Superior DXS3030TMN Installation And Operation Manual Download Page 20

20

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

Operating Instructions

Pre-Lighting Checklist

Be sure to check these items before the initial lighting of the 

stove:

c  

The stove gas label corresponds to the gas supply available 

- that is “natural gas” for natural gas or “LP gas” for LP 

gas.

c  

Gas pressure has been checked carefully - see 

Page 18

.

c  

All gas fittings have been checked for leaks.

c  

All clearances to combustibles have been met - see 

Page 

10

.

c  

All combustible materials have been removed from area in 

front of the stove.

c  

All vented areas of the stove are unobstructed.

c  

House is ventilated to clear initial paint curing odors - see 

Page 22

.

c  

All packaging materials have been removed from the fire-

box.

c  

While stove is cool, fingerprints or other marks have been 

cleaned from any gold or nickel surfaces with denatured 
alcohol and a soft cloth. Marks left on these surfaces may 
become etched into the finish if not removed prior to burning 
the unit.

c   

Brick panel, log set and embers have been installed.

c  

The glass door is in place and is properly sealed.

Lighting Instructions

CAUTION:  HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP 

CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH 

FLAMMABLE VAPORS AWAY. NEVER OPERATE UNIT WITH GLASS 
OFF OR ATTEMPT TO REMOVE THE GLASS WHILE HOT.

CAUTION: YOUR IHP GAS APPLIANCE MUST ALWAYS BE OPER-
ATED WITH GLASS IN PLACE.

The following is a copy of the operating and lighting instructions 

found with each stove:

FOR YOUR SAFETY READ BEFORE LIGHTING

WHAT TO DO IF YOU SMELL GAS:

•   DO NOT

 try to light the appliance.

 

•   DO

 

NOT

 touch any electric switch

do not use any phone in 

your building.  

•  

Immediately call your gas supplier from a neighbor’s phone. 
Follow the gas supplier’s instructions. 

•  

If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. 

Never use tools. If the knob will not push in or turn by hand, 
don't try to repair it, call a qualified service technician. Force 
or attempted repair may result in a fire or explosion.

D. 

DO NOT

 use this appliance if any part has been under water. 

Immediately call a qualified service technician to inspect the 
appliance and to replace any part of the control system and any 
gas control which has been under water.

LIGHTING INSTRUCTIONS

1.  

STOP!! Read the safety information on this page before 
proceeding.

2. (If applicable) Set the thermostat to lowest setting. Turn wall 

on/off switch, unit mounted on/off switch or remote control 

switch “OFF.”

3. Turn off ALL electrical power to the appliance.
4.  Open the lower door to access control compartment. Make sure 

gas supply shut-off cocks are open. 

5. Push in gas cock dial slightly and turn clockwise                 to 

“OFF.”

 

NOTE

:  Dial cannot be turned from “PILOT” to “OFF” unless 

dial is pushed in slightly. Do not force.

6. Wait five (5) minutes to clear out any gas. Then smell for gas, 

including near the floor. If you smell gas, STOP! Follow “B” on 

this page. If you don’t smell gas, go to the next step.

7. Locate the pilot by looking over the top of the left front log. A 

blue flame will be seen when the pilot is lit.

8. Turn the gas control knob counterclockwise               to the 

"PILOT" position.

9.   Push in control knob all the way and hold in. Immediately light 

the pilot by triggering the piezo igniter (pushing the button) 
until pilot lights. Continue to hold the control knob in for about 
1-1/2 minutes after the pilot is lit. Release knob and it will pop 
back out. Pilot should remain lit. If it goes out, repeat steps 
5-9. 

•  If knob does not pop up when released, stop and immediately 

call your service technician or gas supplier.

•  If the pilot will not stay lit after several tries, turn the gas 

control knob to “OFF” and call your service technician or 

gas supplier.

A. This appliance is equipped with a piezo ignition device to light the 

pilot. When lighting the pilot, follow these instructions exactly.

B.

 BEFORE LIGHTING,

 smell around the appliance area for gas. 

Be sure to smell next to the floor because some gas is heavier 

than air and will settle on the floor.

WARNING:  IF YOU DO NOT FOLLOW THESE INSTRUCTIONS 

EXACTLY,  A  FIRE  OR  EXPLOSION  MAY  RESULT  CAUSING 
PROPERTY DAMAGE, INJURY, OR LOSS OF LIFE.

Summary of Contents for DXS3030TMN

Page 1: ...les instructions du fournis seur Si vous ne pouvez rejoindre le fournisseur de gaz appelez le service des incindies L installation et l entretien doivent tre assur s par un installateur ou un service...

Page 2: ...Residential and Mobile Home Installations 13 Vent Considerations 13 Vent Parts List 14 Horizontal Vent Installation 14 Vertical Vent Installation 15 Flue Restrictors 15 Horizontal Terminations 16 Vert...

Page 3: ...aller service agency or the gas supplier WARNING Failure to comply with these installation instructions will result in an improperly installed and operating appliance voiding its warranty Any change t...

Page 4: ...nected to a chimney or flue serving a separate solid fuel burning appliance These appliances are vented gas appliances Do not burn wood or other material in these appliances This appliance is only for...

Page 5: ...pag ndola Limpiebienlaplacadelinterruptoroeltermostatode paredparaquitarelpolvoyaceite Peguelaetiqueta enlasuperficiedelaplacadelinterruptorquecontrola la chimenea Figura A o en el termostato de pared...

