background image

1

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

FOR YOUR SAFETY:  Do not store or use gasoline
or other flammable vapors or liquids in the vicin-
ity of this or any other appliance.

FOR YOUR SAFETY:  What to do if you smell gas:

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a

neighbor’s phone.

Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the

fire department.

Installation and service must be performed by a
qualified installer, service agency or the gas
supplier.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAM-
AGE, PERSONAL INJURY OR LOSS OF LIFE.

POUR VOTRE SÉCURITÉ:  Ne pas entreposer ni utiliser
d'essence ni d'autre vaperurs ou liquides inflammables
dans le voisinage de cet appareil ou de tout autre
appareil.

POUR VOTRE SÉCURITÉ:  Que faire si vous sentez une
odeur de gaz:

• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur.  Ne pas vous servir

des téléphones se trouvant dans le batiment où
vous vous trouvez.

• Evacuez la piéce, le bâtiment ou la zone.
• Appeflez immédiatement votre fournisseur de gaz

depuis un voisin.  Suivez les instructions du
fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service dos incendies.

L'installation et service doit être exécuté par un qualifié
installer, agence de service ou le fournisseur de gaz.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE
LES INSTRUCTIONS DONNÉ DANS CETTE NOTICE POUR
RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU
POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE
BLESSURE OU LA MORT.

B-VENT

GHC/GRD-5500 SERIES

MODELS

HOMEOWNER'S CARE AND
OPERATION INSTRUCTIONS

WH Report No. J20046562

B-VENTED GAS FIREPLACES
P/N 725,029M  REV.  C  07/2004

t

l

o

v

i

l

l

i

M

s

l

e

d

o

M

c

i

n

o

r

t

c

e

l

E

s

l

e

d

o

M

N

0

0

5

5

-

C

H

G

2

-

E

N

0

0

5

5

-

C

H

G

P

0

0

5

5

-

C

H

G

2

-

E

P

0

0

5

5

-

C

H

G

N

0

0

5

5

-

D

R

G

2

-

E

N

0

0

5

5

-

D

R

G

P

0

0

5

5

-

D

R

G

2

-

E

P

0

0

5

5

-

D

R

G

GRD-5500 SHOWN

Summary of Contents for GHC-5500N

Page 1: ...t autre appareil POUR VOTRE S CURIT Que faire si vous sentez une odeur de gaz Ne pas tenter d allumer d appareil Netouchez aucuninterrupteur Nepasvousservir des t l phones se trouvant dans le batiment...

Page 2: ...rate these units Installation must conform to local codes In the absence of local codes installation must comply with the current National Fuel Gas Code ANSI Z223 1 NFPA 54 In Canada the currentCAN CG...

Page 3: ...VELY PRESSUREDENVIRONMENTS PRESSURE WITHIN THE HOME IS LESS THAN PRES SURES OUTSIDE SIGNIFICANT NEGA TIVELY PRESSURED ENVIRONMENTS CAUSED BY WEATHER HOME DESIGN OR OTHER DEVICES MAY IMPACT THE OPERATI...

Page 4: ...n be used with an optional remote control kit The appliance main burner may be turned on and off with the wall switch or remote control Electronic Appliance Lighting To light electronic appliances ref...

Page 5: ...back on The appliance should then relight and remain lit If this does not occur turn off the appli ance and call a qualified service technician Burner Adjustments Flame Appearance and Sooting Proper f...

Page 6: ...Accomplishing Person Procedure Inspecting Cleaning Burner Logs and Controls Check Flame Patterns and Flame Height Inspecting Cleaning Pilot and Burner Checking Vent System Appliance Checkout Replacin...

Page 7: ...f a higher than normal temperature is sensed due to a blocked vent or prolonged downdraft the limit switch will open and cause the burner to shut off The pilot flame should be steady not lifting or fl...

Page 8: ...AUTION THESE CERAMIC FIBER LOGS MUST BE HANDLED CAREFULLY THEY WILL STAND UP INDEFINITELY TO EX TREMETEMPERATURES HOWEVER THEY ARE VERY FRAGILE AND ARE SUSCEP TIBLE TO CRUSHING AND OR BREAKAGE IF HAND...

Page 9: ..._________ The Type of Gas Your Fireplace Uses ___________________________________ Your Dealer s Name_________________________________________________ When ordering repair parts always give the followi...

Page 10: ...e safety information above on this page If you do not smell gas go to the next step 7 Push in gas control knob slightly and turn counterclockwise to PILOT 8 Push in control knob all the way and hold i...

Page 11: ...ontre jusqu la position d arr t OFF Ne forcez pas le bouton 5 Fermez le compartiment de contr le du bas 8 Enfoncez le bouton de r glage jusqu au fond et gardez le enfonc Allumez imm diatement la veill...

Page 12: ...ely call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water LIGHTING INSTRUCTIONS ELECTRONIC 1 For com...

Page 13: ...lageoucommandedugazquia t sous l eau 1 ARR TEZ Lisez les consignes de s curit au verso de cette plaque 2 Tournez l interrupteur mural la position d arr t OFF 3 Ouvrez la porte du compartiment de contr...

Page 14: ...mpingement on generator Be sure wire connections from generator at gas valve terminals are tight and generator is fully inserted into the pilot bracket One of the wall switch wires may be grounded Rem...

Page 15: ...niter is sparking at the pilot assembly when the ON OFF switch is activated If not undertake the following steps With ON OFF switch OFF remove wire at TR terminal at the ignition control module Discon...

Page 16: ...with a variable speed wall switch Horizontal Trim Installation There are two 2 optional horizontal trim kits Models 35HTK PB 35HTK SPB available for use with the GHC Series appliance The 35 HTK SPB ki...

Page 17: ...1 1 d t f e L p o T g o L 1 0 2 3 M 3 1 1 1 0 2 3 M 3 1 1 0 1 y l b m e s s A r e n r u B 1 5 2 4 4 0 1 1 5 2 4 4 0 1 1 1 l l a W h c t i w S l o r t n o C F F O N O 2 7 9 5 2 0 1 2 7 9 5 2 0 1 2 1 t...

Page 18: ...18 NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE REPLACEMENT PARTS MILLIVOLT 12 13 13 23 11 22 20 24 26 25 14 At Rear of FireBox 14 At Rear of FireBox 10 7c 7d 7a 7b...

Page 19: ...l b m e s s A r e n r u B 1 5 2 4 4 0 1 1 5 2 4 4 0 1 1 1 l l a W h c t i w S l o r t n o C F F O N O 2 7 9 5 2 0 1 2 7 9 5 2 0 1 2 1 t n o r F r e v o C 1 0 8 5 2 0 1 1 0 8 5 2 0 1 3 1 n o i s n e t...

Page 20: ...o make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your local distributor for fireplace code information 111...

Reviews: