Superior FVDR18 Installation And Operation Instructions Manual Download Page 7

www.SuperiorFireplaces.US.com

126904-01A

7

CHECK GAS TYPE

Use only natural gas. If your gas supply is not 

natural gas, you must install ON/OFF Safety 

Valve/Pilot  Kit  (see 

Accessories

,  page  24). 

Call dealer where you bought log set.
If the fireplace does not have a gas supply 

shutoff valve, one must be installed.

VENTING SPECIFICATIONS FOR 

INSTALLATION

The fireplace chimney flue and vent must be 

drafting properly. To check the vent for proper 

drafting: Light a tightly rolled newspaper on 

one end and place it at the inside front edge 

of the fireplace. Observe the smoke and be 

sure  the  vent  is  properly  drawing  it  up  the 

chimney. If the smoke spills out into the room, 

extinguish the flame and remove any obstruc

-

tion until proper venting is achieved.
The chimney flue must remain open a mini

-

mum of 3" at all times during the operation 

of this log set.

For Massachusetts Residents Only

Installation of this vented gas log set in the 

Commonwealth  of  Massachusetts  requires 

the  damper  be  permanently  removed  or 

welded in the fully open position.

INSTALLING DAMPER CLAMP

Secure the damper stop clamp provided to 

the leading edge of the damper as shown in 

Figure 3. If for any reason this clamp doesn't 

work on your fireplace, another suitable clamp 

or permanent stop must be installed, or the 

damper blade must be cut or removed.

INSTALLATION

Continued 

Damper 

Clamp

Damper 

Clamp

Damper

Manufactured 

Fireplace

Masonry Fireplace

Figure 3 - Attaching Damper Clamp

Damper

CONNECTING TO GAS SUPPLY

 WARNING: A qualified ser

-

vice person must connect log 

set to gas supply. Follow all 

local codes.

Installation Items Needed

Before installing log set, make sure you have 

the items listed below.
•  piping (check local codes)
•  sealant (resistant to Propane/LP gas)
•  equipment shutoff valve
•  test gauge connection
•  adjustable (crescent) wrench or pliers
•  sediment trap
•  tee joint
•  pipe wrench

  CAUTION:  Use  only  new, 

black iron or steel pipe. Inter-

nally-tinned copper tubing may 

be used in certain areas. Check 

your local codes. Use pipe of 

1/2" diameter or greater to allow 

proper gas volume to log set. If 

pipe is too small, undue loss of 

volume will occur.

Installation must include a equipment shutoff 

valve, union, and plugged 1/8" NPT tap. Lo

-

cate NPT tap within reach for test gauge hook 

up. NPT tap must be upstream from log set 

(see Figure 4, page 8).

IMPORTANT:

 Install equipment shutoff valve 

in  an  accessible  location.  The  equipment 

shutoff valve is for turning on or shutting off 

the gas to the appliance.
Apply pipe joint sealant lightly to male NPT 

threads. This will prevent excess sealant from 

going into pipe. Excess sealant in pipe could 

result in a clogged burner injector.

 WARNING: Use pipe joint 

sealant that is resistant to liquid 

petroleum (LP) gas.

Summary of Contents for FVDR18

Page 1: ...ed Refer to the National Fual Gas Codes ANSI Z233 1 NFPA 54 Section 5 3 for Combustion and Ventilation WARNING If the information in these instructions is not followed exactly a fire or explosion may...

Page 2: ...on must be made by a licensed plumber or gas fitter in the Commonwealth of Massachusetts WARNING Thisproductcon tainsand orgenerateschemicals known to the State of California to cause cancer or birth...

Page 3: ...nce SAFETY Continued Appliance assembly becomes very hot when in use Keep chil dren and adults away from hot surfacetoavoidburnsorclothing ignition Appliancewillremainhot for a time after shutdown All...

Page 4: ...o help prevent breakage new logs must be broken in see Curing Logs page 14 11 Turn log set off and let cool before servic ing installing or repairing Only a qualified service person should install ser...

Page 5: ...em may be connected to a wall switch or hand held wireless remote control See Accessories page 24 REMOTE CONTROL ACCESSORIES There is an optional hand held ON OFF re mote control that can be purchased...

Page 6: ...6 27 18 18 INSTALLATION Continued NOTICE Installation service andrepairofthisappliancemust be performed by a qualified in staller serviceagency company orgassupplierexperiencedwith this type of gas ap...

Page 7: ...op must be installed or the damper blade must be cut or removed INSTALLATION Continued Damper Clamp Damper Clamp Damper Manufactured Fireplace Masonry Fireplace Figure 3 Attaching Damper Clamp Damper...

Page 8: ...use an open flame to check for a leak Applyanoncorrosiveleakdetec tion fluid to all joints Bubbles forming show a leak Correct all leaks at once PRESSURE TESTING GAS SUPPLY PIPING SYSTEM Test Pressur...

Page 9: ...ting through hole and into burner manifold see Fig ure 6 Tighten using a wrench If using propane LP gas see Propane LP Gas Conversion page 11 6 Using burner clamp screw and nut pro vided assemble clam...

Page 10: ...ion Natural Gas Installation 1 Thread gas control valve onto burner inlet fitting see Figure 8 Use thread sealant on male threads of burner inlet fitting Hold burner inlet fitting with a wrench to pre...

Page 11: ...is supplied with orifice installed for a 24 log set If you have an 18 or 30 set you must change this orifice also See Figure 1 page 5 for product identification Burner Inlet Fitting 1 Remove burner in...

Page 12: ...nection s using pipe joint compound until burner system is leak free 4 When burner is tested and leak free observe individual tongues of flame on burner Note Burner design includes more ports on the o...

Page 13: ...TION Continued Figure 16 Installing Front and Back Logs Number and style may vary 5 Place smaller top logs onto bottom logs see Figure 17 Leave as much open space between logs as possible to mini mize...

Page 14: ...el Gas Codes ANSI Z233 1 NFPA 54 Air for Combustion and Ventilation If you don t smell gas go to the next step 5 Turn control knob counterclockwise to the PILOT position and press in Keep control knob...

Page 15: ...ough 7 page 14 8 Turn control knob counterclockwise to the ON position Burner should light If burner does not light call a quali fied service person 9 To leave pilot lit and shut off burners only turn...

Page 16: ...y cleaned and checked 3 Separate the logs to allow more flame passage 4 Remove any foreign items from the flame pattern and or check for proper orifice sizing 5 Preheat flue in very cold weather 1 Rel...

Page 17: ...pment shutoff valve 2 Turn control knob to PILOT position 3 Press in control knob while in PILOT position 4 Continue holding down control knob Repeat ignit ing operation until air is removed 5 Adjust...

Page 18: ...et burning vapors from paint hair spray glues cleaners chemi cals new carpet etc See IMPORTANT statement above 2 Gas leak See Warning statement at top of page 1 Gas leak See Warning statement at top o...

Page 19: ...iginal replacement parts This will protect your warranty coverage for parts replaced under warranty PARTS UNDER WARRANTY Contact authorized dealers of this product If they can t supply original replac...

Page 20: ...03 901064 02 901064 03 901064 04 Natural Gas Injector 1 5 901208 01 901208 02 901207 01 901207 02 901207 03 Burner Manifold 1 6 Burner Pan 1 7 901242 01 901242 01 901242 01 901242 01 901242 01 Damper...

Page 21: ...Bottom Front Log VCB 13 1 901123 02 Bottom Front Log VCB 14 1 901123 03 Bottom Front Log VCB 16 1 3 901122 01 Bottom Front Log VCB 11 1 901122 02 Bottom Front Log VCB 12 1 901122 03 Bottom Front Log V...

Page 22: ...1 8 901126 01 Top Log FS 15 1 9 901131 01 Top Log FR 14 1 10 901458 01 Bottom Rear Log CR 16 1 901458 02 Bottom Rear Log CR 20 1 11 901459 01 Bottom Front Log CPR 18 1 901459 02 Bottom Front Log CPR...

Page 23: ...PR 13S 1 4 118040 01 Bottom Log FA 19 1 5 118038 01 Bottom Log FA 9 1 6 118041 01 Bottom Log FA 12 1 F A 1 8 F A 2 4 F A 3 0 1 4 2 3 5 6 Appalachian Oak Logs PARTS LOG SET MODELS FA18 FA24 AND FA30 Th...

Page 24: ...on INDIVIDUAL ROUND LOG GA9450A For decorative purposes only Not to be used as additional logs on unit Purchase these accessories from your local dealer If they can not supply these accessories call I...

Page 25: ...ll produce excessive temperatures and could result in a fire hazard c damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product...

Page 26: ...located on product or identification tag ______________________________ Serial No located on product or identification tag ___________________________ Date Purchased ___________________________ Keep...

Page 27: ...___________________ ______________________________________________________ ______________________________________________________ ______________________________________________________ _______________...

Page 28: ...126904 01 Rev A 02 14 1508 Elm Hill Pike Suite 108 Nashville TN 37210 1 800 655 2008 www IHP US com P126904 01...