H T P T H T P T P I L O T P I L O T O N i t OFF IN OUT Manifold Pressure Tap Inlet Pressure Tap Pilot Adjustment Screw HI LO Variable Flame...

Page 7: ...para controlar la chimenea encuentre el transmisor y l mpielo bien para quitar el polvo y aceite Pegue la etiqueta en la superficie del transmisor Figura C Seleccione el idioma que m s se habla en la...

Page 8: ...ch heating season depending on the circumstances present The following cleaning solutions are approved for use to clean glass Non ammonia based household cleaner 50 50 mix of white vinegar and water G...

Page 9: ...he control compartment To disengage the two latches from the bottom vee flange of the glass enclosure panel reach for the handles located towards the back of the latches and pull the handles down towa...

Page 10: ...he top of the pile of decorative volcanic stone Place a few quar ter sized pieces of the glowing ember material on the pan burner in front of the burned out area on both sides of the log set The glowi...

Page 11: ...urfaces adjacent to the vent termination Sooting is caused by incomplete combustion in the flames and lack of combustion air entering the air shutter opening To achieve a warm yellowish orange flame w...

Page 12: ...k or sooty adjust theairshutter incrementally toamore open position until the proper flame appearance is achieved If flame stays lowered blue adjust the air shutter incrementally to a more closed posi...

Page 13: ...s Wiringdiagramsareprovidedhereforreference purposesonly Thisinformationisalsoprovided onschematicsattacheddirectlytotheappliance on a pullout panel located within the control compartment CAUTION Labe...

Page 14: ...tes briefly to verify that a signal has been sent The Model RCL is designed to operate with all mil livolt ignition systems as well as electronic ignition systems It may be installed with use for eith...

Page 15: ...glass enclosure panel resulting in the appearance of a picture frame ref Form 750 098M 4 Piece Door Trim Kits Polished Brass Brushed Stainless Where Used Cat Model Cat Model 26M83 4DFK40PB 26M86 4DFK...

Page 16: ...e with these appliances Order kits as part of the periodic maintenance of the appliance Decorative Firebox Accessories all models Cat No ModelNo Description 88L53 FGE Bag of Glowing Embers 1 oz rockwo...

Page 17: ...ot touch any electric switch do not use any phone in your building TO TURN OFF GAS TO APPLIANCE 1 Turn remote wall switch OFF The pilot will remain lit for normal service 2 For complete shutdown turn...

Page 18: ...rer appelez un technicien qualifi Quiconque tente de forcer la manette ou de la r parer peut provoquer une explosion ou un incendie D N utilisez pas cet appareil s il a t plong dans l eau m me partiel...

Page 19: ...Electronic 1 For complete shut down turn remote wall switch to OFF 2 Open lower control compartment door 3 Turn the OFF ON switch to OFF Do not force 4 Close the main line shut off valve 5 Close lowe...

Page 20: ...que ON qui alimente l appareil interrupteur mural ou l appareil 9 Fermez la porte du compartiment de contr le du bas 10 Si l appareil ne fonctionne pas suivre les instructions intitul es Pour fermer l...

Page 21: ...s of the system being exposed to cold weather Also inspect wall straps or plumbers s tape to ensure it is secure and in place Appliance Checkout Qualified Service Technician Perform the appropriate ap...

Page 22: ...ch if burner comeson replacedefectivewallswitch Ifokay jumper wiresacrosswallswitchwiresatvalve ifburnercomes on wires are faulty or connections are bad B Thermopile may not be generating suf ficient...

Page 23: ...24V common leads to valve control Mustmeasureatleast19 5VACwith igniter powered see insert A To identifyproperlead thischeckmust be done with the valve control con nected and igniter powered NO Check...

Page 24: ...0K86 Piezo Igniter 1 SSDVST NM SSDVST PM 32 69L17 Pilot Assembly Natural Gas 1 SSDVST NM 32 69L18 Pilot Assembly Propane 1 SSDVST PM 33 60J79 Pilot Generator 1 SSDVST NM SSDVST PM 34 74L57 Thermocoupl...

Page 25: ...USTRATIONS ARE NOT TO SCALE REPLACEMENT PARTS DIAGRAMS Firebox Cabinet 1a 2a 3a a 8 10a 10b 37 13a 31 30 13b 16 12 12 7 17 1 1b 3b b 5 2b 11 32 33 3 36 35 0 30 3 1 5 2 6 Note Cabinet and Firebox shown...

Page 26: ...26 NOTES...

Page 27: ...27 NOTE DIAGRAMS ILLUSTRATIONS ARE NOT TO SCALE NOTES...

Page 28: ...rves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code...

Reviews: