Superior Maddalena Installation & Use Manual Download Page 7

USER OPERATING INSTRUCTIONS - WOOD 

 
Please read the important notices given above before referring to the main instruction book for detailed 
operating instructions. 
 

HETAS Ltd Approval 

HETAS approval may be limited to specific fuel types as detailed in the main instruction manuals.         
Approval does not cover the use of other fuels either alone or mixed with the recommended fuel, nor does 
it cover instructions for the use of other fuels. 
 

Recommended fuels 

Stoves may be designed to burn dry seasoned wood logs and/or solid mineral fuel as indicated in the 
main stove manuals. 
 

Door operation 

The door handle may become hot during operation, use the tool to open and close the doors, if  appropriate. 

Lighting of fire 

Place some firelighters or paper and dry kindling wood on the grate and cover with a small amount of fuel. 
Set air controls to maximum and set light to firelighters or paper. Close the doors and allow fire to burn 
until fuel is well alight then load with more fuel and adjust air controls to the required level of heat output. 
Before relighting the fire clean the firebed of ash and clinker and empty the ashpan. 
 

Refuelling 

Keep the firebox well filled (the fuel may be sloped up from the front firebars), but do not allow fuel to spill 
over the top of the front fire bars.  Take care that fuel does not project over the front fire bars or damage to 
the glass may be caused when the doors are closed 

 
Flueway cleaning 

It is important that the baffle plate and all the stove flueways are kept clean.  When burning smokeless 
fuels they should be cleaned at least monthly.  When burning other fuels they should be cleaned at least 
once a week, and more frequently if necessary. 
Remove any sooty deposits from the baffle plate until they fall off into the fire. 
More soot will be deposited on the baffle plate and in the flueways if the stove is run at low levels for long 
periods.  If this is the case then more frequent cleaning will be necessary. 
 

Cleaning and maintenance 

The instructions detailed in the section “Maintenance” in the instruction booklet should be followed. 
 

Spare Parts 

Spare parts can be obtained from Robeys Limited 01773 820 940 
 

Trouble shooting 

The instructions detailed in the relevant section in the instruction booklet should be followed together with 
the following additional items: 
 

1.  Fire Will Not Burn 

Check that: 
a)  the air inlet is not obstructed in any way, 
b)  that chimneys and flueways are clear, 
c)  that a suitable fuel is being used, 
d)  that there is an adequate air supply into the room, 
e)  that an extractor fan is not fitted in the same room as the fire. 

 

2.  Fire Blazing Out Of Control

 

Check that: 
a)  the doors are tightly closed, 
b)  the air control is turned down to the minimum setting, 
c)  the air inlet damper is closed and that it is not prevented from closing completely by a piece of ash, 
d)  a suitable fuel is being used, 
e)  the door seals are in good condition.

 

Summary of Contents for Maddalena

Page 1: ...1 ...

Page 2: ...e available for loading unloading and site handling Fire Cement Some types of fire cement are caustic and should not be allowed to come into contact with the skin In case of contact wash immediately with plenty of water Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate...

Page 3: ... fitted in place of an open fire then the chimney should be swept one month after installation to clear any soot falls which may have occurred due to the difference in combustion between the stove and the open fire If there is no existing chimney then either a prefabricated block chimney in accordance with Building Regulations Approved Document J or a twin walled insulated stainless steel flue to ...

Page 4: ...ithin this area Connection to chimney Stoves may have a choice of either a rear or top flue gas connector that allows connection to either a masonry chimney or a prefabricated factory made insulated metal chimney in accordance with their instructions In some cases it may be necessary to fit an adaptor to increase the diameter of the flue to the minimum required 150 mm section of the chimney or lin...

Page 5: ... the appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above Use of fireguard When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with the stove The fireguard should be manufactured in accordance with BS 8423 2002 Replaces BS 6539 If the fire is left unattended a sp...

Page 6: ...rected in the instructions Dampers left open Operation with the air controls or dampers open can cause excess smoke The appliance must not be operated with air controls or dampers left open except as directed in the instructions Periods of Prolonged Non Use If the stove is to be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel resi...

Page 7: ...rs or damage to the glass may be caused when the doors are closed Flueway cleaning It is important that the baffle plate and all the stove flueways are kept clean When burning smokeless fuels they should be cleaned at least monthly When burning other fuels they should be cleaned at least once a week and more frequently if necessary Remove any sooty deposits from the baffle plate until they fall of...

Page 8: ...8 ...

Page 9: ...TIFICATION DATA 21 2 6 DIMENSIONS VERA 21 2 7 DIMENSIONS VITTORIA 22 2 8 DIMENSIONS VITTORIA WITH SEAT 22 3 0 PREPARING FOR INSTALLATION 23 4 0 USE 24 4 1 FUEL 24 4 2 COMBUSTION AIR REGULATION 25 4 3 LIGHTING FOR THE FIRST TIME 25 4 4 LIGHTING 25 4 5 OPENING THE DOOR 25 4 6 NIGHT TIME OPERATION AT MINIMUM 25 4 7 OPERATING UNDER ADVERSE WEATHER CONDITIONS 26 4 8 OVERHEATING AND EXTINGUISHING 26 5 0...

Page 10: ...10 N O T F O R U K U S E ...

Page 11: ...11 ...

Page 12: ...12 ...

Page 13: ...13 N O T F O R U K U S E ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...16 N O T F O R U K U S E ...

Page 17: ...17 N O T F O R U K U S E ...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...20 ...

Page 21: ...21 ...

Page 22: ...22 ...

Page 23: ...23 ...

Page 24: ...24 ...

Page 25: ...25 ...

Page 26: ...26 ...

Page 27: ...27 ...

Page 28: ...28 ...

Page 29: ...29 ...

Page 30: ...30 ...

Page 31: ...31 ...

Page 32: ...32 ...

Page 33: ...33 ...

Page 34: ...34 Riverside Goods Road Belper Derbyshire DE56 1UU Tel 01773 820940 Fax 01773 820477 E mail info robeys co uk Web Site www robeys co uk ...