Page 6: ...ppliance Has been certified for use with either natural gas or propane Is not for use with solid fuels Is approved for sitting rooms and or bedrooms THE GAS STOVE ORIFICE SIZE ALTITUDE ADJUSTMENT For...

Page 7: ...accordance with local codes or in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition or the Canadian Electrical Code CSA C22 1 latest edition NEW YORK CITY NEW Y...

Page 8: ...Determine the minimum clearance to combustibles from the rear of the unit to the wall It is also important to note the thickness of the wall Before cutting the vent hole through the wall make sure th...

Page 9: ...ty hazard The IHP warranty will be voided if one of the following occurs Installation of any damaged stove or vent system component Unauthorized modification of the direct vent system Installation oth...

Page 10: ...tween the alcove side walls is 51 1295mm The minimum height of the alcove is 46 1168mm and the maximum depth is 35 889mm Floor Protection A non combustible hearth pad is not required This stove may be...

Page 11: ...s or they will snap the studs off To install the spring handle first close the door and screw the handle into the receiving nut Then spray a household glass cleaner or water on the shaft of the handle...

Page 12: ...e logs are not properly installed your appliance will not function correctly Parts list rear log right log left log center log brick panel packaged separately 1 Remove the logs from the box and carefu...

Page 13: ...on of the direct vent system Installation of any vent component part not approved or manufactured by the approved vent manufacturer Installation other than as instructed by IHP and vent manufacturers...

Page 14: ...inals may not be recessed into a wall or siding 1 Set the unit in the desired location Check whether or not wall studs are in the way when the venting system is attached If wall studs are in the way y...

Page 15: ...and note which restrictor setting is recommended The flue restrictor is shipped in the firebox of your stove To install the restrictor see Figure 18 Remove the two 5 32 allen head screws A below Using...

Page 16: ...35 LP 0 3 horizontal 14 Snorkel Required No Light Obstructor DXS3030TMN 35 NG 0 3 horizontal 14 Snorkel Required No Light Obstructor Offsets must remain within maximum and minimum lines To install th...

Page 17: ...ded above meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly 3 feet 91 cm within a height of 15 feet above the meter regulator assembly I Clearance to...

Page 18: ...to the right of the inlet tap To check manifold pressure with the appliance burning at the high burn setting insert a small flat bladed screwdriver into the tap and turn a half turn counterclockwise C...

Page 19: ...e been furnished with the fireplace be affixed to the operation and control points of the fireplace per the instructions on Page 5 It is the installers responsibility to ensure these warnings are prop...

Page 20: ...cian Force or attempted repair may result in a fire or explosion D DO NOT use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance a...

Page 21: ...cause the flames to turn orange sooner may result in poor combustion sooting and a hazardous situation See the drawing to the right showing proper flame appearance When testing for proper operation If...

Page 22: ...sound of rush ing air may be heard The blower sounds may be reduced by adjusting the speed control located on the blower assembly Also a slight clicking soundmaybeheardasthegasvalveorblowerswitchistu...

Page 23: ...ing the thermostat or remote control and set the thermostat or remote control to the lowest temperature when you wish to use the rocker switch only otherwise one may override the other Millivolt Contr...

Page 24: ...pile and thermocouple and extend across the main burner tube ports Be careful not to back the screw out of its threads o Check that the area around the stove is kept clear and is free of combustible m...

Page 25: ...cleaner with ammonia on the door and glass gasket as it may dis solve the gasket glue Repair If the glass is broken in the glass door the entire door metal frame gasket and glass should be replaced a...

Page 26: ...ocess 2 Remove the log set see Log Installation 3 Remove the two phillips head screws from the back of the burner 4 Lift the right end of the burner and slide if off the orifice and shutter tube Remov...

Page 27: ...n pilot position for 1 2 minutes and light Check for spark at electrode and pilot if no spark and electrode wire is properly connected replace igniter See Lighting Instructions Pilot will not stay lit...

Page 28: ...des commandes tiquetez tous les fils avant de les d brancher Des erreurs de c blage peuvent entra ner un fonctionnement inad quat et dangereux Figure 31 BLOWER Female Spade 1 4 Female Spade 1 4 Femal...

Page 29: ...nform ment ces sch mas et ou si des pi ces autres que celles sp cifiquement approuv es avec cet appareil sont utilis es Contact an IHP dealer to obtain any of these parts WARNING Never use substitute...

Page 30: ...r may be wall mounted or placed in the valve compartment Cost Effective Solution Simple On Off operation Workswithmillivoltandlowvoltageelectronic ignition controls Kit includes Remote and Receiver Wa...

Page 31: ...5 000 23 500 25 000 17 500 25 000 18 000 MANIFOLD PRESSURE IN WC 3 5 10 0 3 5 10 0 MIN INLET PRESSURE IN WC 5 0 11 5 0 11 ORIFICE DMS 0 2 000 FT 0 610 M 34 111 IN 50 070 IN 42 093 IN 53 059 IN UNIT FA...

Page 32: ...tactez un installateur qualifi un agent de service ou un fournisseur de gaz Si vous op rez cet appareil sans qu il ne soit correctement raccord un conduit d vacuation vous pourriez risquer d tre empoi...

Page 33: ...ural or propane gas only Burning conventional fuels such as wood coal or any other solid fuel will cause damage to the Product will produce excessive temperatures and could result in a fire hazard c d...

Page 34: ...e serial number of the appliance 3 The part number 4 The description of the part 5 The quantity required 6 The installation date of the appliance If you encounter any problems or have any questions co...